Coronary Artery Disease Clinical Trial
Official title:
ComparisiOn of Neointimal coVerage betwEen zotaRolimus Eluting Stent and Everolimus Eluting Stent Using Optical Coherence Tomography at 9 Months (COVER OCT)
Stent thrombosis is an important issue in drug eluting stents. Incomplete endothelial coverage and neointimal coverage over strut after drug eluting stent (DES) implantation could be a possible cause of stent thrombosis. Therefore, theoretically dual antiplatelet therapy should be continued to prevent the stent thrombosis until complete reendothelialization. But, detection of endothelial coverage over stent is not possible with the available intravascular devices in clinical practice. Among currently available intravascular devices, intravascular optical coherence tomography (OCT) could give a more clear identification for a thin layer of neointima with high-resolution (10-20 μm) compared to intravascular ultrasound (100-150 μm). Previous OCT studies showed the significant different pattern of neointimal coverage between bare metal stent (BMS) and DES. In the investigators' experience, there were also some differences in neointimal coverage among the DESs, especially zotarolimus eluting stent (ZES). ZES has been known to be associated with significantly more neointimal coverage than SES at 8 months intravascular ultrasound (IVUS). Both everolimus eluting stent (EES) and ZES resolute were recently introduced. The efficacy to suppress the neointimal growth for ZES resolute and EES might be improved, but safety for neointimal coverage needs to evaluate in human coronary artery. Therefore, this study will investigate the pattern of neointimal coverage over stent in ZES resolute and EES at 9 months after stent implantation.
Recent autopsy study showed the most important histological and morphometric predictors of
stent thrombosis were endothelial coverage and the ratio of uncovered to total strut after
drug eluting stent (DES) implantation. Although there have been some controversies,
incomplete stent apposition might be possible cause of very late stent thrombosis after DES
implantation. Therefore, theoretically dual antiplatelet therapy should be continued to
prevent the stent thrombosis until complete reendothelialization. But, detection of
endothelial coverage over stent are no possible with available intravascular devices in
clinical practice. Among currently available intravascular devices, intravascular optical
coherence tomography (OCT) could give a more clear identification for a thin layer of NIH
and malapposition with high-resolution (10 -20 μm) compared to intravascular ultrasound
(100-150 μm). Previous OCT studies showed the significant different pattern of neointimal
coverage between bare metal stent (BMS) and DES. In our experience, there was also some
differences in neointimal coverage among the DESs, especially zotarolimus eluting stent
(ZES). ZES have been known to be associated with significantly more neointimal coverage than
SES at 8 months intravascular ultrasound (IVUS). This finding might be related with strut
thickness and drug elution property. In our data, neointima was covered at 99.7% of stent
strut in ZES, but 93.2% in sirolimus eluting stent (SES) at 9 month follow OCT. This
difference was more distinct in patients with acute myocardial infarction (99.3% in ZES
vs.79.9% in SES).
Both everolimus eluting stent (EES) was recently introduced and ZES resolute also will be
available in the near future in Korea. Previous phosphorylcholine polymer was replaced with
new, proprietary polymer which can provide extended elution kinetics in ZES resolute.
Therefore, efficacy to suppress the neointimal growth might be improved but, safety for
neointimal coverage needs to evaluate in human coronary artery. Both new DESs are cobalt
chromium stent with thin stent strut and reported similar efficacy for suppressing the
neointima growth. Also, endothelial coverage over stent strut occurred earlier compared to
previous DESs (SES or PES) in animal experiments. But, there has been no data for neointimal
coverage and malapposition of ZES resolute and EES using OCT in human coronary artery.
Recent paper according to Kubo et al reported that serial OCT examinations demonstrated
markedly different vascular response up to 9 months after SES implantation between unstable
angina and stable angina patients. These findings implied that initial native vessel status,
which covered with stent, might be important and related with neointimal coverage and
malapposition. But, there is little data evaluated the relationship between initial lesion
status and neointimal coverage or late malapposition with OCT.
Therefore, this study investigates: 1) the relationship of the initial lesion and neointimal
coverage or late malapposition and 2) the neointimal coverage and malapposition at 9 month
after ZES resolute and EES implantation and 3) compare them between ZES resolute and EES at
9 months after stent implantation.
Study Objectives:
This study is a prospective open labeled randomized study to compare the neointimal coverage
of ZES resolute (Endeavor® resolute) and EES (Xience®) in 9 month after stent implantation
by OCT.
1. Primary end point:
- The primary endpoint is to compare the neointimal coverage of ZES resolute
(Endeavor® resolute) and EES (Xience®) at 9 months after stent implantation by
OCT.
2. Secondary end points:
- To investigate the relationship between initial lesion and neointimal coverage and
malapposition at 9 months, and
- To compare of neointimal growth between ZES resolute and EES at 9 months and to
compare the difference in early and late malapposition between ZES resolute and
EES at 9 months.
;
Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Parallel Assignment, Masking: Open Label, Primary Purpose: Treatment
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Recruiting |
NCT06030596 -
SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
|
||
| Completed |
NCT04080700 -
Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
|
||
| Recruiting |
NCT03810599 -
Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study
|
N/A | |
| Recruiting |
NCT06002932 -
Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions.
|
N/A | |
| Not yet recruiting |
NCT06032572 -
Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE)
|
N/A | |
| Recruiting |
NCT05308719 -
Nasal Oxygen Therapy After Cardiac Surgery
|
N/A | |
| Recruiting |
NCT04242134 -
Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions
|
N/A | |
| Completed |
NCT04556994 -
Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients.
|
N/A | |
| Recruiting |
NCT05846893 -
Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease
|
N/A | |
| Recruiting |
NCT06027788 -
CTSN Embolic Protection Trial
|
N/A | |
| Recruiting |
NCT05023629 -
STunning After Balloon Occlusion
|
N/A | |
| Completed |
NCT04941560 -
Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
|
||
| Completed |
NCT04006288 -
Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease
|
Phase 4 | |
| Completed |
NCT01860274 -
Meshed Vein Graft Patency Trial - VEST
|
N/A | |
| Recruiting |
NCT06174090 -
The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients
|
N/A | |
| Terminated |
NCT03959072 -
Cardiac Cath Lab Staff Radiation Exposure
|
||
| Completed |
NCT03968809 -
Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
|
||
| Recruiting |
NCT04566497 -
Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up.
|
N/A | |
| Recruiting |
NCT05065073 -
Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography
|
Phase 4 | |
| Completed |
NCT05096442 -
Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions
|
N/A |