Clinical Trial Summary

Cardiac Resynchronization Therapy (CRT) is a proven treatment for heart failure. CRT consists of a special pacemaker with two/three leads (insulated wires which take the electrical impulses from the device to the heart), one in the right ventricle, one in a vein on the outer surface of the left ventricle (in a vessel called coronary sinus or CS) and sometimes one in the right atrium (right top chamber of the heart). Tiny electrical impulses are simultaneously sent to the ventricles to make them beating together again in a more synchronised pattern. This leads to a coordinated, synchronous pumping action that, in most patients, translates into improved heart failure symptoms and improved quality and quantity of life, reducing the chance of being admitted to hospital with worsening heart failure. Unfortunately up to one third of the patients do not benefit from CRT therapy and to date there are no useful criteria to predict the response to CRT. In an effort to improve the response rate to CRT, alternative methods have been developed. In particular, a new technology called MultiPoint Pacing (MPP) (St. Jude Medical, Sylmar, CA) has recently become available. It allows simultaneous stimulation of 2 different points in the left ventricle by using a single lead with four electrodes. This strategy should improve the pumping function of the heart by recruiting a larger mass of muscle. Although MPP is as safe and as effective as standard CRT pacing, the improvements to date in the heart pump function it gives over standard CRT pacing are variable and small. Recent evidence suggests that MPP pacing could be particularly beneficial in some subgroups of patients, in particular patients with a previous history of heart attack resulting in scar formation in the left ventricle. The investigators hypothesize that MPP works better when the lead is closer to the scar because this allows recruitment of areas with slow conduction, thus increasing synchronization further. To this aim, they plan to compare, in each patient, the acute response produced by MPP on the cardiac function when the CS lead is placed close to myocardial scar and when it is placed far from scar respectively.


Clinical Trial Description

A prospective single-centre pilot study will be conducted to investigate this topic. Fifteen patients, with a history of previous ST Elevation Myocardial Infarction (STEMI) resulting in myocardial scar and elected to CRT implant at the OUH, will be enrolled in this study. Compared to standard practice, additional research investigations will be a baseline visit for eligibility assessment, informed consent and pre-CRT implant cardiac MRI, a three-dimensional electroanatomical map reconstruction of the CS venous system during the standard CRT implant and the evaluation of the acute haemodynamic response (AHR, percentage increase of LV-dP/dT max) of MPP over conventional single-site LV pacing during the CRT implant. The cardiac Magnetic Resonance Imaging (MRI) will be performed in each patient 1-2 weeks before the CRT implant during the baseline visit. It will provide information regarding presence and location of myocardial scar and anatomy of the CS venous system. A de-novo CRT implant will be performed under fluoroscopic guidance as per standard care. All subjects will be implanted with a regulatory approved St. Jude Medical CRT device compatible with MPP feature (models n° CD3271-40(Q), CD3371-40(Q), CD3371-40C(QC) or newer) and St. Jude Medical quadripolar left ventricular lead (Quartet 1458Q or newer). The choice of the right ventricular and right atrial leads will be left to the operator. After implant of the right ventricular and right atrial leads, a CS venogram will be then performed as per standard practice (see intervention section for more details). A three-dimensional electroanatomical map of the CS venous system will be constructed with Precision mapping system and a Biotronik Vision wire (Biotronik Se & Co. KG, Berlin, Germany) by using the CS venogram as a guide. The map will be merged with the correspondent cardiac MRI images in order to locate the myocardial scar in respect to the CS branches. This will allow the identification of two target CS branches for the study measurements, one located in the peri-infarct region and one located in the remote myocardium. A Certus PressureWire will be then introduced into the LV. A PhysioMon software (Radi Medical Systems, Uppsala, Sweden) will be used for electronic calculation of the LV-dP/dTmax from every heartbeat for a period of at least thirty seconds to ensure steady-state conditions. The baseline LV-dP/dTmax will be measured during ventricular spontaneous rhythm. A St. Jude Medical quadripolar left ventricular lead will be sequentially placed in the "peri-infarct" CS branch and in the "remote myocardium" CS branch. In each site the percentage increase in LV-dP/dTmax (Acute Haemodynamic Response, AHR) produced by both conventional single-site and MPP LV pacing to will be measured. All 4 poles of the quadripolar lead will be used in turn for conventional single-site LV pacing, 3 different configurations will be used in turn for MPP. The LV-dP/dTmax will be recorded for each pacing configuration in order to identify the MPP and the single-site LV pacing configurations producing the best AHR (best percentage increase of LV-dP/dTmax). The AHR produced by the best MPP configuration in peri-infarct region will be compared with the AHR produced by the best MPP configuration in the remote myocardium. Moreover, the percentage increase of LV-dP/dTmax produced by the best MPP configuration over the best conventional single-site LV pacing in the peri-infarct region will be compared with the same measurement obtained in the remote myocardium. The decision about the final position of the LV lead and the activation of MPP feature after the CRT implant will be left to operator preference. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04066738
Study type Interventional
Source Oxford University Hospitals NHS Trust
Contact
Status Terminated
Phase N/A
Start date September 27, 2017
Completion date March 30, 2020

See also
  Status Clinical Trial Phase
Recruiting NCT05654272 - Development of CIRC Technologies
Recruiting NCT05650307 - CV Imaging of Metabolic Interventions
Recruiting NCT05196659 - Collaborative Quality Improvement (C-QIP) Study N/A
Active, not recruiting NCT05896904 - Clinical Comparison of Patients With Transthyretin Cardiac Amyloidosis and Patients With Heart Failure With Reduced Ejection Fraction N/A
Completed NCT05077293 - Building Electronic Tools To Enhance and Reinforce Cardiovascular Recommendations - Heart Failure
Recruiting NCT05631275 - The Role of Bioimpedance Analysis in Patients With Chronic Heart Failure and Systolic Ventricular Dysfunction
Enrolling by invitation NCT05564572 - Randomized Implementation of Routine Patient-Reported Health Status Assessment Among Heart Failure Patients in Stanford Cardiology N/A
Enrolling by invitation NCT05009706 - Self-care in Older Frail Persons With Heart Failure Intervention N/A
Recruiting NCT04177199 - What is the Workload Burden Associated With Using the Triage HF+ Care Pathway?
Terminated NCT03615469 - Building Strength Through Rehabilitation for Heart Failure Patients (BISTRO-STUDY) N/A
Recruiting NCT06340048 - Epicardial Injection of hiPSC-CMs to Treat Severe Chronic Ischemic Heart Failure Phase 1/Phase 2
Recruiting NCT05679713 - Next-generation, Integrative, and Personalized Risk Assessment to Prevent Recurrent Heart Failure Events: the ORACLE Study
Completed NCT04254328 - The Effectiveness of Nintendo Wii Fit and Inspiratory Muscle Training in Older Patients With Heart Failure N/A
Completed NCT03549169 - Decision Making for the Management the Symptoms in Adults of Heart Failure N/A
Recruiting NCT05572814 - Transform: Teaching, Technology, and Teams N/A
Enrolling by invitation NCT05538611 - Effect Evaluation of Chain Quality Control Management on Patients With Heart Failure
Recruiting NCT04262830 - Cancer Therapy Effects on the Heart
Completed NCT06026683 - Conduction System Stimulation to Avoid Left Ventricle Dysfunction N/A
Withdrawn NCT03091998 - Subcu Administration of CD-NP in Heart Failure Patients With Left Ventricular Assist Device Support Phase 1
Recruiting NCT05564689 - Absolute Coronary Flow in Patients With Heart Failure With Reduced Ejection Fraction and Left Bundle Branch Block With Cardiac Resynchronization Therapy