Aortic Valve Stenosis Clinical Trial
Official title:
Diagnostic Impact of Low-dose Dobutamine Echocardiography in Low-flow Low-gradient Aortic Stenosis
When aortic valve-area is <1.0cm2 and transvalvular mean-gradient is >40mmHg, the diagnosis of severe aortic stenosis (AS) is straightforward. However, some patients present with an apparently reduced valve-area, despite transvalvular-gradient <40mmHg; Low-flow, low-gradient aortic stenosis (LFLG AS). When a patient with LFLG AS also presents with LVEF <50%, guidelines recommends performing a Low-Dose Dobutamine-echocardiography (LDDE) to confirm true-severe AS. However, nearly 30% of patients with LFLG AS do not show an adequate respond to Dobutamine. More commonly, patients present with the combination of LFLG AS, despite LVEF≥50%. In this group of patients the use of LDDE remains undisclosed. The purpose of this study is to examine the safety and diagnostic usefulness of LDDE in patients with LFLG AS with LVEF≥50%. Furthermore we will examine factors associated with inadequate response to LDDE. 150 symptomatic and/or asymptomatic patients with LFLG and LVEF≥50% and a control group with LVEF<50% will be enrolled at the Department of Cardiology, OUH. Patients will undergo clinical evaluation including LDDE, blood analyses, CT-scan and cardiac Mri. Only a limited number of studies examine the possible use of LDDE in patients with LFLG AS and LVEF≥50% and no study has been performed documenting the safety and feasibility.
n/a
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03186339 -
Validation of the "TASQ" in Patients Undergoing SAVR or TF-TAVI
|
||
Recruiting |
NCT03549559 -
Imaging Histone Deacetylase in the Heart
|
N/A | |
Terminated |
NCT02854319 -
REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System
|
N/A | |
Recruiting |
NCT05601453 -
The ReTAVI Prospective Observational Registry
|
||
Withdrawn |
NCT05481814 -
CPX in Paradoxical Low Flow Aortic Stenosis
|
||
Completed |
NCT02241109 -
Predicting Aortic Stenosis Progression by Measuring Serum Calcification Propensity
|
N/A | |
Completed |
NCT01700439 -
Surgical Treatment of Aortic Stenosis With a Next Generation, Rapid Deployment Surgical Aortic Valve
|
N/A | |
Recruiting |
NCT04429035 -
SLOW-Slower Progress of caLcificatiOn With Vitamin K2
|
N/A | |
Completed |
NCT04103931 -
Impact of a Patient Decision Aid for Treatment of Aortic Stenosis
|
N/A | |
Completed |
NCT03950440 -
Assessing the Incidence of Postoperative Delirium Following Aortic Valve Replacement
|
||
Active, not recruiting |
NCT02661451 -
Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD)
|
N/A | |
Completed |
NCT02847546 -
Evaluation of the BARD® True™ Flow Valvuloplasty Perfusion Catheter for Aortic Valve Dilatation
|
N/A | |
Completed |
NCT02792452 -
Clinical Value of Stress Echocardiography in Moderate Aortic Stenosis
|
||
Completed |
NCT02758964 -
Evaluation of Cerebral Thrombembolism After TAVR
|
||
Not yet recruiting |
NCT02541877 -
Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve
|
Phase 3 | |
Not yet recruiting |
NCT02536703 -
Safety and Efficacy of Lotus Valve For TAVI In Patients With Severe Aortic Stenosis In Chinese Population
|
Phase 3 | |
Completed |
NCT02249000 -
BIOVALVE - I / II Clincial Investigation
|
N/A | |
Not yet recruiting |
NCT02221921 -
Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI
|
N/A | |
Active, not recruiting |
NCT02080299 -
Protection by Remote Ischemic Preconditioning During Transcatheter Aortic Valve Implantation
|
Phase 2 | |
Terminated |
NCT01939678 -
Characterization and Role of Mutations in Sodium-phosphate Cotransporters in Patients With Calcific Aortic Valve Disease
|