Type 1 Diabetes Clinical Trial
Official title:
Development of a Context-aware Glucose Prediction Algorithm in Patients With Type 1 Diabetes
Verified date | July 2023 |
Source | Oregon Health and Science University |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
Automated Insulin Delivery (AID) systems have now become an important standard-of-care for people with T1D and have demonstrated a reduction, but not elimination, of hypoglycemia during long-term studies. One limitation of current AID systems is that they have no knowledge about the context or environment that a person is currently experiencing. Contextual patterns can potentially improve the performance of an AID by recognizing environments or patterns of living that are related to changes in glucose. The team at OHSU is developing a context-aware glucose prediction algorithm that will capture context data from the patient both indoors and outdoors. This context data will be provided to the algorithm to allow for detecting contextual patterns that might relate to high or low glucose. The goal of this study will be the creation of a data set that will include contextual patterns along with glucose, insulin and physiological data.
Status | Completed |
Enrollment | 30 |
Est. completion date | January 3, 2022 |
Est. primary completion date | December 23, 2021 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 18 Years to 65 Years |
Eligibility | Inclusion Criteria: - Diagnosis of type 1 diabetes mellitus for at least 1 year. - Male or female subjects 18 to 65 years of age. - Physically willing and able to perform 30 min of exercise (as determined by the investigator after reviewing the subject's activity level). - Current use of an insulin pump for at least 3 months. - A1C <10.5% at the time of screening. - Willingness to follow all study procedures, including attending all clinic visits. - Willingness to sign informed consent and HIPAA documents. Exclusion Criteria: - Female of childbearing potential who is pregnant or intending to become pregnant or breast-feeding, or is not using adequate contraceptive methods. Acceptable contraception includes birth control pill / patch / vaginal ring, Depo-Provera, Norplant, an IUD, the double barrier method (the woman uses a diaphragm and spermicide and the man uses a condom), or abstinence. - Any cardiovascular disease, defined as a clinically significant EKG abnormality at the time of screening or any history of: stroke, heart failure, myocardial infarction, angina pectoris, or coronary arterial bypass graft or angioplasty. Diagnosis of 2nd or 3rd degree heart block or any non-physiological arrhythmia judged by the investigator to be exclusionary. - Renal insufficiency (GFR < 60 ml/min, using the MDRD equation as reported by the OHSU laboratory). - Liver failure, cirrhosis, or any other liver disease that compromises liver function as determined by the investigator. - Hematocrit of less than 36% for men, less than 32% for women. - History of severe hypoglycemia during the past 12 months prior to screening visit or hypoglycemia unawareness as judged by the investigator. Subjects will complete a hypoglycemia awareness questionnaire. Subjects will be excluded for four or more R responses. - Adrenal insufficiency. - Any active infection. - Known or suspected abuse of alcohol, narcotics, or illicit drugs. - Seizure disorder. - Active foot ulceration. - Peripheral arterial disease. - Major surgical operation within 30 days prior to screening. - Use of an investigational drug within 30 days prior to screening. - Chronic usage of any immunosuppressive medication (such as cyclosporine, azathioprine, sirolimus, or tacrolimus). - Bleeding disorder or platelet count below 50,000. - Current administration of oral or parenteral corticosteroids. - Any life threatening disease, including malignant neoplasms and medical history of malignant neoplasms within the past 5 years prior to screening (except basal and squamous cell skin cancer). - Beta blockers or non-dihydropyridine calcium channel blockers. - Current use of any medication intended to lower glucose other than insulin (ex. use of liraglutide). - A positive response to any of the questions from the Physical Activity Readiness Questionnaire with one exception: subject will not be excluded if he/she takes a single blood pressure medication that doesn't impact heart rate and blood pressure is controlled on the medication (blood pressure is less than 140/90 mmHg). - Any chest discomfort with physical activity, including pain or pressure, or other types of discomfort. - Any clinically significant disease or disorder which in the opinion of the Investigator may jeopardize the subject's safety or compliance with the protocol. |
Country | Name | City | State |
---|---|---|---|
United States | Oregon Health and Science University | Portland | Oregon |
Lead Sponsor | Collaborator |
---|---|
Oregon Health and Science University | National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK) |
United States,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Comparison of the Mean Absolute Relative Difference When Including Patterns in Hypoglycemia Prediction. | We used our recently published long short term memory neural network (LSTM) to predict sensor glucose 30-minutes in advance across the entire 4-week study duration when glucose was < 70 mg/dL. We then used the context-aware pattern recognition algorithm to predict when hypoglycemia would occur 30-minutes in the future, and if hypoglycemia was predicted, we included a bias correction that is specific to the hypogylcemia region of glucose measurements. The outcome measure shows the reduction of MARD when the LSTM is corrected using the pattern-based bias correction algorithm. MARD is calculated by subtracting the new sensor glucose - reference value dividing by the reference value. A negative value means that the MARD was reduced. The LSTM is being compared with Dexcom G6 CGM values to determine the MARD. Physiologically relevant thresholds are less than 55 mg/dl, less than 70 mg/dl, above 180 mg/dl and above 250 mg/dl. The Dexcom G6 target range is 70-180 mg/dl. | 28 days | |
Primary | Comparison of the Mean Relative Difference When Including Patterns in Hypoglycemia Prediction. | We used our recently published long short term memory neural network (LSTM) to predict glucose 30-minutes in advance across the entire 4-week study duration when glucose was < 70 mg/dL. We then used the context-aware pattern recognition algorithm to predict when hypoglycemia would occur 30-minutes in the future, and if hypoglycemia was predicted, we included a bias correction that is specific to the hypogylcemia region of glucose measurements. The outcome measure shows the reduction of mean relative difference (MRD) when the LSTM is corrected using the pattern-based bias correction algorithm. MARD is calculated by subtracting the new sensor glucose - reference value dividing by the reference value. A negative value means that the MARD was reduced. The LSTM is being compared with Dexcom G6 CGM values to determine the MARD. Physiologically relevant thresholds are less than 55 mg/dl, less than 70 mg/dl, above 180 mg/dl and above 250 mg/dl. The Dexcom G6 target range is 70-180 mg/dl. | 28 days |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05653518 -
Artificial Pancreas Technology to Reduce Glycemic Variability and Improve Cardiovascular Health in Type 1 Diabetes
|
N/A | |
Enrolling by invitation |
NCT05515939 -
Evaluating the InPen in Pediatric Type 1 Diabetes
|
||
Completed |
NCT05109520 -
Evaluation of Glycemic Control and Quality of Life in Adults With Type 1 Diabetes During Continuous Glucose Monitoring When Switching to Insulin Glargine 300 U/mL
|
||
Recruiting |
NCT04016987 -
Automated Structured Education Based on an App and AI in Chinese Patients With Type 1 Diabetes
|
N/A | |
Active, not recruiting |
NCT04190368 -
Team Clinic: Virtual Expansion of an Innovative Multi-Disciplinary Care Model for Adolescents and Young Adults With Type 1 Diabetes
|
N/A | |
Recruiting |
NCT05413005 -
Efficacy of Extracorporeal Photopheresis (ECP) in the Treatment of Type 1 Diabetes Mellitus
|
Early Phase 1 | |
Active, not recruiting |
NCT04668612 -
Dual-wave Boluses in Children With Type 1 Diabetes Insulin Boluses in Children With Type 1 Diabetes
|
N/A | |
Completed |
NCT02837094 -
Enhanced Epidermal Antigen Specific Immunotherapy Trial -1
|
Phase 1 | |
Recruiting |
NCT05414409 -
The Gut Microbiome in Type 1 Diabetes and Mechanism of Metformin Action
|
Phase 2 | |
Recruiting |
NCT05670366 -
The Integration of Physical Activity Into the Clinical Decision Process of People With Type 1 Diabetes
|
N/A | |
Active, not recruiting |
NCT05418699 -
Real-life Data From Diabetic Patients on Closed-loop Pumps
|
||
Completed |
NCT04084171 -
Safety of Artificial Pancreas Therapy in Preschoolers, Age 2-6
|
N/A | |
Recruiting |
NCT06144554 -
Post Market Registry for the Omnipod 5 System in Children and Adults With Type 1 Diabetes
|
||
Recruiting |
NCT05153070 -
Ciclosporin Followed by Low-dose IL-2 in Patients With Recently Diagnosed Type 1 Diabetes
|
Phase 2 | |
Recruiting |
NCT05379686 -
Low-Dose Glucagon and Advanced Hybrid Closed-Loop System for Prevention of Exercise-Induced Hypoglycaemia in People With Type 1 Diabetes
|
N/A | |
Completed |
NCT05281614 -
Immune Effects of Vedolizumab With or Without Anti-TNF Pre-treatment in T1D
|
Early Phase 1 | |
Withdrawn |
NCT04259775 -
Guided User-initiated Insulin Dose Enhancements (GUIDE) to Improve Outcomes for Youth With Type 1 Diabetes
|
N/A | |
Active, not recruiting |
NCT01600924 -
Study on the Assessment of Determinants of Muscle and Bone Strength Abnormalities in Diabetes
|
||
Completed |
NCT02914886 -
Beneficial Effect of Insulin Glulisine by Lipoatrophy and Type 1 Diabetes (LAS)
|
Phase 4 | |
Completed |
NCT02897557 -
Insulet Artificial Pancreas Early Feasibility Study
|
N/A |