Clinical Trials Logo

Clinical Trial Summary

The main objective of this study is to determine whether home use of fully closed-loop glucose control applying ultra-rapid Lispro insulin is superior to standard insulin pump therapy with continuous glucose monitoring (CGM) in adults with type 1 diabetes on insulin pump therapy with sub-optimal glycaemic control (HbA1c ≥ 8.0%). This is an open-label, single centre, randomised, crossover design study, involving a run-in period followed by two study periods during which glucose levels will be controlled either by an automated closed-loop system using ultra-rapid Lispro insulin or by participants usual insulin pump therapy with continuous glucose monitoring in random order. A total of up to 30 adults (aiming for 24 completed participants) with T1D on insulin pump therapy will be recruited through diabetes clinics and other established methods. Participants who drop out of the study within the first 4 weeks of the first intervention arm will be replaced. Participants will receive appropriate training in the safe use of the closed-loop devices. Participants will have access to the study team during the home study phase with 24/7 telephone support. The primary outcome is time spent in target range between 3.9 and 10.0 mmol/L as recorded by CGM over the 8 week period. Secondary outcomes are HbA1c, time spent with glucose levels above and below target as recorded by CGM, and other CGM-based metrics in addition to insulin requirements. Safety evaluation comprises severe hypoglycaemic episodes, diabetic ketoacidosis (DKA) events and other adverse and serious adverse events.


Clinical Trial Description

Purpose of the clinical trial: To determine whether home use of fully closed-loop applying ultra-rapid Lispro insulin is superior to insulin pump therapy with continuous glucose monitoring (CGM). Study objective: The study objective is to compare home use of fully closed-loop glucose control applying ultra-rapid Lispro insulin with standard insulin pump therapy with CGM. 1. EFFICACY: The objective is to assess the efficacy of fully closed-loop glucose control applying ultra-rapid Lispro insulin in maintaining CGM glucose levels within the target range from 3.9 to 10.0 mmol/l, as compared to standard insulin pump therapy combined with CGM. 2. SAFETY: The objective is to evaluate the safety of fully closed-loop glucose control in terms of episodes of severe hypoglycaemia, hyperglycaemia and other adverse events and adverse device effects. 3. UTILITY: The objective is to determine the percentage of time when closed-loop was operational, and usability and acceptance of the closed-loop system. Participating clinical centres: Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge Sample Size: 24 adults completing the study. Up to 30 participants will be recruited to allow for dropouts. Maximum duration of study for a participant: 20 weeks (5 months) Recruitment The participants will be recruited through the adult diabetes outpatient clinics or other established methods. Consent: Participants will be asked to provide written informed consent. Baseline Assessment: Eligible participants will undergo a baseline evaluation including a blood sample for the measurement of HbA1c, renal, liver functions, full blood count, thyroid functions and coeliac antibody screen (if not done in the previous 3 months). Urine pregnancy test will be done in females of child bearing age. Human factor questionnaires will be administered. Run-in Period During the 2-3 week run-in period, participants will use their own insulin pump and wear a masked CGM system. At the end of the run-in period, for compliance, at least 10 days of CGM data need to be recorded. CGM data during the run-in period will be used to assess baseline glucose control before the start of the first home study phase. Randomisation: Eligible participants will be randomised using randomisation software to the use of closed-loop glucose control or to standard pump therapy with CGM. There will be no washout period between the two intervention periods. Automated closed-loop: Training on the use of closed-loop will be provided by the research team during a 2 to 3 hour session in an outpatient setting (clinical research facility) or may be done remotely. Competency on the use of study insulin pump, study CGM and closed-loop system will be evaluated using a competency assessment tool developed by the research team. Further training may be delivered as required. Participants will be advised to use the closed-loop system with ultra-rapid Lispro insulin for next 8 weeks. Conventional insulin pump therapy with CGM: Participants will use their own insulin pump and study CGM. Training on the use of real-time CGM and how to interpret real-time will be provided. Participants will use standard insulin pump therapy, with their usual insulin, and real-time CGM for the next 8 weeks. Cross-over Assessment: At the end of the first intervention period, a blood sample for the measurement of HbA1c will be taken and human factor questionnaires will be administered. End of study assessments: A blood sample will be taken for measurement of HbA1c and human factor questionnaires will be administered. Study devices will be returned and participants will resume usual care. Procedures for safety monitoring during trial: Standard operating procedures for monitoring and reporting of all adverse events and adverse device events will be in place, including serious adverse events (SAE), serious adverse device effects (SADE) and specific adverse events (AE) such as severe hypoglycaemia. A data monitoring and ethics committee (DMEC) will be informed of all serious adverse events and any unanticipated adverse device/method effects that occur during the study and will review compiled adverse event data at periodic intervals. Criteria for withdrawal of patients on safety grounds: A participant may terminate participation in the study at any time without necessarily giving a reason and without any personal disadvantage. An investigator can stop the participation of a subject after consideration of the benefit/risk ratio. Possible reasons are: - Serious adverse events - Significant protocol violation or non-compliance - Failure to satisfy competency assessment - Decision by the investigator, or the sponsor, that termination is in the participant's best medical interest - Pregnancy, planned pregnancy, or breast feeding - Allergic reaction to insulin - Technical grounds (e.g. participant relocates) ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04977908
Study type Interventional
Source University of Cambridge
Contact
Status Completed
Phase N/A
Start date August 31, 2021
Completion date May 31, 2023

See also
  Status Clinical Trial Phase
Recruiting NCT05653518 - Artificial Pancreas Technology to Reduce Glycemic Variability and Improve Cardiovascular Health in Type 1 Diabetes N/A
Enrolling by invitation NCT05515939 - Evaluating the InPen in Pediatric Type 1 Diabetes
Completed NCT05109520 - Evaluation of Glycemic Control and Quality of Life in Adults With Type 1 Diabetes During Continuous Glucose Monitoring When Switching to Insulin Glargine 300 U/mL
Recruiting NCT04016987 - Automated Structured Education Based on an App and AI in Chinese Patients With Type 1 Diabetes N/A
Active, not recruiting NCT04190368 - Team Clinic: Virtual Expansion of an Innovative Multi-Disciplinary Care Model for Adolescents and Young Adults With Type 1 Diabetes N/A
Recruiting NCT05413005 - Efficacy of Extracorporeal Photopheresis (ECP) in the Treatment of Type 1 Diabetes Mellitus Early Phase 1
Active, not recruiting NCT04668612 - Dual-wave Boluses in Children With Type 1 Diabetes Insulin Boluses in Children With Type 1 Diabetes N/A
Completed NCT02837094 - Enhanced Epidermal Antigen Specific Immunotherapy Trial -1 Phase 1
Recruiting NCT05414409 - The Gut Microbiome in Type 1 Diabetes and Mechanism of Metformin Action Phase 2
Recruiting NCT05670366 - The Integration of Physical Activity Into the Clinical Decision Process of People With Type 1 Diabetes N/A
Active, not recruiting NCT05418699 - Real-life Data From Diabetic Patients on Closed-loop Pumps
Completed NCT04084171 - Safety of Artificial Pancreas Therapy in Preschoolers, Age 2-6 N/A
Recruiting NCT06144554 - Post Market Registry for the Omnipod 5 System in Children and Adults With Type 1 Diabetes
Recruiting NCT05153070 - Ciclosporin Followed by Low-dose IL-2 in Patients With Recently Diagnosed Type 1 Diabetes Phase 2
Recruiting NCT05379686 - Low-Dose Glucagon and Advanced Hybrid Closed-Loop System for Prevention of Exercise-Induced Hypoglycaemia in People With Type 1 Diabetes N/A
Completed NCT05281614 - Immune Effects of Vedolizumab With or Without Anti-TNF Pre-treatment in T1D Early Phase 1
Withdrawn NCT04259775 - Guided User-initiated Insulin Dose Enhancements (GUIDE) to Improve Outcomes for Youth With Type 1 Diabetes N/A
Active, not recruiting NCT01600924 - Study on the Assessment of Determinants of Muscle and Bone Strength Abnormalities in Diabetes
Completed NCT02855307 - Closed-loop Control of Glucose Levels (Artificial Pancreas) During Postprandial Exercise in Adults With Type 1 Diabetes Phase 2
Completed NCT02750527 - Pediatric Population Screening for Type 1 Diabetes and Familial Hypercholesterolemia in Lower Saxony, Germany