View clinical trials related to Atrial Fibrillation.
Filter by:This is a prospective randomized controlled trial that compares the conventional stepwise approach with a new sequential substrate ablation approach for persistent atrial fibrillation.
Prospective mono-center diagnostic study determining potential discrepancies in identifying atrial fibrillation by intraindividually comparing different types of follow-up strategies: 1. How many stroke patients with atrial fibrillation are missed by standard stroke unit 24h- electrocardiography, and 2. what is the effectiveness of the extended invasive and non-invasive ECG analysis tools to detect atrial fibrillation in stroke patients?
The purpose of this study is to evaluate the APIXABAN use in the Prevention of Stroke and Systemic Embolism in Patients with Atrial Fibrillation in Real-Life Setting in France, data from SNIIRAM (French data base).
We randomly assigned 390 patients with symptomatic, paroxysmal AF to undergo catheter ablation with PVI (PVI group) alone or combined with 6 additional ablation lines extended outside the PVI circumferences at 1, 3 and 6 o'clock of left PV and 6, 9 and 11 o'clock of right PV (PVI+6L group). Patients received monthly 12-lead electrocardiogram, 24-hour Holter at 3, 6 and 9 months and 14-days continuous monitoring at 12 months to detect atrial tachyarrhythmia. The follow-up period was 12 months. The primary end point was freedom from AF recurrence between 91 and 365 days after catheter ablation. The secondary end points included the AF burden, procedural parameters, and complications.
The purpose of this study is to determine if an eight week multimodal Relaxation Response Resiliency Program (3RP) intervention can effectively improve symptom severity, frequency and quality of life (Q.O.L) in atrial fibrillation (AF) patients. This will be measured by a reduction in AF symptom score, perceived stress, anxiety, hostility and depression.
The primary objective of this study is to compare the Length of Stay from treatment of oral anticoagulant initiation to hospital discharge of patients hospitalized and subsequently treated with dabigatran or warfarin for non-valvular atrial fibrillation in a real-world Japanese clinical practice. The secondary objective of the study is to compare LoS of patients hospitalized with 1) acute ischemic stroke, and 2) due to non-valvular atrial fibrillation. Other objectives are (1) to compare the in-hospital direct and indirect-related costs between dabigatran and warfarin, and (2) to compare the rates of patients directly discharged at home after the index hospitalization between dabigatran and warfarin.
The objective of the study is to investigate the feasibility of a hybrid procedure removal of the atrial fibrillation. This is a single procedure for both surgical epicardial by minimally invasive route (Thoracoscopy) without even flow controlled and supplemented if necessary by extra corporeal intracavitary route at the same time. This faster procedure combined with complete lesions have a higher success rate and less frequent re-hospitalizations of patients.
The primary purpose of the FIN-bioAVR registry is to assess the incidence of AF, strokes and major bleeding events in patients undergoing aortic valve replacement. This retrospective multicenter registry will include 850 patients with aortic valve replacement using bioprosthesis.
Patients with implantable heart devices including pacemakers, defibrillators, and cardiac monitors may not seek regular medical care related to their implanted devices. These devices are capable of detecting abnormal heart rhythms or other device abnormalities that may benefit from clinical action or oversight. A novel healthcare information technology has been developed and is being implemented clinically for screening of patients with cardiac rhythm devices who seek care in the emergency room setting. This study seeks to examine differences in detection of cardiac rhythm disturbances including atrial fibrillation (AF) with utilization of this new screening technology, and how often treatment plans change in patients who have a heart rhythm abnormality detected.
Atrial fibrillation (AF) is a very common abnormal heart rhythm, triggered by rapid electrical activity originating from the pulmonary veins (PVs) that drain blood from the lungs back to the left atrium (LA). Ablation of the junction between the PVs and the LA, electrically isolating the veins from the heart, is the key to prevent AF. When using radiofrequency energy (RF), transmural lesions are required to achieve permanent pulmonary vein isolation (PVI). New technologies are currently available to predict the ablation lesion depth and to guide the duration of each application. However, deeper lesions mean a higher risk of overheating and damage of adjacent structures such as the esophagus that lies against the back wall of the LA. In order to minimize this risk, the investigators continuously monitor the temperature inside the esophagus during the procedure through a probe placed in the esophagus and they promptly terminate energy delivery in case of any esophageal temperature rises more than 39°C. To date, it is not known if a low power for a longer time is better than a high power for a shorter time when ablating on the LA posterior wall in order to create permanent scars without heating the esophagus. Therefore, the investigators plan to compare the incidence of esophageal temperature alerts and the success of the procedure with four different energy settings during ablation on the LA posterior wall.