Clinical Trials Logo

Clinical Trial Summary

The study is an open-label, randomized, two-period, one-way crossover study using the Meal Tolerance Test (MTT) protocol or the daily life setting protocol.

The study consists of two parts. Subject may participate in both parts or just in one part.

The first part tests the effect of local heating on the post prandial glucose levels following a bolus at in-patient settings.Type I and type II diabetic patients on basal bolus insulin therapy admitted after overnight fast for a meal tolerance test. Subjects injected 0.2 units/kg and consumed standardized liquid meal. Blood samples for glucose and insulin measurements was taken from a venous line. The study was conducted twice with (test) and without (control) the use of the InsuPad device.

The second part evaluate the safety and efficacy of the device use at daily life settings. Type I and type II diabetic patients enrolled to the study. They will be required to perform at least 3 self monitored blood glucose (SMBG) measurements. Study length is up to 25 months. Up to one month run in period, up to 12 months with the device (test) and up to 12 months without the device (control).The subjects will be asked to record events of hypoglycemia, hyperglycemia and any adverse events related to diabetes or the study.


Clinical Trial Description

The effect of the InsuPad device was studied using the Meal Tolerance Test protocol or the daily life setting protocol. In the Meal Tolerance Test protocol subjects consumed a standardized liquid meal taken immediately after injection of insulin bolus (0.2 units/kg body weight). Each subject went through the same Meal Tolerance Test protocol twice, once with the InsuPad device (test conditions) and again without the InsuPad device (control conditions) in randomized order. The study started after an overnight fast and stabilization period in which the subject glucose level was stabilized between 100-150 mg/dl, using I.V glucose solution/oral glucose or intravenous insulin administration if needed. The patient remained stable (change of glucose level <20mg/dl) without any intervention or infusion 30 min prior to the study. Blood glucose measurements were taken from a peripheral venous at pre-specified time points. Total follow up time was 5 hours post meal. Safety limits of the study were 75 mg/dl as the low limit and 300 mg/dl as the high limit. If the subject's blood glucose level was below 75 mg/dl glucose solution was given orally to increase his blood glucose level. If subjects blood glucose was above 300 mg/dl iv insulin was given to reduce blood glucose level.

In the daily life setting protocol subjects meeting the inclusion exclusion criteria enrolled to the study. Study length was up to 25 months. Up to one month run in period, up to 12 months with the device (test) and up to 12 months without the device (control). Subjects were asked to perform at least 3 blood glucose measurements a day. Subjects were asked to fill logbooks with measured blood glucose levels and insulin doses given during the whole study. Subjects were asked to report any adverse event during the study. The subjects received a tutorial about the device usage and the study procedures. The order of the test and control phases was randomly selected. ;


Study Design

Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Crossover Assignment, Masking: Open Label, Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT02306343
Study type Interventional
Source Insuline Medical Ltd.
Contact Gabriel Bitton, Ph.D.
Phone +972-52-4800249
Email gabby@insuline-medical.com
Status Recruiting
Phase N/A
Start date November 2011
Completion date September 2015

See also
  Status Clinical Trial Phase
Completed NCT03743779 - Mastering Diabetes Pilot Study
Completed NCT03786978 - Pharmaceutical Care in the Reduction of Readmission Rates in Diabetes Melitus N/A
Completed NCT01804803 - DIgital Assisted MONitoring for DiabeteS - I N/A
Completed NCT05039970 - A Real-World Study of a Mobile Device-based Serious Health Game on Session Attendance in the National Diabetes Prevention Program N/A
Completed NCT04507867 - Effect of a NSS to Reduce Complications in Patients With Covid-19 and Comorbidities in Stage III N/A
Completed NCT04068272 - Safety of Bosentan in Type II Diabetic Patients Phase 1
Completed NCT03243383 - Readmission Prevention Pilot Trial in Diabetes Patients N/A
Completed NCT03730480 - User Performance of the CONTOUR NEXT and CONTOUR TV3 Blood Glucose Monitoring System (BGMS) N/A
Recruiting NCT02690467 - Efficacy, Safety and Acceptability of the New Pen Needle 34gx3,5mm. N/A
Completed NCT02229383 - Phase III Study to Evaluate Safety and Efficacy of Added Exenatide Versus Placebo to Titrated Basal Insulin Glargine in Inadequately Controlled Patients With Type II Diabetes Mellitus Phase 3
Completed NCT05799976 - Text Message-Based Nudges Prior to Primary Care Visits to Increase Care Gap Closure N/A
Completed NCT06181721 - Evaluating Glucose Control Using a Next Generation Automated Insulin Delivery Algorithm in Patients With Type 1 and Type 2 Diabetes N/A
Recruiting NCT04489043 - Exercise, Prediabetes and Diabetes After Renal Transplantation. N/A
Withdrawn NCT03319784 - Analysis for NSAID VS Corticosteroid Shoulder Injection in Diabetic Patients Phase 4
Completed NCT03542084 - Endocrinology Auto-Triggered e-Consults N/A
Completed NCT02229396 - Phase 3 28-Week Study With 24-Week and 52-week Extension Phases to Evaluate Efficacy and Safety of Exenatide Once Weekly and Dapagliflozin Versus Exenatide and Dapagliflozin Matching Placebo Phase 3
Recruiting NCT05544266 - Rare and Atypical Diabetes Network
Completed NCT01892319 - An International Non-interventional Cohort Study to Evaluate the Safety of Treatment With Insulin Detemir in Pregnant Women With Diabetes Mellitus. Diabetes Pregnancy Registry
Completed NCT05031000 - Blood Glucose Monitoring Systems: Discounter Versus Brand N/A
Recruiting NCT04039763 - RT-CGM in Young Adults at Risk of DKA N/A