Coronary Artery Disease Clinical Trial
Official title:
Safety and Efficacy of the GUIDEX® Versus Launcher™ Guiding Catheter in Adults' Patients With Coronary Artery Disease (CAD) Requiring Percutaneous Coronary Intervention (PCI): a Non-inferiority and Randomized, Clinical Trial.
The goal of this clinical trial is to compare two guiding catheters in patients with coronary artery disease during a percutaneous coronary intervention between Guidex® Guiding catheter (DEMAX) and Launcher™ coronary guide catheters (Medtronic). The main question[s] it aims to answer are: - Aren't the safety of medical devices inferior to each other? - Aren't the efficacyof medical devices inferior to each other? Participants will be randomized (1:1) and have a percutaneous coronary interventionwith one of the two guiding catheters.
Cardiovascular disease (CVD) remains the most common cause of death in the European region. In line with the Global Burden of Disease (GBD) estimates from 2001, 43% of all Cardio Vascular Disease (CVD) deaths are related to coronary artery disease (CAD). Treatment of CAD is always based on medication, which may also be supplemented by invasive procedures. The most significant historical advances in the treatment of coronary artery disease were the development of coronary artery bypass grafting (CABG) and percutaneous coronary intervention (PCI). An essential element in the success of an angioplasty and in shortening the procedure, the guiding catheter is not simply a support. While, it's primary role is designed to provide a pathway through which balloon dilation catheter, guide wire or other devices are introduced, it can also contribute to significant semantic information since it is the first tool to appear in the field of view. A variety of guiding catheter references are available on the market. Guiding catheters of various sizes and shapes are selected based on vessel anatomy, lesion characteristics, vascular access and procedural complexity. The GUIDEX® device is a guiding catheter designed to be used in percutaneous coronary intervention. GUIDEX® device is on the Chinese market since September 2015 (certificate renewal in 2020) and is presented for CE marking according to MDR 2017/745. The aim of the study is to assess the essential requirements for CE marking of Guidex®: the efficacy and safety of the device. Thus the aim of this non-inferiority study is to compare the efficacy and safety for patients with coronary artery disease during a percutaneous coronary intervention between Guidex® Guiding catheter (DEMAX) and Launcher™ coronary guide catheters (Medtronic). ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT06030596 -
SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
|
||
Completed |
NCT04080700 -
Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
|
||
Recruiting |
NCT03810599 -
Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study
|
N/A | |
Recruiting |
NCT06002932 -
Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions.
|
N/A | |
Not yet recruiting |
NCT06032572 -
Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE)
|
N/A | |
Recruiting |
NCT05308719 -
Nasal Oxygen Therapy After Cardiac Surgery
|
N/A | |
Recruiting |
NCT04242134 -
Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions
|
N/A | |
Completed |
NCT04556994 -
Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients.
|
N/A | |
Recruiting |
NCT05846893 -
Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease
|
N/A | |
Recruiting |
NCT06027788 -
CTSN Embolic Protection Trial
|
N/A | |
Recruiting |
NCT05023629 -
STunning After Balloon Occlusion
|
N/A | |
Completed |
NCT04941560 -
Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
|
||
Completed |
NCT04006288 -
Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease
|
Phase 4 | |
Completed |
NCT01860274 -
Meshed Vein Graft Patency Trial - VEST
|
N/A | |
Recruiting |
NCT06174090 -
The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients
|
N/A | |
Terminated |
NCT03959072 -
Cardiac Cath Lab Staff Radiation Exposure
|
||
Completed |
NCT03968809 -
Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
|
||
Recruiting |
NCT05065073 -
Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography
|
Phase 4 | |
Recruiting |
NCT04566497 -
Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up.
|
N/A | |
Completed |
NCT05096442 -
Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions
|
N/A |