Coronary Artery Disease Clinical Trial
Official title:
PET and Recovery Following Revascularization: Outcome and Cost-effectiveness of FDG PET in Left Ventricular Dysfunction (PARR 2)
Rationale: Patients with severe ventricular dysfunction and coronary disease have high
morbidity and mortality. They may benefit from revascularization, but have significant
peri-operative morbidity and mortality. Positron emission tomography (PET) imaging with
F-18-fluorodeoxyglucose (FDG) can detect viable myocardium that may recover from
revascularization in such patients. It is unclear whether use of FDG PET in this population
is improves outcome or is cost-effective.
Objectives: The principal aim is to determine whether FDG PET-guided therapy is effective
versus standard care. Secondary objectives are to determine whether FDG PET-guided therapy
improves LV function, quality of life and is good value for money versus standard care.
Patients with severe ventricular dysfunction and coronary artery disease have high morbidity and mortality but may benefit from revascularization. However, there is also significant peri-operative morbidity and mortality among these patients. This accounts for the variable approach to these patients in different cardiac centres. Clearly this patient group has the most to gain when coronary revascularization is beneficial, but also the most to lose when it is not helpful. There is a need for an approach that can better define patients with severe ventricular dysfunction due to ischemia, who will be more likely to benefit from revascularization. Positron emission tomography (PET) imaging with F-18-Fluorodeoxyglucose (FDG) has been used to evaluate patients with ventricular dysfunction, to detect ischemic but viable myocardium more likely to recover from revascularization. Recently retrospective studies have shown that FDG PET can identify patients at high risk for cardiac events if they do not undergo revascularization. However, these studies did not evaluate whether FDG PET actually directed therapy decisions and because of their study design, could not determine whether FDG PET altered patient outcome. Our recent studies have shown that FDG PET can have important impact on therapy decisions and that patients with ischemic but viable myocardium are at increased risk. However it remains unclear whether an approach which utilizes FDG PET to define ischemic but viable myocardium can have a beneficial effect on patient outcome. It is also important to consider the potential clinical impact of FDG PET balanced against its limited availability. In addition, despite the cost of the technology, preliminary data from our group and others suggest a potential cost savings. Accordingly, a prospective randomized study is needed to evaluate whether FDG PET directed therapy has a beneficial effect on patient outcome and is cost-effective. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT06030596 -
SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
|
||
Completed |
NCT04080700 -
Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
|
||
Recruiting |
NCT03810599 -
Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study
|
N/A | |
Recruiting |
NCT06002932 -
Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions.
|
N/A | |
Not yet recruiting |
NCT06032572 -
Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE)
|
N/A | |
Recruiting |
NCT04242134 -
Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions
|
N/A | |
Recruiting |
NCT05308719 -
Nasal Oxygen Therapy After Cardiac Surgery
|
N/A | |
Completed |
NCT04556994 -
Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients.
|
N/A | |
Recruiting |
NCT05846893 -
Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease
|
N/A | |
Recruiting |
NCT06027788 -
CTSN Embolic Protection Trial
|
N/A | |
Recruiting |
NCT05023629 -
STunning After Balloon Occlusion
|
N/A | |
Completed |
NCT04941560 -
Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
|
||
Completed |
NCT04006288 -
Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease
|
Phase 4 | |
Completed |
NCT01860274 -
Meshed Vein Graft Patency Trial - VEST
|
N/A | |
Recruiting |
NCT06174090 -
The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients
|
N/A | |
Terminated |
NCT03959072 -
Cardiac Cath Lab Staff Radiation Exposure
|
||
Completed |
NCT03968809 -
Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
|
||
Recruiting |
NCT04566497 -
Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up.
|
N/A | |
Recruiting |
NCT05065073 -
Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography
|
Phase 4 | |
Completed |
NCT05096442 -
Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions
|
N/A |