View clinical trials related to Apnea.
Filter by:Prospective, randomized controlled trial. Pregnant women in early pregnancy will be randomized to either the Sleep Study + CPAP (Continuous Positive Airway Pressure Therapy) group or to a Standard Prenatal Care group. Subjects in the Sleep Study + CPAP group will complete a sleep study (WatchPAT-200, Itamar Medical, Inc.) and have CPAP initiated if the Apnea Hypopnea Index (AHI) ≥5 as indicated, in early and late pregnancy, whereas the other group will receive standard prenatal care. All subjects will complete a sleep study again between 8 to 12 weeks postpartum.
ESTAMPS is a randomized clinical trial with a crossover design: Main objective is to compare impact of 2 different Mandibular Retention Device (MRD) designs (Narval MRD CadCam (CC) design vs Narval MRD traditional (trad) design) on upper airway volume secondary objectives: To evaluate the maximal mandibular propulsion according to the type of MRD To evaluate benefits on quality of life, sleepiness and OSA symptoms To evaluate impact of MRD design on therapy efficacy and tolerance To evaluate impact of MRD design on mandibular positioning
This is a randomized clinical trial investigating the utility of apneic oxygenation via nasal cannulae in the post-induction setting for the purpose of prolonging the safe apneic time. Three groups will be compared, a control group at 0 L/min, a 15 L/min and a 60 L/min group. The primary outcome will be the difference in the partial pressure of oxygen in arterial blood (PaO2) between groups throughout the nine-minute apneic period.
Little is known about potential relationships between sleep apnea, plasma aldosterone and diastolic dysfunction which is a very frequent finding among patients requiring permanent cardiac pacing. Sleep apnea is often under diagnosed by clinical examination. Confirmation tests are expensive and access is limited. A specific algorithm available in a recent pacemaker allows assessing breathing variations using minute ventilation sensor, with a good agreement between the respiratory disturbance index and polysomnography results for the diagnosis of severe sleep apnea. The purpose of the study is to examine the diagnostic accuracy of a new pacemaker algorithm for the diagnosis of obstructive sleep apnea in patients presenting with diastolic dysfunction. The investigators also aim to highlight a correlation between plasma aldosterone levels and the severity of sleep apnea, with a reversal effect of ventilation therapy in this specific population.
Study Objectives: Meta-analyses report a high prevalence of moderate to severe sleep apnea of more than 50% in stroke patients, with adherence rates for CPAP therapy of only 30%. The primary objective of this study is to determine whether CPAP adherence in stroke patients with obstructive sleep apnea can be improved by a CPAP training strategy during rehabilitation combined with a telemedicine monitoring system after discharge. The secondary objective is to compare recording quality as well as subjective and objective sleep data of non-attended level III polygraphy, polysomnography and telemetric CPAP data in the management of sleep apnea in stroke. Further the investigators aim to study changes in nocturnal systolic blood pressure due to CPAP therapy with the pulse transit time method. Finally, the investigators intend to study the relationship between CPAP compliance, sleep and medical and neurorehabilition outcome parameters. Design: Single-blind, mono-center, randomized controlled trial on standard CPAP treatment as compared with CPAP treatment with a telemedicine monitoring system in stroke patients with moderate to severe OSA. Setting: Neurorehabilitation center in Vienna, Austria Patients: Adult subacute (1 to 12 months post stroke) stroke patients 18-70 yrs of age) with moderate to severe OSA (apnea hypopnea index (AHI) ≥ 15/hr) determined by non-attended polysomnography (AHI) ≥ 15/hr of sleep) or level III polygraphy (AHI) ≥ 30/hr of out-of-center sleep testing (OCST), who undergo successful CPAP training and titration (goal AHI< 10) at the neurorehabilitation unit. Interventions: Patients will be randomized to either standard care with an autotitrating CPAP device or an autotitrating CPAP device that transmits physiologic information (i.e., adherence, air leak, residual AHI) daily to a website that will be reviewed by their homecare provider. If any problems are identified, the patient will be contacted by his homecare provider by telephone. Neurologists performing sleep and neurological scoring will be blinded to the randomization. Measurements: Recording of the different measuring systems, subjective and objective sleep quality, CPAP adherence after 3 months and 1 year in hours used per night, systolic BP determined by means of a non-linear algorithm and an individual one-point calibration of the pulse transit time obtained with a cuff-based BP measuring system (SOMNOmedics GmbH, Germany) and neurorehabilitation outcome parameters as Barthel Index, Timed Up and Go Test.
This investigation is designed to evaluate the performance (leak and comfort) as well as the participant's overall acceptance of the nasal pillows mask amongst Obstructive Sleep Apnea (OSA) participants. Also to assist in the development process it would be beneficial to get feedback from users on certain aspects of the design. The aim of this investigation is to get feedback on the first impressions (look and feel) from users of nasal pillows PAP therapy. A total number of 15 participants who currently use a nasal pillows mask will be recruited for the trial. Participants from previous NZ trials may be recruited into this trial with their consent. All the participants will be recruited from the Fisher & Paykel Healthcare Database of subjects with OSA (Ethics Reference NTY/08/06/064), Auckland District Health Board (ADHB) and New Zealand Respiratory and Sleep Institute (NZRSI). Participants will undergo an overnight polysomnography session at the Fisher & Paykel Healthcare sleep lab. The participant will use the trial device on their usual Continuous or Auto Positive Airway Pressure (CPAP/APAP) setting and device for the duration of the overnight in-lab study.
Scleroderma is an autoimmune disease with skin manifestations and may have pulmonary involvement. Obstructive sleep apnea (OSA) may also be seen in scleroderma. Less is known regarding the prevalence of OSA in scleroderma and its association with pulmonary involvement.
Test the effect of added a single-use Varnum mouthpiece on pharyngeal collapsibility and obstructive sleep apnea (OSA) severity in patients who identify themselves as mouth breathers. Research indicates that nasal breathing not only may improve sleep apnea but it also increases circulation, blood oxygen, and carbon dioxide levels, slows the breathing rate, and improves overall lung volumes. Thus, the investigators will test whether a single-use Varnum mouthpiece can improve pharyngeal collapsibility and OSA severity in mouth breathers.
To determine the impact, if any the application of oxygen during the apnea period of rapid sequence intubation has on patients being intubated in the emergency department.
Background. Atrial fibrillation is one of the most common complications in the postoperative period of coronary artery bypass grafting (CABG) surgery and usually associated with increased length of hospital stay and higher hospital costs. Among the main mechanisms involved, excessive sympathetic activation, oxidative stress and inflammation are fundamental elements in the pathophysiology of obstructive sleep apnea. Objectives. To evaluate the effects of continuous positive airway pressure (CPAP) in reduction of atrial fibrillation after CABG in patients with obstructive sleep apnea. Methodological procedures: A multicenter randomized controlled study to compare the incidence of atrial fibrillation between the intervention group and the control group, both monitored seven days with Holter.