Clinical Trials Logo

Clinical Trial Summary

The novolimus-eluting DynamX bioadaptor system is composed of 71 µm cobalt-chromium sinusoidal rings connected to each other axially by three S-links Each ring contains three uncaging elements that are positioned at equal distance in low stress regions of struts oriented in a helical configuration along the length of the bioadaptor which remain intact after uncaging. The uncaging elements consist of three separable junctions per ring held together by a 6 µm polymer coating that is resorbed over six months, allowing uncaging of the vessel and adaptive remodeling. Previous study showed the DynamX biodaptor is safe and effective treating in de novo coronary lesion. It also increased of vessel and device area while maintain in the mean lumen area after one year follow-up. However, the unchanging effect of Dynamx bioadaptor on coronary geometry change remained unknown. The present randomized control study is designed to investigate the differences of dynamic coronary artery geometry changes evaluated by coronary computed tomography angiography after DynamX Bioadaptor and permanent metallic DES implantation.


Clinical Trial Description

Coronary artery disease (CAD) is the most common type of heart disease and the leading cause of death worldwide. Percutaneous coronary intervention and coronary artery bypass graft are the guideline suggested treatment. Drug-eluting stents (DES) is the guideline suggested treatment options. Percutaneous coronary intervention with DES provides not just acute luminal gains, but also good long-term patency and clinical outcomes. However, in-stent neoatherosclerosis, very late stent thrombosis, and endothelial dysfunction remained important long-term issues. In addition, metallic stent encages the vessel segment, limits its remodeling and vasomotor function. The original vessel geometry, curvature, tortuosity, and wall shear stress, which are associated with plaque formation are also changed permanently by stent implantation. Although bioresorbable scaffolds attempted to address these issues by providing structural support to the vessel early on, followed by resorption, randomized trials showed that, prior to their resorption, they were less safe and effective than contemporary DES. Since that, the novel DES, DynamX Bioadaptor, is designed to improve these limitations. The novel DES, DynamX Bioadaptor, is designed to restore normal pulsatility and adaptive remodeling in blood vessels after stent implantation. It is a cobalt-chromium stent with a biodegradable polymer coating that releases novolimus. Segments of the stent are held together by the polymer coating, which is designed to be fully absorbed in 6 months. After degradation of polymer, the stent struts unlink and uncage the stented segment. Pilot study demonstrated vessel uncaging and restoration of cyclic pulsatility 12 months after DynamX Bioadaptor implantation. Adaptive remodeling 12 months after DynamX Bioadaptor implantation will restore flexibility and natural geometry of the stented vessel segment. Thus, the dynamic beat-to-beat (cardiac cycle) changes of curvature and tortuosity will be more pronounced in the DynamX Bioadaptor group compared with that in the permanent metallic Elixir DESyne DES group. The DynamX Bioadaptor can potentially restore the vessel geometry and improve outcomes. The present randomized control study is designed to investigate the differences of dynamic coronary artery geometry changes after DynamX Bioadaptor and permanent metallic DES implantation, using coronary computed tomography angiography (CCTA) as an evaluation tool. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04936191
Study type Interventional
Source National Taiwan University Hospital
Contact Hsien-Li Kao, MD
Phone +886-2-23123456
Email hsienli_kao@yahoo.com
Status Not yet recruiting
Phase N/A
Start date September 2022
Completion date December 2023

See also
  Status Clinical Trial Phase
Recruiting NCT06030596 - SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
Completed NCT04080700 - Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
Recruiting NCT03810599 - Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study N/A
Recruiting NCT06002932 - Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions. N/A
Not yet recruiting NCT06032572 - Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE) N/A
Recruiting NCT05308719 - Nasal Oxygen Therapy After Cardiac Surgery N/A
Recruiting NCT04242134 - Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions N/A
Completed NCT04556994 - Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients. N/A
Recruiting NCT05846893 - Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease N/A
Recruiting NCT06027788 - CTSN Embolic Protection Trial N/A
Recruiting NCT05023629 - STunning After Balloon Occlusion N/A
Completed NCT04941560 - Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
Completed NCT04006288 - Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease Phase 4
Completed NCT01860274 - Meshed Vein Graft Patency Trial - VEST N/A
Recruiting NCT06174090 - The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients N/A
Terminated NCT03959072 - Cardiac Cath Lab Staff Radiation Exposure
Completed NCT03968809 - Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
Recruiting NCT04566497 - Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up. N/A
Recruiting NCT05065073 - Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography Phase 4
Completed NCT05096442 - Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions N/A