Type 1 Diabetes Clinical Trial
— WSTOfficial title:
Web-Based Simulation Tool For Self-Management Support In Type 1 Diabetes Mellitus
Verified date | February 2023 |
Source | University of Virginia |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
This project focuses on embedding the participants' own diabetes data into state-of-the-art technology platforms to constitute a novel educational simulation interface for decision-support in Type 1 Diabetes (T1D) - the Web-based Simulation Tool (WST).
Status | Completed |
Enrollment | 18 |
Est. completion date | February 22, 2021 |
Est. primary completion date | February 22, 2021 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 21 Years to 65 Years |
Eligibility | Inclusion Criteria: - Age =21 and =65 years old at time of consent. - Clinical diagnosis, based on investigator assessment, of T1D for at least one year. - Using insulin for at least 1 year prior to study enrollment. - Using an insulin pump for at least 6 months prior to study enrollment. - Currently using a CGM for at least 6 months. - Willingness to use a Dexcom G6 CGM during the study; a study Dexcom CGM will be provided if needed. - Current user of the Tandem t:slim X2 insulin pump. - Willingness to switch to lispro (Humalog) or aspart (Novolog) if not using already, and to use no other insulin besides lispro (Humalog) or aspart (Novolog) during the study. - Total daily insulin (TDI) dose at least 10 U/day. - HbA1c =9.0% at screening; if HbA1c <6.0%, then TDI must be = 0.5 U/kg. - Having access to internet (Wi-Fi or 3G, 4G, 5G, or similar). - Willingness to interact with a computer program. - An understanding of and willingness to follow the protocol and sign the informed consent form (ICF). Exclusion Criteria: - Participants who are not able to read and complete questionnaires on the computer or interact with a program for which they will be trained because of language, reading, or cognitive issues. - Severe hypoglycemia resulting in seizure or loss of consciousness in the 12 months prior to enrollment. - History of a seizure disorder (except hypoglycemic seizure), unless written clearance is received from a neurologist and not currently on a seizure medication. - Pregnancy, breast-feeding, or intention of becoming pregnant over time of study procedures. - If female and sexually active, must agree to use a form of contraception to prevent pregnancy while a participant in the study. A negative urine pregnancy test will be required for all premenopausal women who are not surgically sterile. Subjects who become pregnant will be discontinued from the study. - A known medical condition that in the judgment of the investigator might interfere with the completion of the study.* - Abuse of alcohol or recreational drugs. - Infectious process not anticipated to resolve prior to study procedures (e.g. meningitis, pneumonia, osteomyelitis, etc). - Uncontrolled arterial hypertension (resting diastolic blood pressure >90 mmHg and/or systolic blood pressure >160 mmHg). - A recent injury to body or limb, muscular disorder, use of any medication, any carcinogenic disease, or other significant medical disorder if that injury, medication or disease in the judgment of the investigator will affect the completion of the protocol. - Current use of the following drugs and supplements: - Any drug other than insulin to treat diabetes. - Any other medication that according to the investigator's criteria is a contraindication for the subject's participation. - Note: The software implementation, in the current development status, is designed to interact with subjects with T1D that only use insulin for diabetes treatment and do not present any comorbidity related to diabetes. |
Country | Name | City | State |
---|---|---|---|
United States | University of Virginia - Center for Diabetes Technology | Charlottesville | Virginia |
Lead Sponsor | Collaborator |
---|---|
University of Virginia | Juvenile Diabetes Research Foundation, Tandem Diabetes Care, Inc. |
United States,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Other | Potential Correlation Between System Use and Changes in the Percentage of Time Spent in 70-180 mg/dL Between First Week (Observation) and Following 4 Weeks (Intervention) | The percentage of time spent in 70-180 mg/dL (time in range, TIR) is computed per participant on a weekly basis (1 week of observation, 4 weeks of intervention) using glucose sensor data. The higher the TIR the better the glucose control. Percentages during the intervention period are averaged per participant, thus obtaining 2 TIRs for each participant (one Observation TIR and one Intervention TIR). A linear regression analysis is performed to infer the impact (if any) of the duration and frequency of participants' interaction with the Web-Based Simulation Tool (predictor variables) on variations in TIR between Observation and Intervention periods (response variable).
Predictor variable 1: Number of simulations per participant per week. Predictor variable 2: Minutes of interaction with the Web-Based Simulation Tool per participant per week. Response variable: Intervention TIR - Observation TIR. The higher the response variable the better the outcome. |
First Week (Observation) and Following 4 Weeks (Intervention) | |
Other | Potential Correlation Between System Use and Changes in Perceived Regimen Distress at Baseline and Week 5 (Post-intervention) | Perceived regimen distress is estimated at Baseline and Week 5 (Post-intervention) using the Diabetes Distress Scale (DDS). Scores range from 1 to 6 (from Not a problem to A very serious problem). Participants' responses to the DSS's regimen distress items are summed and divided by the number of items in that scale. Higher scores mean a worse outcome. Scores at week 5 are compared with scores at baseline and used in a linear regression analysis to infer the impact (if any) of the duration and frequency of participants' interaction with the Web-Based Simulation Tool (predictor variables) on variations in treatment satisfaction (response variable).
Predictor variable 1: Number of simulations per participant per week. Predictor variable 2: Minutes of interaction with the Web-Based Simulation Tool per participant per week. Response variable: Regimen distress score at week 5 - Regimen distress score at baseline. The higher the response variable the worse. |
Baseline and Week 5 (Post-intervention) | |
Other | Potential Correlation Between System Use and Changes in Perceived Emotional Burden at Baseline and Week 5 (Post-intervention) | Perceived emotional burden is estimated at Baseline and Week 5 (Post-intervention) using the Diabetes Distress Scale (DDS). Scores range from 1 to 6 (from Not a problem to a very serious problem). Participants' responses to the DSS's emotional burden items are summed and divided by the number of items in that scale. Higher scores mean a worse outcome. Scores at week 5 are compared with scores at baseline and used in a linear regression analysis to infer the impact (if any) of the duration and frequency of participants' interaction with the Web-Based Simulation Tool (predictor variables) on variations in treatment satisfaction (response variable).
Predictor variable 1: Number of simulations per participant per week. Predictor variable 2: Minutes of interaction with the Web-Based Simulation Tool per participant per week. Response variable: Emotional burden score at week 5 - Emotional burden score at baseline. The higher the response variable the worse. |
Baseline and Week 5 (Post-intervention) | |
Primary | Technology Expectation and Technology Acceptance Questionnaires: Perceived Burdens and Benefits at Baseline and Week 5 (Post-intervention) | Technology Expectation (TE) and Technology Acceptance (TA) questionnaires are made of 27 items. Responses to the TE questionnaire were collected at week 0 (baseline), and responses to the TA questionnaire at week 5 (post-intervention). Each questionnaire has 5 categories: burdens (14 items), benefits (10 items), ease of use, usefulness, and trustworthiness (last 3, 1 item each). Items are scored on a 5-point Likert scale ranging from 1 to 5 (from strongly disagree to strongly agree for burdens and benefits, and from very poor to excellent for ease of use, usefulness, and trustworthiness). Here we report the results for burdens and benefits. The original 1-to-5 scale is converted to a 0-to-4 scale, the mean scores for burdens and benefits are averaged and then converted into a percentage ranging from 0% to 100%. Higher percentages mean a better outcome for benefits and a worse outcome for burdens. | Baseline and Week 5 (Post-intervention) | |
Primary | Technology Expectation and Technology Acceptance Questionnaires: Perceived Ease of Use, Usefulness and Trustworthiness of the System at Baseline and Week 5 (Post-intervention) | Technology Expectation (TE) and Technology Acceptance (TA) questionnaires are made of 27 items. Responses to the TE questionnaire were collected at week 0 (baseline), and responses to the TA questionnaire at week 5 (post-intervention). Each questionnaire has 5 categories: burdens (14 items), benefits (10 items), ease of use, usefulness, and trustworthiness (last 3, 1 item each). Items are scored on a 5-point Likert scale ranging from 1 to 5 (from strongly disagree to strongly agree for burdens and benefits, and from very poor to excellent for ease of use, usefulness, and trustworthiness). Here we report the results for ease of use, usefulness, and trustworthiness of the system. Higher scores mean a better outcome. | Baseline and Week 5 (Post-intervention) | |
Secondary | Diabetes Distress Scale at Baseline and Week 5 (Post-intervention) | The Diabetes Distress Scale (DDS) is a 17-item scale that yields a total diabetes distress score plus 4 subscale scores: Emotional burden (5 items), regimen distress (5 items), interpersonal distress (3 items) and physician distress (4 items). Scores range from 1 to 6 (from Not a problem to A very serious problem). To compute the total diabetes distress score and the 4 subscale scores, participants' responses in each scale are summed and divided by the corresponding number of items. A mean item score lower than 2.0 is considered little or no distress, between 2.0 and 2.9 is considered moderate distress, and higher than 3.0 is considered high distress. Thus, higher scores mean a worse outcome. | Baseline and Week 5 (Post-intervention) |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05653518 -
Artificial Pancreas Technology to Reduce Glycemic Variability and Improve Cardiovascular Health in Type 1 Diabetes
|
N/A | |
Enrolling by invitation |
NCT05515939 -
Evaluating the InPen in Pediatric Type 1 Diabetes
|
||
Completed |
NCT05109520 -
Evaluation of Glycemic Control and Quality of Life in Adults With Type 1 Diabetes During Continuous Glucose Monitoring When Switching to Insulin Glargine 300 U/mL
|
||
Recruiting |
NCT04016987 -
Automated Structured Education Based on an App and AI in Chinese Patients With Type 1 Diabetes
|
N/A | |
Active, not recruiting |
NCT04190368 -
Team Clinic: Virtual Expansion of an Innovative Multi-Disciplinary Care Model for Adolescents and Young Adults With Type 1 Diabetes
|
N/A | |
Recruiting |
NCT05413005 -
Efficacy of Extracorporeal Photopheresis (ECP) in the Treatment of Type 1 Diabetes Mellitus
|
Early Phase 1 | |
Active, not recruiting |
NCT04668612 -
Dual-wave Boluses in Children With Type 1 Diabetes Insulin Boluses in Children With Type 1 Diabetes
|
N/A | |
Completed |
NCT02837094 -
Enhanced Epidermal Antigen Specific Immunotherapy Trial -1
|
Phase 1 | |
Recruiting |
NCT05414409 -
The Gut Microbiome in Type 1 Diabetes and Mechanism of Metformin Action
|
Phase 2 | |
Recruiting |
NCT05670366 -
The Integration of Physical Activity Into the Clinical Decision Process of People With Type 1 Diabetes
|
N/A | |
Active, not recruiting |
NCT05418699 -
Real-life Data From Diabetic Patients on Closed-loop Pumps
|
||
Completed |
NCT04084171 -
Safety of Artificial Pancreas Therapy in Preschoolers, Age 2-6
|
N/A | |
Recruiting |
NCT06144554 -
Post Market Registry for the Omnipod 5 System in Children and Adults With Type 1 Diabetes
|
||
Recruiting |
NCT05379686 -
Low-Dose Glucagon and Advanced Hybrid Closed-Loop System for Prevention of Exercise-Induced Hypoglycaemia in People With Type 1 Diabetes
|
N/A | |
Recruiting |
NCT05153070 -
Ciclosporin Followed by Low-dose IL-2 in Patients With Recently Diagnosed Type 1 Diabetes
|
Phase 2 | |
Completed |
NCT05281614 -
Immune Effects of Vedolizumab With or Without Anti-TNF Pre-treatment in T1D
|
Early Phase 1 | |
Withdrawn |
NCT04259775 -
Guided User-initiated Insulin Dose Enhancements (GUIDE) to Improve Outcomes for Youth With Type 1 Diabetes
|
N/A | |
Active, not recruiting |
NCT01600924 -
Study on the Assessment of Determinants of Muscle and Bone Strength Abnormalities in Diabetes
|
||
Completed |
NCT02750527 -
Pediatric Population Screening for Type 1 Diabetes and Familial Hypercholesterolemia in Lower Saxony, Germany
|
||
Completed |
NCT02855307 -
Closed-loop Control of Glucose Levels (Artificial Pancreas) During Postprandial Exercise in Adults With Type 1 Diabetes
|
Phase 2 |