Cardiac resynchronization therapy (CRT) with biventricular pacing (BVP) is indicated for patients with low ejection fraction and persistent symptoms of heart failure despite medical therapy and a wide QRS-complex, preferably with a left bundle branch block. Unfortunately, up to 40 % receiving CRT do not respond with subjective improvement or improved left ventricular ejection fraction from the treatment. There are few therapeutic alternatives in patients not responding to CRT with BVP, and the potential to improve cardiac function in these patients could make a large difference in terms of life quality and prognosis. His-bundle pacing (HBP) can be a suitable alternative, but is likely not possible in all patients with failed CRT. Furthermore, upgrading to HBP does require a surgical procedure and therefore exposes the patients to risk of complications (e.g. infection of the device). Therefore, early identification of the patients who are likely to benefit from an upgrade to HBP would be beneficial. This study aims to evaluate if patients with failed CRT treatment will benefit from hemodynamic improvement if they are treated with temporary HBP, without opening the device-pocket, and exposing the existing pacemaker-device to a risk of infection. A temporary pacemaker lead and pacing sheath will be used, and placed in the heart via a blood vessel on the right side of neck, using local anaesthesia. Acute effects on the pump function of the heart will be measured during rest and during supine bicycle test (the equivalent of moderate physical activity). Factors associated with a beneficial effect will be evaluated on a group basis. If the individual patient experiences an improvement of cardiac function during the test, he/she will be offered an upgrade to HBP and a replacement of the existing device.


Clinical Trial Description

Primary hypothesis: His-bundle pacing will lead to a better stroke volume at rest compared to biventricular pacing. Primary outcome measure: Stroke-volume (ml) at rest assessed by invasive hemodynamic measurements with the thermodilution method using a Swan-Ganz catheter. Recruitment: Patients will be recruited from the dedicated CRT outpatient clinic at Skane University Hospital. This outpatient clinic evaluates all CRT recipients at 6 months after device implant. If the patient is then a "non-responder" by subjective and objective measures, it is unlikely that there will be any further benefit from the CRT device. Those patients fulfilling the inclusion criteria but not the exclusion criteria will therefore be invited to participate in the study. Written information will be provided to all patients prior to informed consent is signed. Procedure: All patients will undergo a temporary His-bundle stimulation and hemodynamic evaluation. The procedure takes place at the dedicated laboratory for advanced hemodynamic evaluation at Skåne University Hospital in Lund. The first option for vascular access is the right external jugular vein. Under sterile conditions, ultrasound guided venous puncture will be performed, using standard Seldinger technique. A 7F catheter (Medtronic C315) will then be placed over a long guidewire, and used to direct a dedicated pacemaker lead (Medtronic Select Secure 3830) to the His bundle. In case of technical difficulties, a steerable 9F catheter will be used instead (Medtronic C304 deflectable). If HBP is not possible using jugular access, an alternate access via the right femoral vein may be used instead. If the femoral vein is used, only resting measurements will be performed, since it is not possible to thread on the supine bike with a catheter in situ via the femoral vein. In parallel, in a short 8F introducer, a 7F multilumen Swan Ganz catheter will be placed over a long guidewire, and advanced to the left or right pulmonary artery. The catheter will then be wedged in a pulmonary segmental artery to obtain left atrial pressure curves. The pacing lead will be connected to an electrophysiology 12-lead ECG system with capability of pacing and continuous ECG registration of external and intracardiac signals. His bundle potential will be identified probing the correct anatomical area with the electrode, and subsequently the pacing properties of the electrode will be tested. If the pacing properties result in selective (or subsidiary non-selective) his bundle capture, the electrode will be secured in place by 2-3 careful rotations of the entire electrode. The goal is to achieve a stable position with minimal risk of damaging the conduction system by trauma. Since the patients are paced using the CRT device anyway, trauma to the conduction system will not be deleterious, but it may hamper the ability to place a permanent HBP lead at a later stage, if that is indicated. When stable pacing conditions are in place, the stimulation program will be initiated. Depending on randomization results, the intrinsic CRT system or the temporary His-lead will be used for pacing. Pacing and sensing in the right atrium will be achieved using atrial electrodes on the outside of the Swan Ganz catheter. The patients are randomized to wither Biventricular pacing first or HBP first. The pacing program involves both pacing at rest and pacing during sub maximal exercise test (supine bicycle test). Each pacing step is sustained at steady state for at least 2 minutes prior to measurement of intracardiac pressures, cardiac output and stroke volume calculations. After the pacing protocol is finished, the catheters are withdrawn and the site of venopuncture is manually compressed during 5 minutes. The patients are then observed during 2 hours, before discharge and completion of the study. A hemodynamic optimization will be performed regarding device settings for all patients. Patients who have a positive hemodynamic response to HBP, compared to CRT pacing, will at a follow-up stage be offered an upgrade to permanent HBP. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04701112
Study type Interventional
Source Region Skane
Contact
Status Suspended
Phase N/A
Start date September 1, 2021
Completion date February 28, 2026

See also
  Status Clinical Trial Phase
Withdrawn NCT03227393 - The Effect of Yoga on Cardiac Sympathetic Innervation Evaluated by I-123 mIBG N/A
Recruiting NCT04528004 - Mechanistic Studies of Nicotinamide Riboside in Human Heart Failure Early Phase 1
Recruiting NCT04703842 - Modulation of SERCA2a of Intra-myocytic Calcium Trafficking in Heart Failure With Reduced Ejection Fraction Phase 1/Phase 2
Recruiting NCT04522609 - Electrostimulation of Skeletal Muscles in Patients Listed for a Heart Transplant N/A
Completed NCT05475028 - Network Medicine Approaches to Classify Heart Failure With PReserved Ejection Fraction by Signatures of DNA Methylation and Point-of-carE Risk calculaTors (PRESMET)
Not yet recruiting NCT06240403 - Digoxin and Senolysis in Heart Failure and Diabetes Mellitus Phase 2
Not yet recruiting NCT05988749 - Digital Remote Home Monitoring for Heart Failure N/A
Recruiting NCT04950218 - The Psoriasis Echo Study
Completed NCT03305692 - ECG Belt vs. Echocardiographic Optimization of CRT N/A
Recruiting NCT05933083 - MCNAIR Study: coMparative effeCtiveness of iN-person and teleheAlth cardIac Rehabilitation N/A
Enrolling by invitation NCT03903107 - The Fluoroless-CSP Trial Using Electroanatomic Mapping N/A
Withdrawn NCT04872959 - TRANSFORM Heart Failure With Reduced Ejection Fraction N/A
Completed NCT02920918 - Treatment of Diabetes in Patients With Systolic Heart Failure Phase 4
Completed NCT02334891 - Kyoto Congestive Heart Failure Study
Recruiting NCT03553303 - Pharmacodynamic Effects of Sacubitril/Valsartan on Natriuretic Peptides, Angiotensin and Neprilysin Phase 4
Recruiting NCT04083690 - Multi-lead ECG to Effectively Optimize Resynchronization Devices: New CRT Recipients N/A
Recruiting NCT03830957 - Efficacy and Safety of Ivabradine to Reduce Heart Rate Prior to Coronary CT-angiography in Advanced Heart Failure: Comparison With β-Blocker N/A
Recruiting NCT06121323 - Physiological Effects of Lactate in Individuals With Chronic Heart Failure N/A
Completed NCT03351283 - Effect of Sodium Intake on Brain Natriuretic Peptide Levels in Patients With Heart Failure N/A
Recruiting NCT02960685 - Telesonography for Visually Estimating Ejection Fraction N/A