Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT00292474
Other study ID # S2004
Secondary ID TAXUS IV
Status Completed
Phase Phase 2/Phase 3
First received February 14, 2006
Last updated October 7, 2008
Start date March 2002
Est. completion date August 2007

Study information

Verified date October 2008
Source Boston Scientific Corporation
Contact n/a
Is FDA regulated No
Health authority United States: Food and Drug Administration
Study type Interventional

Clinical Trial Summary

The ultimate goal of a paclitaxel eluting stent system (TAXUS stent) is to prevent restenosis by blunting the initial response to stent implant injury and sustaining the arrested response until vascular healing has taken place.

The purpose of the TAXUS IV-SR trial is to study the safety and efficacy of the TAXUS Stent under controlled trial circumstances used in the treatment of new coronary artery lesions (heart blockages) This clinical investigation will evaluate the safety and effectiveness of the TAXUS Stent with 1 ug/mm2 (loaded drug/stent surface area) of paclitaxel incorporated into a slow rate-release formulation of a triblock copolymer carrier system for treatment of new coronary artery lesions.


Description:

This was a prospective randomized, double-blind, multicenter safety and efficacy trial. Patients were stratified by presence or absence of medically treated diabetes mellitus and vessel diameter (<3.0 mm or >/=3.0 mm), then randomized 1:1 to receive either the TAXUS Stent or a Control stent. Additional study stents were permitted to optimize outcomes. The study was considered complete (with regard to the primary endpoint) after all patients enrolled had completed the 9 month follow-up.

Enrollment of 1172 patients was planned; 1326 were treated and randomized at 73 centers involving 76 sites by 8 July 2002 with 667 in the TAXUS group and 659 in the Control group.


Recruitment information / eligibility

Status Completed
Enrollment 1326
Est. completion date August 2007
Est. primary completion date August 2007
Accepts healthy volunteers No
Gender Both
Age group 18 Years and older
Eligibility Inclusion Criteria:

1. Patient is > or = 18 years old

2. Eligible for percutaneous coronary intervention (PCI)

3. Documented stable angina pectoris (Canadian Cardiovascular Society Classification [CCS] 1, 2, 3, or 4) or unstable angina pectoris with documented ischemia (Braunwald Class IB-C, IIB-C, or IIIB-C), or documented silent ischemia

4. Left ventricular ejection fraction (LVEF) of > or = 25%

5. Acceptable candidate for CABG

6. Patient (or legal guardian) understands the study requirements and the treatment procedures and provides written Informed Consent before any study-specific tests or procedures are performed

7. Willing to comply with all specified follow-up evaluations

1. Target lesion located within a single native coronary vessel 2. Target lesion randomized to treatment with the study device may be composed of multiple lesions but must be completely coverable by one (1) study stent 3. Cumulative target lesion length is > or = 10 mm and < or = 28 mm (visual estimate) 4. RVD of > or = 2.5mm to < or = 3.75 mm (visual estimate) 5. Target lesion diameter stenosis > or = 50% (visual estimate) 6. Target lesion is de novo (i.e., a coronary lesion not previously treated)

7. Target lesion located within a single native coronary vessel 8. Target lesion randomized to treatment with the study device may be composed of multiple lesions but must be completely coverable by one (1) study stent 9. Cumulative target lesion length is > or = 10 mm and < or = 28 mm (visual estimate) 10. RVD of > or = 2.5mm to < or = 3.75 mm (visual estimate) 11. Target lesion diameter stenosis > or = 50% (visual estimate) 12. Target lesion is de novo (i.e., a coronary lesion not previously treated)

Exclusion Criteria:

1. Known sensitivity to paclitaxel 2. Any previous or planned treatment with a non-study anti-restenotic drug-coated or drug-eluting coronary stent. (Note: previous or planned treatment with heparin or phosphorylcholine coated stents is acceptable, as long as the procedure with the non-study stent meets the protocol defined criteria for staged procedures) 3. Previous or planned treatment with intravascular brachytherapy in the target vessel 4. MI within 72 hours prior to the index procedure and/or CK-MB >2x the local laboratory's upper limits of normal (refers to a measured value on the day of the index procedure) 5. Cerebrovascular Accident (CVA) within the past 6 months 6. Acute or chronic renal dysfunction (creatinine >2.0 mg/dl or >150 µmol/L) 7. Contraindication to ASA, or to both clopidogrel and ticlopidine 8. Leukopenia (leukocyte count <3.5 x 109/liter) 9. Thrombocytopenia (platelet count <100,000/mm3) 10. Active peptic ulcer or active gastrointestinal (GI) bleeding 11. Known allergy to stainless steel 12. Any prior true anaphylactic reaction to contrast agents 13. Known anaphylactoid or other non-anaphylactic allergic reactions to contrast agents that cannot be adequately pre-medicated prior to the index procedure 14. Patient is currently taking colchicine 15. Patient is currently, or has been treated with paclitaxel within 12 months of the index procedure 16. Female of childbearing potential with a positive pregnancy test within 7 days before the index procedure, or lactating, or intends to become pregnant during the study 17. Life expectancy of less than 24 months due to other medical conditions 18. Co-morbid condition(s) that could limit the patient's ability to participate in the study, compliance with follow-up requirements or impact the scientific integrity of the study 19. Currently participating in another investigational drug or device study that has not completed the primary endpoint or that clinically interferes with the endpoints of this study

Study Design

Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Parallel Assignment, Masking: Double Blind (Subject, Investigator), Primary Purpose: Treatment


Intervention

Device:
percutaneous coronary intervention


Locations

Country Name City State
United States Stephen G.Ellis Cleveland Ohio

Sponsors (1)

Lead Sponsor Collaborator
Boston Scientific Corporation

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Primary The primary objective of this study is to evaluate the safety and effectiveness of the TAXUS Stent System with 1 ug/mm2 (loaded drug/stent surface area) of paclitaxel incorporated into a slow rate-release formulation of a triblock copolymer carrier syst
Secondary Secondary endpoints include the following:
Secondary • Rates of composite MACE and the individual components of MACE (MI, TVR, Cardiac Death), assessed at 1, 4 and 9 months after the index procedure and annually for 5 more years (i.e., 1, 2, 3, 4, and 5 years after the index procedure).
Secondary • Stent thrombosis rate
Secondary • Target Vessel Failure
Secondary • Clinical procedural success
Secondary • Binary restenosis rate
See also
  Status Clinical Trial Phase
Recruiting NCT06030596 - SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
Completed NCT04080700 - Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
Recruiting NCT03810599 - Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study N/A
Recruiting NCT06002932 - Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions. N/A
Not yet recruiting NCT06032572 - Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE) N/A
Recruiting NCT05308719 - Nasal Oxygen Therapy After Cardiac Surgery N/A
Recruiting NCT04242134 - Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions N/A
Completed NCT04556994 - Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients. N/A
Recruiting NCT05846893 - Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease N/A
Recruiting NCT06027788 - CTSN Embolic Protection Trial N/A
Recruiting NCT05023629 - STunning After Balloon Occlusion N/A
Completed NCT04941560 - Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
Completed NCT04006288 - Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease Phase 4
Completed NCT01860274 - Meshed Vein Graft Patency Trial - VEST N/A
Recruiting NCT06174090 - The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients N/A
Completed NCT03968809 - Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
Terminated NCT03959072 - Cardiac Cath Lab Staff Radiation Exposure
Recruiting NCT04566497 - Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up. N/A
Recruiting NCT05065073 - Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography Phase 4
Completed NCT05096442 - Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions N/A