Clinical Trials Logo

Clinical Trial Summary

The main goal of this prospective pre-post implementation study is to investigate how a structured testing and treatment program for obstructive sleep apnea using the NOX T3s device and a Fitbit smartwatch with the FibriCheck algorithm impacts the proportion of atrial fibrillation (AF) in an AF population. Participants will wear the NOX T3s respiratory polygraphy device for one night at home. In case of a positive obstructive sleep apnea diagnosis, patients will be referred to the sleep clinic for a polysomnography examination. Patients positively diagnosed with polygraph will be monitored semi-continuously with the Fitbit smartwatch for three months. After the polysomnography examination, the positively diagnosed patients will be monitored semi-continuously for another three months after initiation of treatment (mostly continuous positive airway pressure (CPAP) treatment). Additionally, patients will be administered satisfaction and symptom burden questionnaires twice: right after the polysomnography examination and after the 3-month treatment.


Clinical Trial Description

Atrial fibrillation (AF) is the most prevalent arrhythmia globally. Research has shown that AF is associated with various risk factors such as hypertension, diabetes, obesity, and obstructive sleep apnea. Obstructive sleep apnea is a sleep-disordered breathing condition that is highly prevalent in AF patients, contributing to the development and progression of AF. Despite the high prevalence of obstructive sleep apnea in AF patients (about 62%), it often goes underrecognized and underdiagnosed. Lack of symptom reporting and easily accessible screening tools and strategies contribute to this underdiagnosis. The standard diagnostic method is through polysomnography, which, while effective, has drawbacks such as high costs, labor intensity, and time-consuming nature, making it challenging to use as a screening tool. (Cardio)respiratory polygraphy devices, such as the NOX-T3s, are gaining interest for obstructive sleep apnea detection due to their user-friendly nature, comfort, convenience, and home useability. A previous validation study showed that the NOX-T3s polygraphy device had high accuracy, sensitivity, and specificity and was also the most user-friendly for obstructive sleep apnea detection in AF patients. Besides the screening, retrospective research has shown that obstructive sleep apnea treatment with the gold standard method, continuous positive airway pressure (CPAP), positively influences AF recurrence through improved antiarrhythmic therapy. Current literature suggests early obstructive sleep apnea diagnosis, followed by early CPAP treatment, could reduce AF recurrence. However, prospective studies supporting this are lacking. Therefore, additional information on the heart rhythm of AF patients, monitored in a (semi)-continuous manner before and after treatment initiation, would be valuable to investigate if treatment (mostly CPAP) leads to a reduction in AF events. However, implementing a care pathway using the NOX T3s for structured obstructive sleep apnea testing and the Fitbit Versa smartwatch with the FibriCheck algorithm for the follow-up of AF recurrence in standard clinical care in an AF population still needs to be evaluated. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06263608
Study type Interventional
Source University Hospital, Antwerp
Contact Lien Desteghe, MSc, PhD
Phone +32 3 821 33 06
Email lien.desteghe@uza.be
Status Recruiting
Phase N/A
Start date February 23, 2024
Completion date February 2028

See also
  Status Clinical Trial Phase
Recruiting NCT05654272 - Development of CIRC Technologies
Completed NCT04571385 - A Study Evaluating the Efficacy and Safety of AP30663 for Cardioversion in Participants With Atrial Fibrillation (AF) Phase 2
Terminated NCT04115735 - His Bundle Recording From Subclavian Vein
Completed NCT05366803 - Women's Health Initiative Silent Atrial Fibrillation Recording Study N/A
Completed NCT02864758 - Benefit-Risk Of Arterial THrombotic prEvention With Rivaroxaban for Atrial Fibrillation in France
Recruiting NCT05442203 - Electrocardiogram-based Artificial Intelligence-assisted Detection of Heart Disease N/A
Completed NCT05599308 - Evaluation of Blood Pressure Monitor With AFib Screening Feature N/A
Completed NCT03790917 - Assessment of Adherence to New Oral anTicoagulants in Atrial Fibrillation patiEnts Within the Outpatient registrY
Enrolling by invitation NCT05890274 - Atrial Fibrillation (AF) and Electrocardiogram (EKG) Interpretation Project ECHO N/A
Recruiting NCT05316870 - Construction and Effect Evaluation of Anticoagulation Management Model in Atrial Fibrillation N/A
Recruiting NCT05266144 - Atrial Fibrillation Patients Treated With Catheter Ablation
Not yet recruiting NCT06023784 - The Impact of LBBAP vs RVP on the Incidence of New-onset Atrial Fibrillation in Patients With Atrioventricular Block N/A
Recruiting NCT05572814 - Transform: Teaching, Technology, and Teams N/A
Recruiting NCT04092985 - Smart Watch iECG for the Detection of Cardiac Arrhythmias
Completed NCT04087122 - Evaluate the Efficiency Impact of Conducting Active Temperature Management During Cardiac Cryoablation Procedures N/A
Completed NCT06283654 - Relieving the Emergency Department by Using a 1-lead ECG Device for Atrial Fibrillation Patients After Pulmonary Vein Isolation
Recruiting NCT05416086 - iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study N/A
Completed NCT05067114 - Solutions for Atrial Fibrillation Edvocacy (SAFE)
Completed NCT04546763 - Study Watch AF Detection At Home
Completed NCT03761394 - Pulsewatch: Smartwatch Monitoring for Atrial Fibrillation After Stroke N/A