Clinical Trials Logo

Clinical Trial Summary

The purpose of the study is to assess the safety and efficacy of the Imperial College Microprobe Array Continuous Glucose Sensor in healthy volunteers and in subjects with type 1 diabetes.


Clinical Trial Description

Continuous knowledge of ambient glucose levels will be of benefit to patients with T1DM, especially those with troublesome hypoglycaemia. Existing monitors require skin puncture to access interstitial fluid and sense its glucose content. Despite their clinical benefits, their use is associated with discomfort and their accuracy is questionable in hypoglycaemia. The development of a painless continuous glucose monitor is regarded as the top research priority by patients with diabetes. A novel continuous glucose monitoring device has been developed at Imperial College based on microprobe technology. It consists of a small, wearable patch (~1 cm2), the size of a conventional postage stamp, containing microscopic projections (microprobes) that penetrate only the outermost skin layer. It accesses interstitial fluid to sense its glucose content without stimulating skin nerve fibres or reaching blood vessels within skin layers. The microprobe surface has the consistency of sandpaper. It is pushed into the skin with an applicator allowing it to penetrate through the skin layers and access the interstitial fluid in a minimally invasive manner. The device is disposable and optimum performance will be assessed over five days. The advantages of microprobe technology have been demonstrated in other clinical situations and include painless insertion, absence of bleeding and a low infection risk. The large surface area utilised in our microprobe device has the potential to improve device sensitivity and accuracy. Pre-clinical validation tests have demonstrated the ability of the device to respond accurately to variable glucose concentrations and to penetrate the outermost skin layer without fracture. We aim now to further develop the device through clinical studies in non-diabetic subjects and subjects with type 1 diabetes to allow painless accurate continuous glucose monitoring.

The study will recruit 16 non-diabetic subjects and 20 subjects with type 1 diabetes.

It will be conducted over four phases;

oPhase 1 will assess safety, as a primary outcome, and efficacy, as a secondary outcome, in non-diabetic subjects over six hours in the clinical research facility where the device will be fitted and a cannula inserted for venous sampling every 15 minutes to measure venous blood glucose (YSI). Safety will be assessed with regards to skin inflammation and pain. Efficacy will be assessed in this phase by assessing magnitude of current measured by the microprobe array sensor and comparison of measured ISF glucose concentrations to simultaneous venous blood glucose samples (YSI).

oPhase 2 will also assess safety, as a primary outcome, and efficacy, as a secondary outcome, in non-diabetic subjects over a period of 24 hours. The first six hours in the clinical research facility (same as phase 1), then subject will be allowed to go home with the device to assess safety over that period.

oPhase 3 aims to assess efficacy of the device as a primary outcome and safety as a secondary outcome. This will be in subjects with type 1 diabetes over 24 hours as inpatients. Efficacy will be assessed mechanically (by the ability to penetrate the stratum corneum) and functionally (by the ability to accurately sense ISF glucose). The derived ISF glucose levels will be compared with simultaneous venous glucose samples (YSI) and with a commercially available CGM device (iPro2, Medtronic). Assessment of microprobe penetration of the stratum corneum will be performed using confocal microscopy, optical coherence tomography and in skin biopsies.

oPhase 4 aims to assess efficacy of the device as a primary outcome and safety as a secondary outcome. This will be in subjects with type 1 diabetes over 5 days in ambulatory situation. Efficacy will be assessed by comparing microprobe sensor derived ISF glucose levels against ISF glucose levels measured using a commercially available CGM device (iPro2, Medtronic). ;


Study Design


Related Conditions & MeSH terms


NCT number NCT01908530
Study type Interventional
Source Imperial College London
Contact
Status Completed
Phase N/A
Start date November 2013
Completion date June 2018

See also
  Status Clinical Trial Phase
Completed NCT03743779 - Mastering Diabetes Pilot Study
Completed NCT03786978 - Pharmaceutical Care in the Reduction of Readmission Rates in Diabetes Melitus N/A
Completed NCT01804803 - DIgital Assisted MONitoring for DiabeteS - I N/A
Completed NCT05039970 - A Real-World Study of a Mobile Device-based Serious Health Game on Session Attendance in the National Diabetes Prevention Program N/A
Completed NCT04507867 - Effect of a NSS to Reduce Complications in Patients With Covid-19 and Comorbidities in Stage III N/A
Completed NCT04068272 - Safety of Bosentan in Type II Diabetic Patients Phase 1
Completed NCT03243383 - Readmission Prevention Pilot Trial in Diabetes Patients N/A
Completed NCT03730480 - User Performance of the CONTOUR NEXT and CONTOUR TV3 Blood Glucose Monitoring System (BGMS) N/A
Recruiting NCT02690467 - Efficacy, Safety and Acceptability of the New Pen Needle 34gx3,5mm. N/A
Completed NCT02229383 - Phase III Study to Evaluate Safety and Efficacy of Added Exenatide Versus Placebo to Titrated Basal Insulin Glargine in Inadequately Controlled Patients With Type II Diabetes Mellitus Phase 3
Completed NCT05799976 - Text Message-Based Nudges Prior to Primary Care Visits to Increase Care Gap Closure N/A
Completed NCT06181721 - Evaluating Glucose Control Using a Next Generation Automated Insulin Delivery Algorithm in Patients With Type 1 and Type 2 Diabetes N/A
Recruiting NCT04489043 - Exercise, Prediabetes and Diabetes After Renal Transplantation. N/A
Withdrawn NCT03319784 - Analysis for NSAID VS Corticosteroid Shoulder Injection in Diabetic Patients Phase 4
Completed NCT03542084 - Endocrinology Auto-Triggered e-Consults N/A
Completed NCT02229396 - Phase 3 28-Week Study With 24-Week and 52-week Extension Phases to Evaluate Efficacy and Safety of Exenatide Once Weekly and Dapagliflozin Versus Exenatide and Dapagliflozin Matching Placebo Phase 3
Recruiting NCT05544266 - Rare and Atypical Diabetes Network
Completed NCT01892319 - An International Non-interventional Cohort Study to Evaluate the Safety of Treatment With Insulin Detemir in Pregnant Women With Diabetes Mellitus. Diabetes Pregnancy Registry
Completed NCT05031000 - Blood Glucose Monitoring Systems: Discounter Versus Brand N/A
Recruiting NCT04039763 - RT-CGM in Young Adults at Risk of DKA N/A