NCT ID: NCT03951064 Terminated - Respiratory Failure Clinical Trials

Providing Optimal PEEP During Mechanical Ventilation for Obese Patients Using Esophageal Balloon

PROP OPEN
Start date: March 31, 2021
Phase: N/A
Study type: Interventional

This is a research study to determine if identifying an optimal level of positive end-expiratory pressure (PEEP) targeted specifically to individualized patient characteristics will shorten the time on the ventilator. Participants will have catheter placed through the nose into the esophagus to measure the pressure inside the chest. This catheter will remain until the patient is freed from the ventilator. Participants will be randomized to usual care or to have the level of PEEP determined by the esophageal balloon pressure readings. The total time spent on the ventilator will be recorded.

NCT ID: NCT03525691 Terminated - ARDS, Human Clinical Trials

Enhanced Lung Protective Ventilation With ECCO2R During ARDS

PROVE
Start date: May 23, 2018
Phase: N/A
Study type: Interventional

Acute Respiratory Distress Syndrome (ARDS) is associated with a mortality rate of 30 - 45 % and required invasive mechanical ventilation (MV) in almost 85 % of patients[1]. During controlled MV, driving pressure (i.e., the difference between end-inspiratory and end-expiratory airway pressure) depends of both tidal volume and respiratory system compliance. Either excessive tidal volume or reduced lung aeration may increase the driving pressure. ARDS patients receiving tidal volume of 6 ml/kg predicted body weight (PBW) and having a day-1 driving pressure ≥ 14 cmH2O have an increased risk of death in the hospital[2]. Seemly, in the LUNG SAFE observational cohort, ARDS patients having a day-1 driving pressure < 11 cmH2O had the lowest risk of death in the hospital[1]. Hence, driving pressure acts as a major contributor of mortality in ARDS, and probably reflects excessive regional lung distension resulting in pro-inflammatory and fibrotic biological processes. Whether decreasing the driving pressure by an intervention change mortality remains an hypothesis; but one of means is to decrease the tidal volume from 6 to 4 ml/ kg predicted body weight (PBW). However, this strategy promotes hypercarbia, at constant respiratory rate, by decreasing the alveolar ventilation. In this setting, implementing an extracorporeal CO2 removal (ECCO2R) therapy prevents from hypercarbia. A number of low-flow ECCO2R devices are now available and some of those use renal replacement therapy (RRT) platform. The investigators previously reported that combining a membrane oxygenator (0.65 m²) within a hemofiltration circuit provides efficacious low flow ECCO2R and blood purification in patients presenting with both ARDS and Acute Kidney injury[3]. This study aims to investigate the efficacy of an original ECCO2R system combining a 0.67 m² membrane oxygenator (Lilliput 2, SORIN) inserted within a specific circuit (HP-X, BAXTER) and mounted on a RRT monitor (PrismafleX, BAXTER). Such a therapy only aims to provide decarboxylation but not blood purification and has the huge advantage to be potentially implemented in most ICUs without requiring a specific ECCO2R device. The study will consist in three periods: - The first period will address the efficacy of this original ECCO2R system at tidal volume of 6 and 4 ml/kg PBW using an off-on-off design. - The second part will investigate the effect of varying the sweep gas flow (0-2-4-6-8-10 l/min) and the mixture of the sweep gas (Air/O2) on the CO2 removal rate. - The third part will compare three ventilatory strategies applied in a crossover design: 1. Minimal distension: Tidal volume 4 ml/kg PBW and positive end-expiratory pressure (PEEP) based on the ARDSNet PEEP/FiO2 table (ARMA). 2. Maximal recruitment: 4 ml/kg PBW and PEEP adjusted to maintain a plateau pressure between 23 - 25 cmH2O. 3. Standard: Tidal volume 6 ml/kg and PEEP based on the ARDSNet PEEP/FiO2 table (ARMA).

NCT ID: NCT01522599 Terminated - Clinical trials for Acute Respiratory Distress Syndrome

Flow-flow ECCO2-R and 4 ml/kg Tidal Volume vs. 6 ml/kg Tidal Volume to Enhance Protection From VILI in Acute Lung Injury

ELP
Start date: April 2012
Phase: Phase 3
Study type: Interventional

The main objective of this randomized multicenter clinical trial is to test the hypothesis that further reduction of VT to 4mL/kg may enhance lung protection in patients with ARDS as compared to the conventional "ARDS-Net" ventilation. Control of PaCO2 in the ~4 ml/kg arm would be accomplished by LFPPV- ECCO2-R.