Clinical Trials Logo

Clinical Trial Summary

The purpose of our study is to determine if anatomic/kinematic total knee arthroplasties (TKAs) are superior to mechanical axis-referenced TKAs with respect to determinants of gait functionality, patient satisfaction and other objective tests of knee function as a potential indicator of long-term prosthesis outcomes. To our knowledge there has not been any literature comparing TKAs using the kinematic and mechanical axes with respect to gait analysis. A single study has compared gender-specific TKAs and found that there is no difference with respect to determinants of gait when using these prostheses (Thomsen et al, 2012), but again this study was not based on referencing off of the anatomical/kinematic axis of the knee. Our group is hoping that the small variability that may be detectable with the precision of gait analysis may be used as a predictor of future prosthesis outcome measures.


Clinical Trial Description

The reference standard for total knee replacement or total knee arthroplasty (TKA) has historically been based on a 2-dimensional "mechanical axis" of the knee which surgically creates a joint line parallel to the ground. This is based on the idea that this alignment will evenly distribute the stress on the prosthesis, thus improving the wear characteristics and longevity of the replacement. More recent studies have shown that TKAs with greater than 3 degree deviation (in either valgus or varus) from this previously accepted ideal does not convey a survival benefit over a 15 year period. This is not to say that alignment does not play a role in survivorship as gross deviation from neutral does result in earlier implant failure, but a simple 2-D model may not be the ideal approach to TKAs. With the developments and improvements in patient-specific technology (or patient-specific instrumentation (PSI)), our ability to create TKAs that reproduce the patient's original anatomic or kinematic alignment in 3-Dimensions has dramatically improved. Early research with respect to function and survivorship has shown that PSIs are at least equivalent when compared to conventional TKAs. Some studies have also suggested improvements with respect to shorter operating times, less blood loss and increased range of motion. Most of the current PSI TKA literature has placed an emphasis on the technology's effect on TKA alignment or to show that it is bioequivalent with respect to range of motion or early prosthesis survivorship when compared to conventional TKAs. Although a single study using PSIs (Howell et al., 2013) has shown improvement in Oxford Knee Scores when comparing patients preoperatively to postoperatively, to our knowledge there is no research done to directly compare the functional knee scores between a mechanically-aligned and anatomically aligned TKA. This randomized control trial will compare these two approaches using implants from the same manufacturer and also hope to identify more subtle functional differences using power testing and gait analysis, in addition to assessing other perioperative outcomes such as blood loss, hospital stay duration and operative time. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03117959
Study type Interventional
Source Queen's University
Contact
Status Withdrawn
Phase N/A
Start date February 2014
Completion date February 2015

See also
  Status Clinical Trial Phase
Recruiting NCT04651673 - Prescribed Knee Brace Treatments for Osteoarthritis of the Knee (Knee OA)
Completed NCT05677399 - Knee Osteoarthritis Treatment With Peloidotherapy and Aquatic Exercise. N/A
Active, not recruiting NCT04043819 - Evaluation of Safety and Exploratory Efficacy of an Autologous Adipose-derived Cell Therapy Product for Treatment of Single Knee Osteoarthritis Phase 1
Recruiting NCT06000410 - A Study to Evaluate the Efficacy of Amniotic Suspension Allograft in Patients With Osteoarthritis of the Knee Phase 3
Completed NCT05014542 - Needling Techniques for Knee Osteoarthritis N/A
Recruiting NCT05892133 - Prehabilitation Effect on Function and Patient Satisfaction Following Total Knee Arthroplasty N/A
Recruiting NCT05528965 - Parallel Versus Perpendicular Technique for Genicular Radiofrequency N/A
Active, not recruiting NCT03472300 - Prevalence of Self-disclosed Knee Trouble and Use of Treatments Among Elderly Individuals
Active, not recruiting NCT02003976 - A Randomized Trial Comparing High Tibial Osteotomy Plus Non-Surgical Treatment and Non-Surgical Treatment Alone N/A
Active, not recruiting NCT04017533 - Stability of Uncemented Medially Stabilized TKA N/A
Completed NCT04779164 - The Relation Between Abdominal Obesity, Type 2 Diabetes Mellitus and Knee Osteoarthritis N/A
Recruiting NCT04006314 - Platelet Rich Plasma and Neural Prolotherapy Injections in Treating Knee Osteoarthritis N/A
Recruiting NCT05423587 - Genicular Artery Embolisation for Knee Osteoarthritis II N/A
Enrolling by invitation NCT04145401 - Post Market Clinical Follow-Up Study- EVOLUTION® Revision CCK
Active, not recruiting NCT03781843 - Effects of Genicular Nerve Block in Knee Osteoarthritis N/A
Recruiting NCT05974501 - Pre vs Post Block in Total Knee Arthroplasty (TKA) Phase 4
Completed NCT05324163 - Evaluate Efficacy and Safety of X0002 in Treatment of Knee Osteoarthritis Phase 3
Completed NCT05529914 - Effects of Myofascial Release and Neuromuscular Training for Pes Anserine Syndrome Associated With Knee Osteoarthritis N/A
Recruiting NCT05693493 - Can Proprioceptive Knee Brace Improve Functional Outcome Following TKA? N/A
Not yet recruiting NCT05510648 - Evaluation of the Effect of High-intensity Laser Therapy in Knee Osteoarthritis N/A