Clinical Trials Logo

Clinical Trial Details — Status: Not yet recruiting

Administrative data

NCT number NCT03375528
Other study ID # DankookMMP
Secondary ID
Status Not yet recruiting
Phase N/A
First received November 20, 2017
Last updated December 14, 2017
Start date January 1, 2018
Est. completion date May 1, 2019

Study information

Verified date December 2017
Source Dankook University
Contact Tae Soo Kang, PhD
Phone 821093599160
Email neosoo70@dankook.ac.kr
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

If intimal growth is such that the initial lumen is narrowed significantly, distal blood flow is restricted and chronic tissue ischemia results. This occurs in native coronary arteries and during restenosis after coronary angioplasty or failure of some coronary vein grafts. Stent implantation has become the principal revascularization technique for coronary artery disease. But, in-stent restenosis (ISR) by neointimal hyperplasia persists as a significant limitation of this procedure in the era of drug eluting stent (DES). Coronary intervention might induce an inflammatory response by arterial wall damage, release of inflammatory and chemoattractant factors resulting in leukocyte and platelet activation. Then, Migration and proliferation of neointimal smooth muscle cells together with the deposition of extracellular matrix might lead to the development of ISR.

It is known that matrix metalloproteinases (MMPs) play a key role in the pathogenesis of restenosis by controlling extracellular matrix degradation and the release of matrix-degrading MMPs, including MMP -2 and MMP-9, which facilitate intimal remodeling after angioplasty. Previous studies showed that increased levels of MMPs in coronary arteries undergoing percutaneous intervention may be associated with vascular remodeling and restenosis by promoting migration of vascular smooth muscle cells. Recently, Gregory et al. demonstrated that elevated serum activities of MMP-2 and -9 are associated with dramatically increased restenosis rates after PCI with implantation of DES.

In patients with DESs, determination of MMP levels might be useful for identification of patients who are at high risk for ISR. However, not much is known about the relationship between MMPs and neointimal hyperplasia in patients with DES. In this study, the serum activity of MMP-2 and 9 were investigated in patients who had undergone follow-up coronary angiography with intravascular ultrasound (IVUS), which performed at 9 months post-DES implantation. Our aim was to evaluate if individual or combined levels of MMPs were associated with increased neointimal hyperplasia volume, that is, to evaluate the relationship, correlation between the levels of MMPs and neointimal hyperplasia volume.


Description:

Materials and methods Subjects (patients) Patients derived from a population of patients referred to 12 months follow-up coronary angiography for ischemic heart disease who are enable to be performed IVUS will be enrolled in the present trial, between Dec 2017 and Dec 2018. The study was an all comers design involving consecutive enrollment of patients with stable angina or acute coronary syndrome who had at least 1 coronary lesion (defined as a stenosis of >50%) suitable for stent implantation 9 months before. The follow-up coronary angiography was performed according to standard techniques by experienced interventionalists only. In-stent restenosis was defined as a diameter stenosis ≥50% of the vessel reference diameter by visual assessment at the site of the lesion treated with the stent observed in ≥1 multiple projections. The single most severe view was used to categorize the pattern of restenosis as proposed by Mehran et al for classification of in-stent restenotic lesions. Detailed demographic details including anthropometric measurements, cardiovascular risk factors and medication use were recorded for the participants.

Angiographic analysis (QCA-analysis) The off-line quantitative coronary angiographic analysis was performed with an automated edge-detection system (QCA-CMS Version 6.0, Medis, Medical Imaging Systems, Leiden, the Netherlands). The contrast-filled, non-tapered catheter tip was used for calibration. The reference diameter was measured by interpolation. Minimal lumen diameter (before and after PCI) and diameter stenosis (before and after PCI) were measured within the stent and within the 5-mm proximal and distal edges of the stent. Furthermore, we measured vessel size, lesion length, and length of stented segment. All analyses were performed by the same investigator that was blinded to all laboratory results.

IVUS imaging and analysis IVUS imaging was performed after intracoronary administration of 0.2 mg nitroglycerin, using a motorized transducer pullback (0.5 mm/s) and a commercial scanner (Boston Scientific/SCIMED, Minneapolis, MN) consisting of a rotating 40-MHz transducer within a 3.2 Fr imaging sheath. The decision to perform IVUS was at the operator's discretion. All IVUS data were assessed off-line by experienced professionals unaware of the allocated stent type or clinical information. Using computerized planimetry (EchoPlaque 2.7, Indec Systems, Mountain View, CA), stent and reference segments were assessed every 1 mm. In-stent measurements were obtained every 1 mm and included EEM, stent, intra-stent lumen, peristent plaque+media (EEM minus stent), and IH (stent minus intra-stent lumen) areas and volumes. Percent IH was defined as IH divided by stent. All volumes were calculated using the Simpson rule and then normalized by stent length (normalized volume).

Blood samples Blood samples were taken under fasting conditions directly before follow-up angiography. Arterial blood was drawn from the coronary arteries into serum separator tubes and samples serums were allowed to clot for 30 min before centrifugation at 1,000 g for 10 minutes and stored at -70°C until use.

Laboratory measurement Endogenous MMP-2 and MMP-9 were measured in serum using a standardized enzyme-linked immunosorbent assay (ELISA; R&D systems). This system measures the endogenous activity of the specific MMPs.

Sample size estimations:

Sample size calculation was based on the null hypothesis that MMP-2 and/or -9 activity showed no correlation with neointimal hyperplasia volume. Using the Lachin formula, sample size calculations were performed to show the expected correlation coefficient (r) more than 0.40 between both group, two-sided alpha 0.05 and 80% statistical power. Finally, 47 patients were calculated.

Statistical analysis :

Continuous variables are expressed as mean±SD. Categorical variables are summarized as counts and percentages and were compared by the chi-square or by Fisher exact test. Serum levels of MMPs were compared by Student t test or by Mann-Whitney U test. Pearson's correlation was used to correlate MMP levels with neointimal hyperplasia volume. Multiple logistic regression was used to evaluate the interaction between variables and MMPs in correlation with neointimal hyperplasia volume and in-stent restenosis. A stepwise entry procedure was applied to identify significant or suggestive (p < 0.1) confounders of either patient group or MMP level. Odds ratios were expressed with 95% confidence intervals. A p-value of less than 0.05 was considered statistically significant. All statistical analyses were performed with the statistical software package SPSS version 12.0 (SPSS, Inc., Chicago, Illinois). The authors had full access to the data and take responsibility for its integrity. All authors have read and agree to the manuscript as written.


Recruitment information / eligibility

Status Not yet recruiting
Enrollment 50
Est. completion date May 1, 2019
Est. primary completion date January 1, 2019
Accepts healthy volunteers No
Gender All
Age group 20 Years to 90 Years
Eligibility Inclusion Criteria:

- Ischemic heart disease

Exclusion Criteria:

- Left main coronary artery disease (defined as a stenosis of > 50%)

- Prior complex lesion morphologies (aorto-ostial, bifurcation with >2.0 mm side branch, severe calcification, chronic total occlusion)

- Long lesion that require more than two stents

- Inflammatory conditions likely to be associated with an acute phase response, autoimmune and neoplastic disease

- Advanced liver disease, renal failure, and valvular heart disease

- If there was persistent cardiogenic shock, refractory pulmonary edema, or hemodynamic instability (blood pressure <90/50 mmHg).

Study Design


Intervention

Device:
DES implantation
Coronary artery intervention using Drug eluting stent and Intravascular Ultrasound is performed.

Locations

Country Name City State
n/a

Sponsors (1)

Lead Sponsor Collaborator
Dankook University

References & Publications (2)

Katsaros KM, Kastl SP, Zorn G, Maurer G, Wojta J, Huber K, Christ G, Speidl WS. Increased restenosis rate after implantation of drug-eluting stents in patients with elevated serum activity of matrix metalloproteinase-2 and -9. JACC Cardiovasc Interv. 2010 Jan;3(1):90-7. doi: 10.1016/j.jcin.2009.10.023. — View Citation

Schoenhagen P, Vince DG, Ziada KM, Kapadia SR, Lauer MA, Crowe TD, Nissen SE, Tuzcu EM. Relation of matrix-metalloproteinase 3 found in coronary lesion samples retrieved by directional coronary atherectomy to intravascular ultrasound observations on coronary remodeling. Am J Cardiol. 2002 Jun 15;89(12):1354-9. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Matrix Metalloproteinase expression correlate with neointimal plaque volume measure by intravascular ultrasound at 12 months follow up coronary angiography Endogenous MMP-2 and MMP-9 were measured in serum using a standardized enzyme-linked immunosorbent assay (ELISA; R&D systems). This system measures the endogenous activity of the specific MMPs. Neointimal plaque volume measure by intravascular ultrasound at 12 months follow up coronary angiography One time frame - MMP sampling at 12 month follow up coronary angiography.
See also
  Status Clinical Trial Phase
Recruiting NCT06030596 - SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
Completed NCT04080700 - Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
Recruiting NCT03810599 - Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study N/A
Recruiting NCT06002932 - Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions. N/A
Not yet recruiting NCT06032572 - Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE) N/A
Recruiting NCT05308719 - Nasal Oxygen Therapy After Cardiac Surgery N/A
Recruiting NCT04242134 - Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions N/A
Completed NCT04556994 - Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients. N/A
Recruiting NCT05846893 - Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease N/A
Recruiting NCT06027788 - CTSN Embolic Protection Trial N/A
Recruiting NCT05023629 - STunning After Balloon Occlusion N/A
Completed NCT04941560 - Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
Completed NCT04006288 - Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease Phase 4
Completed NCT01860274 - Meshed Vein Graft Patency Trial - VEST N/A
Recruiting NCT06174090 - The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients N/A
Completed NCT03968809 - Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
Terminated NCT03959072 - Cardiac Cath Lab Staff Radiation Exposure
Recruiting NCT05065073 - Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography Phase 4
Recruiting NCT04566497 - Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up. N/A
Completed NCT05096442 - Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions N/A