Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT01760200
Other study ID # 0000003
Secondary ID
Status Completed
Phase N/A
First received December 16, 2012
Last updated January 2, 2013
Start date August 2012
Est. completion date December 2012

Study information

Verified date January 2013
Source Azienda Ospedaliero Universitaria Maggiore della Carita
Contact n/a
Is FDA regulated No
Health authority Italy: National Institute of Health
Study type Observational

Clinical Trial Summary

Drug eluting balloons (DEB) have been developed to overcome the limitations of drug eluting stent (DES), but clinical results of different studies about DEB are not consistent.

Thus, we planned a meta-analysis to compare outcomes of DEB and DES in coronary artery disease (CAD).


Description:

Drug eluting balloons (DEB) have been developed to overcome the limitations of drug eluting stent (DES), but clinical results of different studies about DEB are not consistent. Thus, we performed a meta-analysis to compare outcomes of DEB and DES in coronary artery disease (CAD).

The meta-analysis was performed according to the recommended methods [14-15]. A systematic search for eligible studies involved MEDLINE, CENTRAL, Embase, Highwire Press, Scopus and Google Scholar databases and was conducted without language restriction by two independent investigators (A.L. and A.R.), using the following keywords: "drug", "eluting" "balloon(s)", "DEB", "coronary", "angioplasty". Divergences were resolved by consensus. Endnote software v. 10 was used to build up libraries of results that were combined after erasing duplicates. The references of retrieved studies were searched manually for additional trials, and efforts to contact authors were performed to obtain further study details or additional references. The search is updated to December 2012.

Selection criteria: citations were screened at title and abstract level and retrieved as full reports.

- Inclusion criteria were: 1) randomized studies or cohort studies reporting a comparison between a DEB treated group and a DES treated group; 2) availability of reports of late lumen loss (LLL) and/or overall death and/or myocardial infarction (MI) and/or stent thrombosis (ST) and/or target lesion revascularization (TLR).

- Exclusion criteria were: 1) duplicate reporting (in which case the manuscript reporting the largest sample or the longest follow-up was selected), 2) follow up of at least 6 months; 3) studies presenting composite major adverse cardiac events (MACE) without mentioning individual end points. Data were abstracted on pre-specified forms by 2 unblinded reviewers; divergences were resolved by consensus.

Internal validity : the present meta-analysis was performed according to the Guidelines for randomized controlled trials of the Cochrane Collaboration and for non randomized studies in compliance with the Guidelines of the MOOSE group. Quality of included studies was appraised by 2 unblinded investigators. The risk of selection, performance, detection, and attrition bias (expressed as low risk of bias [A], moderate risk of bias [B], high risk of bias [C], or incomplete reporting leading to inability to ensure the underlying risk of bias [D]) were evaluated separately, as recommended. Non-randomized studies were evaluated using the Newcastle-Ottawa Scale a validated technique in assessing the quality of non-randomized studies.

Data analysis and synthesis: Odds ratios (ORs) were computed from individual studies and pooled according to a fixed effect (e.g. inverse variance weighting) or random effect model in case of statistical heterogeneity. Two separate subgroup analysis were pre-specified: 1) exclusion of studies with small vessel and bifurcation PCI; 2) exclusion of non-randomized studies 3) exclusion of studies in which DEBs were not used together with BMS deployment.

Results will be presented as overall meta-analysis and subgroups meta-analyses for DEB vs DES comparisons. Outcomes appraised were in-stent LLL, overall death, MI, ST and TLR. We used the Mantel-Haenszel method for combining ORs, a validated method to pool the data in a meta-analysis of binary outcomes. For the in-stent LLL outcome, the mean difference of 6-month LLL compared with baseline was used and the overall weighted mean difference (WMD) was built with the inverse variance method. Heterogeneity was assessed by Cochran's Q test, with 2-tailed p=0.1. Statistical inconsistency test (I2) was also employed to overcome the low statistical power of Cochran's Q test. The potential publication bias was examined by constructing a "funnel plot", in which sample size was plotted against odds ratios. In addition, a mathematical estimate of the asymmetry of this plot was provided by a linear regression approach. Asymmetry was considered to be present if the intercept of the regression line did deviate significantly from zero. To explore and mitigate heterogeneity, pre-specified covariates (prevalence of diabetes in the study population and reference coronary vessel diameter) as potential confounders were considered in the meta-regression analysis.

Pooling of data, subgroup analyses and publication bias tests were performed with Review Manager 5.1 (The Nordic Cochrane Center, Købehvn, Denmark) and StatsDirect v 2.7.8 (StatsDirect Ltd, Cheshire WA, UK). Meta-regression analyses were builded with Comprehensive Meta-analysis Version 2 (Biostat, Englewood, New Jersey, United States).


Recruitment information / eligibility

Status Completed
Enrollment 1462
Est. completion date December 2012
Est. primary completion date December 2012
Accepts healthy volunteers No
Gender Both
Age group 18 Years to 89 Years
Eligibility Inclusion Criteria:

- randomized studies or cohort studies reporting a comparison between a DEB treated group and a DES treated group

- availability of reports of late lumen loss (LLL) and/or overall death and/or myocardial infarction (MI) and/or stent thrombosis (ST) and/or target lesion revascularization (TLR).

Exclusion Criteria:

- duplicate reporting (in which case the manuscript reporting the largest sample or the longest follow-up was selected)

- follow up of at least 1 year

- studies presenting composite major adverse cardiac events (MACE) without mentioning individual end points.

Study Design

Time Perspective: Retrospective


Locations

Country Name City State
Italy Azienda Ospedaliero Universitaria Maggiore della Carita Novara Piedmont

Sponsors (1)

Lead Sponsor Collaborator
Azienda Ospedaliero Universitaria Maggiore della Carita

Country where clinical trial is conducted

Italy, 

Outcome

Type Measure Description Time frame Safety issue
Primary Overall mortality mortality rate from all cause 1 year No
Secondary Myocardial infarction rates Myocardial infarction rates 1 year No
Secondary Target vessel revascularization symptoms or ischemia driven new revascularization of the coronary artery already treated with DEB at baseline 1 year No
See also
  Status Clinical Trial Phase
Recruiting NCT06030596 - SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
Completed NCT04080700 - Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
Recruiting NCT03810599 - Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study N/A
Recruiting NCT06002932 - Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions. N/A
Not yet recruiting NCT06032572 - Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE) N/A
Recruiting NCT04242134 - Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions N/A
Recruiting NCT05308719 - Nasal Oxygen Therapy After Cardiac Surgery N/A
Completed NCT04556994 - Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients. N/A
Recruiting NCT05846893 - Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease N/A
Recruiting NCT06027788 - CTSN Embolic Protection Trial N/A
Recruiting NCT05023629 - STunning After Balloon Occlusion N/A
Completed NCT04941560 - Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
Completed NCT04006288 - Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease Phase 4
Completed NCT01860274 - Meshed Vein Graft Patency Trial - VEST N/A
Recruiting NCT06174090 - The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients N/A
Terminated NCT03959072 - Cardiac Cath Lab Staff Radiation Exposure
Completed NCT03968809 - Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
Recruiting NCT05065073 - Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography Phase 4
Recruiting NCT04566497 - Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up. N/A
Completed NCT05096442 - Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions N/A