Coronary Artery Disease Clinical Trial
Official title:
Predicting Fluid Responsiveness in on Pump Coronary Artery Bypass Graft Using Extra Systoles and Investigation of a Novel Mini Fluid Challenge Ability to Predict Fluid Responsiveness
The purpose of this study is to determine if extra systoles can be used to predict fluid responsiveness perioperatively in patients undergoing on pump coronary artery bypass graft (CABG) surgery. As an additional study we will investigate the ability of a mini fluid challenge to predict response of a larger volume of fluid.
From induction of anaesthesia to cardioplegia we will serve two fluid challenges. Before and
after each challenge we will collect hemodynamic data and use this to asses our two
hypotheses.
Fluid responsiveness (the outcome to predict) will be defined as a 15% increase in stroke
volume(SV) from immediately before fluid infusion is initiated (baseline) to after the full
fluid infusion. Stroke volume is derived from the gold-standard pulmonary artery catheter
measurement of cardiac output(CO), which is standard monitoring for these patients (SV =
CO/heart rate). From subsequent offline analysis of the extracted curve data we will
investigate if post-ectopic characteristics from identified extra systoles during the
baseline period can predict fluid responsiveness (i.e. the SV change). This analysis
addresses the primary hypothesis. Also, we will analyse the arterial waveform related to the
mini fluid challenge for morphologic changes (comparing heart beats before the infusion with
heart beats during the infusion) and see if such transient changes, e.g. in systolic blood
pressure, are able to predict fluid responsiveness. This analysis addresses the secondary
hypothesis.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT06030596 -
SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
|
||
Completed |
NCT04080700 -
Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
|
||
Recruiting |
NCT03810599 -
Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study
|
N/A | |
Recruiting |
NCT06002932 -
Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions.
|
N/A | |
Not yet recruiting |
NCT06032572 -
Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE)
|
N/A | |
Recruiting |
NCT05308719 -
Nasal Oxygen Therapy After Cardiac Surgery
|
N/A | |
Recruiting |
NCT04242134 -
Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions
|
N/A | |
Completed |
NCT04556994 -
Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients.
|
N/A | |
Recruiting |
NCT05846893 -
Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease
|
N/A | |
Recruiting |
NCT06027788 -
CTSN Embolic Protection Trial
|
N/A | |
Recruiting |
NCT05023629 -
STunning After Balloon Occlusion
|
N/A | |
Completed |
NCT04941560 -
Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
|
||
Completed |
NCT04006288 -
Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease
|
Phase 4 | |
Completed |
NCT01860274 -
Meshed Vein Graft Patency Trial - VEST
|
N/A | |
Recruiting |
NCT06174090 -
The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients
|
N/A | |
Terminated |
NCT03959072 -
Cardiac Cath Lab Staff Radiation Exposure
|
||
Completed |
NCT03968809 -
Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
|
||
Recruiting |
NCT04566497 -
Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up.
|
N/A | |
Recruiting |
NCT05065073 -
Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography
|
Phase 4 | |
Completed |
NCT05096442 -
Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions
|
N/A |