Coronary Artery Disease Clinical Trial
Official title:
The eSVS(TM)Mesh External Saphenous Vein Support Trial
Prospective, multi-center, randomized, controlled (patients as their own control) trial on an external mesh device (eSVS™, Kips Bay Medical) supporting saphenous vein grafts for coronary bypass graft surgery in patients with multi-vessel coronary heart disease.
The objective of the eSVS™ Mesh Saphenous Vein Support Trial is to prospectively evaluate
the clinical safety and efficacy of the eSVS™ Mesh for the treatment of Saphenous Vein Graft
(SVG) Coronary artery bypass grafting (CABG) versus SVG CABG without an eSVS™ Mesh.
The eSVS™ Mesh External Saphenous Vein Support Trial is a prospective, multi-center,
randomized, controlled trial enrolling up to 120 patients with multi-vessel coronary artery
disease who require SVG CABG of the Right Coronary Artery and the Circumflex Artery due to
atherosclerotic coronary artery disease. Patients will serve as their own control (patients
will be randomized to either:
1. SVG+eSVS™ Mesh at Right Coronary Artery and SVG at Circumflex Artery or
2. SVG at Right Coronary Artery and SVG+eSVS™ Mesh at Circumflex Artery).
Clinical follow-up assessments consisting of a physical exam, laboratory testing, medication
review, and adverse event monitoring for all enrolled patients will be performed at 30 days,
6 months and 12 months. In addition, the 12 month follow-up assessment will include
angiography.
The investigational device being evaluated in this clinical trial is an External Saphenous
Vein Support device, the eSVS™ Mesh.
The eSVS™ Mesh is an extravascular prosthesis consisting of a highly flexible,
semi-compliant knitted nitinol mesh tube that is placed over the patient's saphenous vein
graft (SVG) during coronary artery bypass grafting (CABG). The eSVS™ Mesh is designed to:
- provide radial support to the vein to prevent graft dilatation
- reduce the vein graft diameter to more closely match target coronary artery diameter
- provide a more uniform lumen
- improve blood flow characteristics
- mitigate the development of intimal hyperplasia and graft stenosis
The eSVS™ Mesh has compliance characteristics comparable to native internal thoracic
arteries. Since the eSVS™ Mesh vascular prosthesis is made of nitinol, it is highly kink
resistant.
;
Endpoint Classification: Safety/Efficacy Study, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Treatment
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Recruiting |
NCT06030596 -
SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
|
||
| Completed |
NCT04080700 -
Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
|
||
| Recruiting |
NCT03810599 -
Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study
|
N/A | |
| Recruiting |
NCT06002932 -
Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions.
|
N/A | |
| Not yet recruiting |
NCT06032572 -
Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE)
|
N/A | |
| Recruiting |
NCT05308719 -
Nasal Oxygen Therapy After Cardiac Surgery
|
N/A | |
| Recruiting |
NCT04242134 -
Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions
|
N/A | |
| Completed |
NCT04556994 -
Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients.
|
N/A | |
| Recruiting |
NCT05846893 -
Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease
|
N/A | |
| Recruiting |
NCT06027788 -
CTSN Embolic Protection Trial
|
N/A | |
| Recruiting |
NCT05023629 -
STunning After Balloon Occlusion
|
N/A | |
| Completed |
NCT04941560 -
Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
|
||
| Completed |
NCT04006288 -
Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease
|
Phase 4 | |
| Completed |
NCT01860274 -
Meshed Vein Graft Patency Trial - VEST
|
N/A | |
| Recruiting |
NCT06174090 -
The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients
|
N/A | |
| Terminated |
NCT03959072 -
Cardiac Cath Lab Staff Radiation Exposure
|
||
| Completed |
NCT03968809 -
Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
|
||
| Recruiting |
NCT05065073 -
Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography
|
Phase 4 | |
| Recruiting |
NCT04566497 -
Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up.
|
N/A | |
| Completed |
NCT05096442 -
Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions
|
N/A |