Valve Heart Disease Clinical Trial
Official title:
Balloon Expandable vs. Self Expanding Transcatheter Valve for Degenerated Bioprosthesis. THE BASELINE TRIAL.
Transcatheter aortic valve implantation (TAVI) serves a growing spectrum of patients with symptomatic severe aortic stenosis (AS). Approximately 80% of surgical aortic valve replacements is performed using a bioprosthesis1. Durability of surgical bioprostheses varies based on the patient's age at the moment of implantation, type and size etc2. TAVI has become the preferred treatment for degenerated aortic bioprostheses in elderly patients3. The median time since index surgical aortic valve replacement (SAVR) and for bioprosthetic valve degeneration is typically 8 - 10 years4-6. TAVI in this setting has proven to have equally favorable results as in native aortic valves7. Balloon expandable8 and self-expanding9 transcatheter heart valves (THV) can be used in a degenerated bioprosthesis and each have specific assets and limitations. TAVI in a failed bioprosthesis can cause coronary obstruction, THV migration, paravalvular leakage and prosthesis patient mismatch. The SAPIEN-3 / Ultra and EVOLUT R/Pro are the 2 most commonly used THV platforms in contemporary clinical practice including treatment of failing surgical aortic bioprostheses. Objective: To compare TAVI with EVOLUT R/Pro vs. SAPIEN-3 / Ultra in terms of device success. Study design: International multi-center randomized study with 1:1 randomization to TAVI with SAPIEN-3 / Ultra or Evolut R/Pro. Study population: 440 patients with a failing surgical aortic bioprosthesis (aortic stenosis with or without aortic regurgitation) and selected for transfemoral TAVI by heart-team consensus. Investigational intervention: Transfemoral TAVI with SAPIEN-3 / Ultra or Evolut R/PRO Main study parameters/endpoints: 1. Primary endpoint is device success at 30 days Defined by - Absence of procedural mortality AND - Correct positioning of a single prosthetic heart valve into the proper anatomical location AND - Intended performance of the prosthetic heart valve (no severe prosthesis- patient mismatch and mean aortic valve gradient < 20 mmHg or peak velocity < 3 m/s, AND no moderate or severe prosthetic valve regurgitation). Severe prosthesis patient mismatch is defined by effective orifice area (EOAi) ≤0.65 cm2/m2 2. Safety endpoint at 1 year defined by the composite of all-cause death, disabling stroke, rehospitalization for heart failure or valve related problems.
n/a
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT06066970 -
Cardiac Biomarkers for the Quantification of Myocardial Damage After Cardiac Surgery
|
||
Recruiting |
NCT05079672 -
Efficacy and Safety of Dexmedetomidine in the Analgesic Prophylaxis , in Patients Undergoing Cardiovascular Surgery
|
Phase 4 | |
Completed |
NCT03347851 -
Post-surgical Aortic Hemodynamics After Aortic Valve Replacement
|
||
Active, not recruiting |
NCT03539458 -
Feasibility Study of the Tendyne Mitral Valve System in Mitral Annular Calcification
|
N/A | |
Completed |
NCT04328090 -
Evaluation of the Potential Impact of Computerized Antimicrobial Stewardship
|
N/A | |
Recruiting |
NCT04359030 -
Freestyle-Perimount Calcification Comparison
|
||
Completed |
NCT04958668 -
Prospective Evaluation of Volatile Sedation After Heart Valve Surgery
|
N/A | |
Completed |
NCT04598360 -
Release of Epoxyeicosatrienoic Acids From Erythrocytes During the Use of Extracorporeal Procedures (Heart-lung Machine)
|
N/A | |
Not yet recruiting |
NCT04118621 -
Role of Chest Ultrasound in Detection of Post-operative Pulmonary Complications After Cardiothoracic Surgery
|
||
Recruiting |
NCT06387446 -
Allogeneic Valve Transplantation
|
N/A | |
Completed |
NCT05804500 -
RecoveryPlus Telerehab Platform Pilot Study
|
N/A | |
Recruiting |
NCT03885180 -
Randomized Evaluation of D-dimer Guiding dUration of Oral antiCoagulation thErapy
|
N/A | |
Completed |
NCT06154018 -
Heparin Reversal With Two Different Protamine Ratios After Cardiopulmonary By-pass.
|
N/A | |
Recruiting |
NCT06041308 -
Bioprothetic Valve Versus Mechanical Valve of Bioprothetic Valve Versus Mechanical Valve
|
||
Suspended |
NCT01571791 -
Perioperative Ketorolac-lidocaine in the Patients With Valvular Heart Diseases During Cesarean Delivery
|
Phase 2 | |
Completed |
NCT06261788 -
Efficacy and Safety of the Sync-AV II Temporary Cardiac Pacing Catheter
|
N/A | |
Completed |
NCT06079008 -
The Association of Cardiac Valve Calcification and 1-year Mortality After Lower-extremity Amputation in Diabetic Patients
|
||
Completed |
NCT04372654 -
Pilot Study Evaluating the Safety of Electroducer Sleeve Medical Device for Temporary Cardiac Stimulation During Percutaneous Cardiovascular Interventions, in All Kind of Patients
|
N/A | |
Active, not recruiting |
NCT03661398 -
Caisson Transcatheter Mitral Valve Replacement (TMVR)
|
N/A | |
Recruiting |
NCT03595423 -
SPAnish Aortic VALVE Multicentric Study
|