Clinical Trials Logo

Clinical Trial Details — Status: Not yet recruiting

Administrative data

NCT number NCT06305065
Other study ID # 2024.089
Secondary ID
Status Not yet recruiting
Phase N/A
First received
Last updated
Start date March 2024
Est. completion date May 2026

Study information

Verified date March 2024
Source Chinese University of Hong Kong
Contact Tim-yun Michael Ong
Phone 26364171
Email michael.ong@cuhk.edu.hk
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

REAL INTELLIGENCE™ CORI™ (CORI Surgical System) is a computer-assisted orthopedic surgical system. CORI Surgical System is designed to aid surgeons in planning and executing a procedure involving bone preparation for total knee arthroplasty (TKA) procedures. CORI Surgical System is comprised of a console control unit, optical tracking camera, primary and secondary input displays (tablet and optional display monitor), and foot pedal. The CORI Surgical System software consists of a patient and user management module, a surgical planner, and an intra-operative cutting module. Yuanhua Orthopaedic Robotic Systems, KUNWU, is an open-platform robotic system that does not restrict surgeons in choosing the type of prosthesis implant. It is the only Orthopaedic Robotic System in Hong Kong registered with the HK Department of Health Medical Devices Control Office (MDCO) as an open platform system. Unlike other manufacturer's implant-based robots (closed systems), Yuanhua's objective is to provide maximum flexibility in choosing the best implant for each patient. Closed system robots not only impact the surgeon's choice of implant for an individual patient but also affect the hospital's implant purchases over multiple years without any negotiation power on pricing. This business model is often referred to as a "razor and razor blade" model. The primary objective of this study is to evaluate the use of open and closed platform robotic-assisted TKA procedure in achieving post-operative leg alignment as compared to procedures using standard instruments. The secondary objective of this study is to assess the safety and performance of the robotic-assisted TKA procedure up to 12 months after surgery as compared to procedures using conventional manual instruments.


Recruitment information / eligibility

Status Not yet recruiting
Enrollment 90
Est. completion date May 2026
Est. primary completion date March 2026
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: 1. Subject is a suitable candidate for a robotic-assisted TKA procedure 2. Subject requires a cemented TKA as a primary indication that meets any of the following condition: - Degenerative joint disease, including osteoarthritis - Rheumatoid arthritis - Avascular necrosis - Requires correction of functional deformity - Requires treatment of fractures that were unmanageable using other techniques 3. Subject is of legal age to consent and considered skeletally mature (= 18 years of age at the time of surgery) 4. Subject agrees to consent to and to follow the study visit schedule (as defined in the study protocol and informed consent form), by signing the Ethical Committee (EC) or Institutional Review Board (IRB) approved informed consent form. 5. Subject plans to be available through two (2) year postoperative follow-up. 6. Applicable routine radiographic assessment is possible. Exclusion Criteria: 1. Subject requires a TKA on the index joint as a revision for a previously failed surgery, or has the need for complex implants, or any other implant than a standard TKA (e.g. stems, augments, or custom made devices). 2. Subject has been diagnosed with post-traumatic arthritis. 3. Subject requires bilateral TKA. 4. Subject does not understand the language used in the Informed Consent Form. 5. Subject does not meet the indication or is contraindicated for TKA according to the specific Smith+Nephew Knee System's Instructions For Use (IFU). 6. Subject has active infection or sepsis (treated or untreated). 7. Subject is morbidly obese with a body mass index (BMI) greater than 40. 8. Subject is pregnant or breast feeding at the time of surgery. 9. Subject, in the opinion of the Investigator, has advanced osteoarthritis or joint disease at the time of surgery and was better suited for an alternate procedure. 10. Subject has a condition(s) that may interfere with the TKA survival or outcome (i.e., Paget's or Charcot's disease, vascular insufficiency, muscular atrophy, uncontrolled diabetes, moderate to severe renal insufficiency or neuromuscular disease, or an active, local infection). 11. Subject in the opinion of the Investigator has an emotional or neurological condition that would pre-empt their ability or willingness to participate in the study including mental illness, intellectual disability, drug or alcohol abuse. 12. Subject, in the opinion of the Investigator, has a neuromuscular disorder that prohibited control of the index joint.

Study Design


Intervention

Procedure:
KUNWU Navigation TKA procedure
In terms of technical specifications, KUNWU is the only robotic arm with seven degrees of freedom, while other systems have a maximum of six. The ergonomic and user-friendly design of the system contributes to physical relief and simplified instrument handling, which enhances surgical precision and reduces cognitive stress. KUNWU's navigation system boasts a refresh rate of 335Hz, which is significantly higher than the current 60Hz rate of other navigation systems. This high refresh rate provides a clear and visually captivating display of the navigation procedure, eliminating blurriness and indecipherable output. It enables surgeons to react promptly during live procedures, enhancing safety for both clinicians and patients and reducing potential complications and hospitalization.
CORI Surgical System TKA procedure
The CORI Surgical System (Smith and Nephew®) represents one of such recent advances in robotics that it can assist surgical planning, and increase the accuracy of implant position due to real-time feedback during the procedure (bone resection, implant position, ligamentous balance).
Conventional TKA procedure
Total knee arthroplasty (TKA) is a highly successful and frequently performed surgical treatment to reduce disability caused by end-stage osteoarthritis and other conditions affecting articular cartilage. Technical outcomes for TKA are excellent, with favorable postoperative health-related quality of life. Also, survivorship of primary knee replacements is excellent with reported survivorship of 82.3% at 25 years. TKA has traditionally been indicated in the elderly population with relatively sedentary lifestyles, but more active, younger patients (<55) are receiving TKA due to the desire for a pain-free, active lifestyle with the demand projected to continue to increase for this group. A recent systematic review has shown that functional outcomes are similar in this population compared to elderly patients with no increase in the burden of revision.

Locations

Country Name City State
Hong Kong The Chinese University of Hong Kong Hong Kong

Sponsors (1)

Lead Sponsor Collaborator
Chinese University of Hong Kong

Country where clinical trial is conducted

Hong Kong, 

Outcome

Type Measure Description Time frame Safety issue
Primary Post-operative leg alignment - Hip-knee-ankle axis (HKA axis) The primary objective of this study is to evaluate the use of open and closed platform robot in TKA procedure in achieving post-operative leg alignment as compared to procedures using conventional manual instruments.
The mechanical axis of the lower limb is calculated as the angle between the following two lines: the first line drawn from the centre of the femoral head to the centre of the knee joint, and the second line is drawn from the centre of the knee to the centre of the ankle joint.
Record the correct angle in degrees for 'Leg Alignment on Standing long leg X-Ray - Provide angle and select one position Angle (neutral/ varus/ valgus)'. The angular deviation will be measured from the neutral position (180°).
pre-operative visit, day of surgery, 6 weeks, 6 months, and 12 months after surgery
Secondary Lateral View Femoral Flexion Angle: The lateral view femoral flexion angle (X) is obtained from the intersection of a line from the center of the femoral implant to the top of the femur with a line through the femoral canal. The angle is measured on the proximal side of the intersection Tibial Lateral Angle: The lateral view tibial angle (Y) is the angle obtained from the intersection of a line drawn parallel to the bottom of the tibial base insert and a line through the center of the tibial base and the tibial canal. pre-operative visit, day of surgery, 6 weeks, 6 months, and 12 months after surgery
Secondary Standard Radiographic Evaluation - Femoral coronal alignment (FCA) The femoral prosthesis coronal alignment is the degree to which the femoral prosthesis is deviated from the mechanical axis of the lower extremity. pre-operative visit, day of surgery, 6 weeks, 6 months, and 12 months after surgery
Secondary Standard Radiographic Evaluation - Femoral sagittal alignment (FSA) The femoral sagittal alignment gives the flexion of the femoral component in lateral view. The flexion of the component is the angle formed between the mechanical axis of the femur in the sagittal plane and the line perpendicular to the tangent of the distal portion of the femoral component. pre-operative visit, day of surgery, 6 weeks, 6 months, and 12 months after surgery
Secondary Standard Radiographic Evaluation - Femoral component rotation (FCR) The rotation of the femoral component is defined on the axial section of the post-operative CT scan. The angle of deviation between the radiographic trans-epicondylar axis (rTEA) and femoral prosthesis posterior condylar line (FPPCL) is the amount of femoral component rotation. pre-operative visit, day of surgery, 6 weeks, 6 months, and 12 months after surgery
Secondary Standard Radiographic Evaluation - Tibial coronal alignment (TCA) The tibial prosthesis coronal alignment gives the varus/valgus angulation of the prosthesis which affects the mechanical axis of the lower limb. pre-operative visit, day of surgery, 6 weeks, 6 months, and 12 months after surgery
Secondary Standard Radiographic Evaluation - Tibial slope The tibial slope is calculated pre-operatively as the angle between the perpendicular to the anatomical axis of the tibia and the line joining the anterior and posterior point of the tibial surface on the lateral view. pre-operative visit, day of surgery, 6 weeks, 6 months, and 12 months after surgery
Secondary Standard Radiographic Evaluation - Joint line distance In this study, the tip of the fibular head is used as the fixed bony point to calculate the joint line pre- and post-operatively. Pre-operatively, the perpendicular distance from the tip of the fibular head to the joint line of knee was termed as the joint line distance. Post-operatively, the perpendicular distance from the tip of the fibular head to the line joining the medial and lateral femoral prosthesis was termed as the joint line distance. pre-operative visit, day of surgery, 6 weeks, 6 months, and 12 months after surgery
Secondary Knee Society Score (KSS) The KSS is a validated tool that combines an objective physician-derived component with a subjective subject-derived component. The KSS consists of 34 questions and provides sub-scores across 4 dimensions, including Objective Knee Score, Symptoms, Subject Satisfaction Score, Subject Expectation, and Functional Knee Score.
The Objective Knee Score is rated by the clinician and assesses a range of clinical outcomes: TKA alignment, stability, range of motion (ROM) and symptoms.
The KSS is an instrument assessing patient's pain and functionality based on a series of questions interviewed by a clinician. The validated questionnaire combines the objective physician derived component with a subjective patient derived component which evaluates pain, functionality, satisfaction and fulfillment of expectations. The results will be calculating the total score with 100 being the highest and 0 the lowest.
pre-operative visit, day of surgery, 6 weeks, 6 months, and 12 months after surgery
Secondary Oxford Knee Score (OKS) The OKS will be collected at the pre-operative visit and 6 weeks, 6 months, and 12 months after surgery.
The OKS is a Patient Reported Outcome (PRO) questionnaire that was developed to specifically assess the patient's perspective of outcome following Total Knee Arthroplasty. The OKS is a patient self-completion PRO containing 12 equally weighted questions on activities of daily living. The OKS has been developed and validated specifically to assess perceived function and pain answered on a Likert scale after TKA. Responses to each question ranges from 0-4 with a range of a possible overall score from 0-48. A score of 0 is the worst possible outcome while a score of 48 is the best possible outcome. The benefit to this questionnaire is that it is short, practical, reliable, valid and sensitive to clinically important changes over time.
A paper questionnaire will be provided by the Sponsor to be completed by the subject. Responses for the OKS will then be recorded.
pre-operative visit, day of surgery, 6 weeks, 6 months, and 12 months after surgery
Secondary HEALTH ECONOMICS/QUALITY OF LIFE - EQ-5D-5L The EQ-5D-5L essentially consists of 2 pages: the EQ-5D descriptive system and the EQ visual analogue scale (EQ VAS).
The descriptive system is used to describe the subject's health state and consists of five dimensions: mobility, self-care, usual activities, pain/discomfort, and anxiety/depression. Each dimension has 5 levels to choose the most appropriate answer: no problems, slight problems, moderate problems, severe problems, and extreme problems. The subject is asked to indicate his/her health state by marking the most appropriate statement in each of the five areas.
Each dimension in the EQ-5D-5L has five response levels: no problems (Level 1); slight; moderate; severe; and extreme problems (Level 5). There are 3,125 possible health states defined by combining one level from each dimension, ranging from 11111 (full health) to 55555 (worst health)
pre-operative visit, day of surgery, 6 weeks, 6 months, and 12 months after surgery
Secondary Forgotten Joint Score (FJS) The FJS will be collected at 6 weeks, 6 months, and 12 months after surgery. A paper questionnaire will be provided to be completed by the subject.
The FJS comprises measures for the assessment of joint-specific patient reported outcomes. This questionnaire focuses on the study subject's awareness of the partially or fully replaced knee joint in everyday life. Joint awareness can be simply defined as any unintended perception of a joint. Subjects are asked to rate their awareness of their knee arthroplasty in 12 questions with a five point Likert response format: "Never", "almost never", "seldom", "sometimes" and "mostly". The item scores are summed and linearly transformed in a 0 to 100 scale with a high value reflecting the ability of the subject to forget about the replaced knee joint during the activities of daily living.
A paper questionnaire will be provided to be completed by the subject. Responses for the FJS will then be recorded.
pre-operative visit, day of surgery, 6 weeks, 6 months, and 12 months after surgery
See also
  Status Clinical Trial Phase
Recruiting NCT04651673 - Prescribed Knee Brace Treatments for Osteoarthritis of the Knee (Knee OA)
Completed NCT05677399 - Knee Osteoarthritis Treatment With Peloidotherapy and Aquatic Exercise. N/A
Active, not recruiting NCT04043819 - Evaluation of Safety and Exploratory Efficacy of an Autologous Adipose-derived Cell Therapy Product for Treatment of Single Knee Osteoarthritis Phase 1
Recruiting NCT06000410 - A Study to Evaluate the Efficacy of Amniotic Suspension Allograft in Patients With Osteoarthritis of the Knee Phase 3
Completed NCT05014542 - Needling Techniques for Knee Osteoarthritis N/A
Recruiting NCT05892133 - Prehabilitation Effect on Function and Patient Satisfaction Following Total Knee Arthroplasty N/A
Recruiting NCT05528965 - Parallel Versus Perpendicular Technique for Genicular Radiofrequency N/A
Active, not recruiting NCT03472300 - Prevalence of Self-disclosed Knee Trouble and Use of Treatments Among Elderly Individuals
Active, not recruiting NCT02003976 - A Randomized Trial Comparing High Tibial Osteotomy Plus Non-Surgical Treatment and Non-Surgical Treatment Alone N/A
Active, not recruiting NCT04017533 - Stability of Uncemented Medially Stabilized TKA N/A
Completed NCT04779164 - The Relation Between Abdominal Obesity, Type 2 Diabetes Mellitus and Knee Osteoarthritis N/A
Recruiting NCT04006314 - Platelet Rich Plasma and Neural Prolotherapy Injections in Treating Knee Osteoarthritis N/A
Recruiting NCT05423587 - Genicular Artery Embolisation for Knee Osteoarthritis II N/A
Enrolling by invitation NCT04145401 - Post Market Clinical Follow-Up Study- EVOLUTION® Revision CCK
Active, not recruiting NCT03781843 - Effects of Genicular Nerve Block in Knee Osteoarthritis N/A
Recruiting NCT05974501 - Pre vs Post Block in Total Knee Arthroplasty (TKA) Phase 4
Completed NCT05324163 - Evaluate Efficacy and Safety of X0002 in Treatment of Knee Osteoarthritis Phase 3
Completed NCT05529914 - Effects of Myofascial Release and Neuromuscular Training for Pes Anserine Syndrome Associated With Knee Osteoarthritis N/A
Recruiting NCT05693493 - Can Proprioceptive Knee Brace Improve Functional Outcome Following TKA? N/A
Not yet recruiting NCT05510648 - Evaluation of the Effect of High-intensity Laser Therapy in Knee Osteoarthritis N/A