Upper Gastrointestinal Disease, Duodenal or Gastric Ulcer. Clinical Trial
Official title:
Transnasal and Conventional Oral Diagnostic Gastroscopy. A Prospective Randomised Study.
Two groups of patients were randomised into two groups of either transnasal gastroscopy or conventional type gastroscopy (n=98). The aim of the study was to evaluate the cardiorespiratory effects and sideeffects of the two methods, and to evaluate the technical features of the transnasal endoscope.
Introduction Esophagogastroduodenoscopy is the gold standard investigation for upper
gastrointestinal disorders. To make the procedure safer and more comfortable, thinner
endoscopes for conventional oral or for transnasal intubation have been designed. Several
trials have been conducted suggesting greater patient tolerance with the thinner scope. At
the same time scope features have improved and are increasingly compatible with the standard
endoscope. This prospective, randomised study was conducted to evaluate the cardiopulmonary
effects, the patient tolerance, and endoscopist evaluation comparing thin transnasal with
conventional transoral endoscopy.
Patients and Methods Outpatients referred to diagnostic, upper gastrointestinal endoscopy
were included consecutively after written informed consent. Inclusion criteria were age over
18 years, Danish-language, no history of disease in the nasal cavity and intended diagnostic
endoscopy. Ninety-eight patients were included and randomised to either conventional oral
gastroscopy (OG) or transnasal gastroscopy (TG).The patients were randomized by
consecutively numbered envelopes.
The patients answered a questionnaire clarifying their previous experience of gastroscopy,
and if relevant, the discomfort of previous examination and their anxiety for the actual
examination on a visual analogue scale (VAS scale). A post endoscopy questionnaire evaluated
discomfort during the examination in general, during introduction of the endoscope and for
the rest of the examination (VAS scale). The following parameters were assessed by answering
yes or no; gagging, choking, pain from the nose, throat and the stomach. The patients stated
whether the degree of discomfort had been greater, lesser or as expected compared to
previous endoscopy and whether they in a future gastroscopy would prefer sedation, and
finally they stated their preference for a future procedure (OG/TG).
TG were carried out using Olympus Videoscope GIF-N230 (Olympus Optical Ltd., Tokyo, Japan)
with an outer diameter of 6 mm and working length of 925 mm (first 15 patients); and later
Olympus Videoscope GIF-XP160 (33 patients) with an outer diameter of 5.9 mm, and a working
length of 1030 mm. OG were carried out using Olympus Videoscope GIF-Q160 with an outer
diameter of 9.5 mm and a working length of 1030 mm.
All patients received topical anaesthesia; before TG xylocain gel were inhaled into each
nostril and before OG xylocain spray (10 mg/dose), 4 doses were spayed into the pharyngeal
cavity. Intravenous sedation using midazolam were used only if specifically requested by the
patient. The patients were positioned in the left lateral recumbent position during the
procedures. Endoscopies were performed by experienced endoscopists.
Arterial oxygen saturation (SpO2 ) and heart rate (HR) were measured by a pulse oximeter
(Nellcor Symphony N-3000, Nellcor Puritan Bennet Inc., Pleasanton, CA) twice with an
interval of one minute before the procedure; twice during the procedure (one and three
minutes after intubation) and finally one and two minutes after extubation. The minimum SpO2
and maximum HR were noted as was the duration of the procedure. Biopsies were taken when
indicated, and the qualities of the biopsies were assessed. Adverse effects during the
endoscopies were noted; e.g. epistaxis.
After the endoscopy, the endoscopists answered a questionnaire evaluating the following
parameters using a VAS score: intubation, ability to aspirate gastric contents,
visualization of the esophagus, the stomach, the bulb and the second part of duodenum. The
presence of chromatic aberrations (after flushing and aspiration), were also assessed. It
was noted whether the length of the scope was sufficient, and also in case of TG, the
presence of uni- or bi-lateral stenosis of the nasal cavity and looping in esophagus. If TG
could not be carried out, the reasons were noted.
Finally, the endoscopists assessed their total subjective evaluation of the endoscopy on a
one-to-six scale (one: unacceptable, six: perfect).
;
Allocation: Random Sample, Observational Model: Natural History, Time Perspective: Longitudinal