Vital Signs Clinical Trial
Official title:
Vital Signs Data Collection Using "Comestai" Application
The purpose of the study is to verify and validate the parameters collected from mobile devices via the app named "Comestai" and from reference devices. The assessments considered to define comorbidities are included.. Specifically, collection of vital parameters (Blood Pressure, Heart Rate, Respiratory Rate, Oxygen Saturation) through the "Comestai" Application via mobile phones (using photoplethysmographic method) and reference devices such as Withings-Blood Pressure Monitor Connect® (for Blood Pressure), Polar Verity Sense® (for Heart Rate), Masimo-finger sensor® (for Oxygen Saturation, Respiratory Rate), comparing and confirming them. Consent will be sought for the viewing and collection of blood test results that are normally included in evaluations for subjects with overweight and/or obesity and/or diabetes. Estimated time required for each measurement recording: 10-15 minutes per subject Total number of subjects: 3000
Status | Not yet recruiting |
Enrollment | 3000 |
Est. completion date | June 1, 2025 |
Est. primary completion date | December 1, 2024 |
Accepts healthy volunteers | Accepts Healthy Volunteers |
Gender | All |
Age group | 16 Years to 65 Years |
Eligibility | Inclusion Criteria: Prior to enrollment in this study, subjects must meet all the following inclusion criteria: 1. Subject must have the ability to understand and provide written informed consent. 2. Male or Female subject =16 and =65 of age. 3. Subject must be willing and able to comply with study procedures. Exclusion Criteria: Subjects will be excluded from the study if any of the following conditions are present: 1. Subject with compromised circulation, injury, or physical malformation of fingers, hands, ears or forehead/skull or other sensor Region of Interest (ROI) which would limit the ability to test ROI needed for the study. 2. Subject has a tattoo in the optical path which would limit the ability to test ROI needed for the study. 3. Subjects with severe contact allergies to standard adhesives, latex or other materials found in pulse oximetry sensors, respiration monitor electrodes or other medical sensors used for measuring vital signs. 4. Subject with a medical condition which in the opinion of the investigator, does not allow performing the study assessments. 5. Subject unfit to participate in the study to the judgment of the investigator. In addition to the Inclusion/Exclusion criteria, the 70% of target population should include adult subjects with at least one of the following: - Pre-diabetes or diabetes HbA1C 5.7-13% - >30% of subjects with HbA1C 5.7-6.4% - >30% of subjects with HbA1C >6.4% - Hypertension with systolic measurements above 130 mmHg - >40% of subjects with systolic BP >130 mmHg - >20% of subjects with systolic BP >160 mmHg - Total cholesterol: >40% of subjects with >200 mg/dl and/or LDL above 130 mg/dl - Atrial fibrillation 1% - Smokers ~ 20-30% of all subjects in the study Note: the same subject can have more than one of the above medical conditions. It is preferred that subjects will be treatment- naive for the medical condition they suffer from or are not under treatment at the time of participation (e.g. a subject who suffers from hypertension has not started his treatment to lower his blood pressure). |
Country | Name | City | State |
---|---|---|---|
n/a |
Lead Sponsor | Collaborator |
---|---|
Buzzi Children's Hospital |
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Data Collection Storage and Processing-Pulse rate | Collect, verify and validate Pulse rate (beats per minute) in data using the Comestai application and reference devices.
Pulse rate data obtained using the Comestai application and reference data will be stored on Comestai's secured cloud without any subject identifiable information and will only be recognized using the subject identification number provided during screening. The raw data of subjects' vital signs will be locked, encrypted, and can be read only by Study center team. The measurement method utilized by the app is Remote Photoplethysmography (rPPG). No medical decisions will be made based on the data obtained using the Comestai application, the reference devices, and the pre-scheduled blood sample results. |
15 minutes for data collection | |
Primary | Data Collection Storage and Processing-Oxygen saturation | Collect, verify and validate Oxygen saturation (percentage) in data using the Comestai application and reference devices.
Oxygen saturation data obtained using the Comestai application and reference data will be stored on Comestai's secured cloud without any subject identifiable information and will only be recognized using the subject identification number provided during screening. The raw data of subjects' vital signs will be locked, encrypted, and can be read only by Study center team. The measurement method utilized by the app is Remote Photoplethysmography (rPPG). No medical decisions will be made based on the data obtained using the Comestai application, the reference devices, and the pre-scheduled blood sample results. |
15 minutes for data collection | |
Primary | Data Collection Storage and Processing-Respiratory rate | Collect, verify and validate Respiratory rate (breaths per minute) in data using the Comestai application and reference devices.
Respiratory rate data obtained using the Comestai application and reference data will be stored on Comestai's secured cloud without any subject identifiable information and will only be recognized using the subject identification number provided during screening. The raw data of subjects' vital signs will be locked, encrypted, and can be read only by Study center team. The measurement method utilized by the app is Remote Photoplethysmography (rPPG). No medical decisions will be made based on the data obtained using the Comestai application, the reference devices, and the pre-scheduled blood sample results. |
15 minutes for data collection | |
Primary | Data Collection Storage and Processing-Blood pressure | Collect, verify and validate Blood pressure (mmHg) in data using the Comestai application and reference devices.
Blood pressure data obtained using the Comestai application and reference data will be stored on Comestai's secured cloud without any subject identifiable information and will only be recognized using the subject identification number provided during screening. The raw data of subjects' vital signs will be locked, encrypted, and can be read only by Study center team. The measurement method utilized by the app is Remote Photoplethysmography (rPPG). No medical decisions will be made based on the data obtained using the Comestai application, the reference devices, and the pre-scheduled blood sample results. |
15 minutes for data collection | |
Secondary | Data Collection Storage and Processing-Hemoglobin | Collect, verify and validate Hemoglobin level (g/dl) in data using the Comestai application and results of pre-scheduled blood tests
Hemoglobin level data obtained using the Comestai application and results of pre-scheduled blood tests will be stored on Comestai's secured cloud without any subject identifiable information and will only be recognized using the subject identification number provided during screening. The raw data of subjects' vital signs will be locked, encrypted, and can be read only by Study center team. The measurement method utilized by the app is Remote Photoplethysmography (rPPG). No medical decisions will be made based on the data obtained using the Comestai application, the reference devices, and the pre-scheduled blood sample results. |
15 minutes for data collection | |
Secondary | Data Collection Storage and Processing-Hemoglobin glycosylated | Collect, verify and validate Hemoglobin glycosylated level (mmol/mol) in data using the Comestai application and results of pre-scheduled blood tests
Hemoglobin glycosylated level data obtained using the Comestai application and and results of pre-scheduled blood tests will be stored on Comestai's secured cloud without any subject identifiable information and will only be recognized using the subject identification number provided during screening. The raw data of subjects' vital signs will be locked, encrypted, and can be read only by Study center team. The measurement method utilized by the app is Remote Photoplethysmography (rPPG). No medical decisions will be made based on the data obtained using the Comestai application, the reference devices, and the pre-scheduled blood sample results. |
15 minutes for data collection |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05908045 -
Have Physical Therapists Attitudes and Beliefs Towards Vital Assessment Changed Following the COVID-19 Pandemic?
|
||
Enrolling by invitation |
NCT05975658 -
WIReD: Wireless Interstage Remote Device Study
|
||
Completed |
NCT03143062 -
The National Early Warning Score: Preceding Dynamics in the Score for Those Who Suffer an In-hospital Cardiac Arrest
|
||
Completed |
NCT03179267 -
Detection of Deterioration by SNAP40 Versus Standard Monitoring in the ED
|
N/A | |
Not yet recruiting |
NCT05023356 -
Non-contact Vital Signs Monitoring in Anesthesia
|
||
Recruiting |
NCT05970614 -
The Effect of Eye Masks and Earplugs In Intensive Care Unit Patients
|
N/A | |
Completed |
NCT01448161 -
A Machine Learning Approach to Continuous Vital Sign Data Analysis
|
||
Recruiting |
NCT05013411 -
Rethinking Observations in Mental Health
|
||
Completed |
NCT04678050 -
Dexmedetomidine Compared to Ketofol for Sedation in Paediatrics
|
Phase 1 | |
Not yet recruiting |
NCT04976907 -
Peri-operative Mobile Application for Contactless Screening and Vital Signs Measurement
|
||
Completed |
NCT01157832 -
Evaluation of the Acute Effect of Water-Pipe Smoking on the Respiratory System
|
N/A | |
Completed |
NCT04003662 -
Vital Sign Comparison Between Lifelight and Standard of Care - Development
|
||
Recruiting |
NCT05241483 -
Remote Patient Monitoring and Detection of Possible Diseases With Artificial Intelligence Telemedicine System
|
||
Not yet recruiting |
NCT04627766 -
Validation of Continuous Monitoring of Vital Signs in Children With a Connected Patch
|
N/A | |
Completed |
NCT04997694 -
Effect of Preoperative Active Warming and Passive Warming Methods on Perioperative Hypothermia
|
N/A | |
Active, not recruiting |
NCT04935190 -
Comparison of Resting Heart and Respiratory Rate Measurements Acquired by Contactless Radar Sensors, Electrocardiography, and Capnography
|
||
Completed |
NCT04935723 -
The Effects of Reiki on Abdominal Surgery Patients' Anxiety, Fear, Postoperative Pain and Life Findings
|
N/A | |
Completed |
NCT05131620 -
Virtual Reality and Acupressure Applications; Effect on Pain, Anxiety, Vital Signs and Comfort
|
N/A | |
Completed |
NCT02524470 -
Vital Signs Patch Early Feasibility and Usability Study v1.0
|
N/A | |
Not yet recruiting |
NCT06465875 -
The Effect of Book Reading on Comfort, Hope, Anxiety and Vital Signs of Intensive Care Unit Patients
|
N/A |