Clinical Trials Logo

Clinical Trial Summary

Small connected devices monitoring vital signs do not exist in children although they could be very useful to monitor patients once they have left the pediatric intensive care unit (PICU) in order to early identify patients at risk of PICU readmission. The main objective of this study is to assess the accuracy of a connected thoracic patch (VT-Patch) for the continuous monitoring of vital signs in PICU patients. This monitoring device will be used to monitor children in PICU for 8 hours and results will be compared to the standard of care in the unit which is the Philips monitoring system. The investigators will assess the device's accuracy for the monitoring of 4 vital signs (SpO2, heart rate, respiratory rate and temperature) and perform exploratory assessment of three additional parameters (EKG, blood pressure and movement capture). The skin colour of each participant will be categorized based on Fitzpatrick scale and non-invasive spectroscopic method.


Clinical Trial Description

Introduction: Patients readmission to PICU is a major point of concern for physician because, although being a rare event, it has been strongly associated to more morbidity and death. Patients monitoring once they have left the PICU is drastically modified and small connected devices could be an option to early identify patients at risk of PICU readmission. Such devices have been manufactured for the monitoring of adults but they do not exist for children. Main objective: Assess the accuracy of VT-Patch versus standard of care (Philips monitoring system) for the continuous monitoring of oxygen saturation (SpO2) in PICU patients. Secondary objectives: Assess the accuracy of VT-Patch monitoring for 3 additional physiologic parameters (heart rate (HR), respiratory rate (RR) and temperature). Exploratory assessment of blood pressure (BP) monitoring, ECG signal and movement capture. The effect of the skin colour on the vital signs measurements will be investigated as well. Design: Prospective validation study of VT-Patch device for the monitoring of 4 physiologic parameters and exploratory assessment of three additional parameters. Methods: The study will be performed in two successive phases: - Run-in phase: testing the device on 6 children to assess the feasibility of the protocol. - Main study: validation phase of the device on 2 children per age group per skin phototype (based on Fitzpatrick scale) to assess its accuracy. The patients of the run-in phase will be included in the main study if no modification of the protocol is required. 5 physiologic parameters (HR, SpO2, RR, temperature and BP) and ECG will be prospectively recorded during 8 hours with VT-Patch and the regular monitoring system implemented in the unit High-resolution database that will be the Gold standard for evaluation. Participating center: 1 center (St. Justine's Hospital). Perspectives: This validation step of the collected data is necessary to validate that VT-Patch is suitable for pediatric patient monitoring. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04627766
Study type Interventional
Source St. Justine's Hospital
Contact Philippe Jouvet, MD, PhD
Phone 514-345-4931
Email philippe.jouvet@umontreal.ca
Status Not yet recruiting
Phase N/A
Start date March 1, 2024
Completion date September 30, 2025

See also
  Status Clinical Trial Phase
Recruiting NCT05908045 - Have Physical Therapists Attitudes and Beliefs Towards Vital Assessment Changed Following the COVID-19 Pandemic?
Enrolling by invitation NCT05975658 - WIReD: Wireless Interstage Remote Device Study
Completed NCT03143062 - The National Early Warning Score: Preceding Dynamics in the Score for Those Who Suffer an In-hospital Cardiac Arrest
Completed NCT03179267 - Detection of Deterioration by SNAP40 Versus Standard Monitoring in the ED N/A
Not yet recruiting NCT05023356 - Non-contact Vital Signs Monitoring in Anesthesia
Recruiting NCT05970614 - The Effect of Eye Masks and Earplugs In Intensive Care Unit Patients N/A
Completed NCT01448161 - A Machine Learning Approach to Continuous Vital Sign Data Analysis
Recruiting NCT05013411 - Rethinking Observations in Mental Health
Completed NCT04678050 - Dexmedetomidine Compared to Ketofol for Sedation in Paediatrics Phase 1
Not yet recruiting NCT04976907 - Peri-operative Mobile Application for Contactless Screening and Vital Signs Measurement
Completed NCT01157832 - Evaluation of the Acute Effect of Water-Pipe Smoking on the Respiratory System N/A
Completed NCT04003662 - Vital Sign Comparison Between Lifelight and Standard of Care - Development
Recruiting NCT05241483 - Remote Patient Monitoring and Detection of Possible Diseases With Artificial Intelligence Telemedicine System
Completed NCT04997694 - Effect of Preoperative Active Warming and Passive Warming Methods on Perioperative Hypothermia N/A
Active, not recruiting NCT04935190 - Comparison of Resting Heart and Respiratory Rate Measurements Acquired by Contactless Radar Sensors, Electrocardiography, and Capnography
Completed NCT04935723 - The Effects of Reiki on Abdominal Surgery Patients' Anxiety, Fear, Postoperative Pain and Life Findings N/A
Completed NCT05131620 - Virtual Reality and Acupressure Applications; Effect on Pain, Anxiety, Vital Signs and Comfort N/A
Completed NCT02524470 - Vital Signs Patch Early Feasibility and Usability Study v1.0 N/A
Completed NCT05027659 - The Effects of Virtual Reality Glasses on Vital Signs and Anxiety in Patients Undergoing Colonoscopy N/A
Not yet recruiting NCT05451875 - Comparison of Continuous Non-invasive All Vital Signs Monitoring Devices With Invasive Gold Standard for Children