Type 1 Diabetes Clinical Trial
Official title:
Effects of the Menstrual Cycle on Blood Glucose Changes During Exercise in Women With Type 1 Diabetes Using Oral Contraceptives
Female participants with type 1 diabetes using oral contraceptives will be asked to wear a continuous glucose monitor for at least three days on two separate occasions (once during the last week of active pills and once during the no pill/placebo pill phase of the menstrual cycle). An exercise session (45 minutes of aerobic exercise at 60% VO2peak on a cycle ergometer) will take place at 5 pm on the second day of glucose monitoring.
Pre-test measures: Interested participants will be invited to the Physical Activity and Diabetes Laboratory on the main campus of the University of Alberta. They will be asked questions related to their menstrual cycle, physical activity levels and medication. Blood pressure will also be measured to assess their eligibility. Where participants are eligible, anthropometric characteristics will be measured using standard protocols. A blood sample will be drawn for assessment of HbA1c. Participants will perform an incremental treadmill test to volitional exhaustion. Indirect calorimetry will be used to assess oxygen consumption and carbon dioxide production to determine the participant's aerobic capacity. Testing sessions: Participants will perform two testing sessions separated by at least 5 days. One session will take place during the last week of active pill consumption of monophasic hormonal contraceptives. The second session will take place during the placebo pill consumption phase (i.e. menses). Participants will be asked to arrive at the lab at around 4:00 pm for both sessions, which will be randomly assigned. During the sessions, participants will be asked to perform 45 minutes of aerobic exercise on an ergonomic cycle ergometer at 60% of the participant's pre-determined aerobic capacity. Blood samples will be drawn at baseline, at the end of exercise, and an hour post-exercise via an IV catheter. Participants will be asked to match their daily food and insulin intake as closely as possible from one testing session to the next for the day before, day of and day after the testing session. They will also be asked to avoid strenuous exercise and alcohol intake. A continuous glucose monitor (CGM) sensor will be subcutaneously inserted by one of the investigators (trained by a group from the CGM manufacturer) into the anterior abdominal area of the participant in the morning of the day prior to each testing session. The participant will wear the CGM for at least 24 hours before the exercise session, and at least 24 hours after the exercise session. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05653518 -
Artificial Pancreas Technology to Reduce Glycemic Variability and Improve Cardiovascular Health in Type 1 Diabetes
|
N/A | |
Enrolling by invitation |
NCT05515939 -
Evaluating the InPen in Pediatric Type 1 Diabetes
|
||
Completed |
NCT05109520 -
Evaluation of Glycemic Control and Quality of Life in Adults With Type 1 Diabetes During Continuous Glucose Monitoring When Switching to Insulin Glargine 300 U/mL
|
||
Recruiting |
NCT04016987 -
Automated Structured Education Based on an App and AI in Chinese Patients With Type 1 Diabetes
|
N/A | |
Active, not recruiting |
NCT04190368 -
Team Clinic: Virtual Expansion of an Innovative Multi-Disciplinary Care Model for Adolescents and Young Adults With Type 1 Diabetes
|
N/A | |
Recruiting |
NCT05413005 -
Efficacy of Extracorporeal Photopheresis (ECP) in the Treatment of Type 1 Diabetes Mellitus
|
Early Phase 1 | |
Active, not recruiting |
NCT04668612 -
Dual-wave Boluses in Children With Type 1 Diabetes Insulin Boluses in Children With Type 1 Diabetes
|
N/A | |
Completed |
NCT02837094 -
Enhanced Epidermal Antigen Specific Immunotherapy Trial -1
|
Phase 1 | |
Recruiting |
NCT05414409 -
The Gut Microbiome in Type 1 Diabetes and Mechanism of Metformin Action
|
Phase 2 | |
Recruiting |
NCT05670366 -
The Integration of Physical Activity Into the Clinical Decision Process of People With Type 1 Diabetes
|
N/A | |
Active, not recruiting |
NCT05418699 -
Real-life Data From Diabetic Patients on Closed-loop Pumps
|
||
Completed |
NCT04084171 -
Safety of Artificial Pancreas Therapy in Preschoolers, Age 2-6
|
N/A | |
Recruiting |
NCT06144554 -
Post Market Registry for the Omnipod 5 System in Children and Adults With Type 1 Diabetes
|
||
Recruiting |
NCT05379686 -
Low-Dose Glucagon and Advanced Hybrid Closed-Loop System for Prevention of Exercise-Induced Hypoglycaemia in People With Type 1 Diabetes
|
N/A | |
Recruiting |
NCT05153070 -
Ciclosporin Followed by Low-dose IL-2 in Patients With Recently Diagnosed Type 1 Diabetes
|
Phase 2 | |
Completed |
NCT05281614 -
Immune Effects of Vedolizumab With or Without Anti-TNF Pre-treatment in T1D
|
Early Phase 1 | |
Withdrawn |
NCT04259775 -
Guided User-initiated Insulin Dose Enhancements (GUIDE) to Improve Outcomes for Youth With Type 1 Diabetes
|
N/A | |
Active, not recruiting |
NCT01600924 -
Study on the Assessment of Determinants of Muscle and Bone Strength Abnormalities in Diabetes
|
||
Completed |
NCT02750527 -
Pediatric Population Screening for Type 1 Diabetes and Familial Hypercholesterolemia in Lower Saxony, Germany
|
||
Completed |
NCT02855307 -
Closed-loop Control of Glucose Levels (Artificial Pancreas) During Postprandial Exercise in Adults With Type 1 Diabetes
|
Phase 2 |