Type 1 Diabetes Clinical Trial
Official title:
Reduction of Nocturnal Hypoglycemia by Using Predictive Algorithms and Pump Suspension: An Outpatient Pilot Feasibility and Efficacy Study
The purpose of this study is to see whether low blood sugar at night can be reduced by using
a system that turns off the insulin pump automatically. The study system includes a
combination continuous glucose monitor (CGM)/ insulin pump made by Medtronic MiniMed, Inc
and a regular laptop computer that runs a computer program that predicts low blood sugar. It
works by (1) measuring the glucose levels under the skin with a continuous glucose monitor,
(2) using a computer program on a laptop to predict what will happen to the glucose level
over the next 35-55 minutes, and (3) turning off the insulin pump when the computer program
predicts that low blood sugar will occur.
This study has several phases and will take about 3 months for a patient to complete.
Patients will use the Medtronic CGM with the Enlite sensor at home for 10-15 days to be sure
that they are able and willing to use this system and to determine if they meet the
investigators study criteria to proceed with the next phase of the study. Patients will be
provided teaching on how to use CGM data in real time. If a patient is not using a Medtronic
CGM already, the patient will first use one at home for 10-15 days to be sure that he/she is
able and willing to use it. If a patient is already using a Medtronic CGM, then his/her most
recent 10-15 days of data will be used to find out if he/she is eligible. Those who need to
complete the CGM run-in phase will have an extra office visit for training.
If eligible to continue in the study, patients will need to use the study system for 5
nights at home so that the investigators can make sure they are able to use it correctly.
After that, patients will be asked to use the study system each night for an additional 6 to
8 weeks. If the system is active and predicts that a patient's blood sugar will become low,
the insulin pump will shut off for up to 2 hours.
The study will include about 45 individuals at 3 clinical centers in the United States and
Canada.
Patients who are eligible for the clinical trial initially will use a Medtronic Continuous
Glucose Monitor (CGM) at home to verify that the subject is able to use the CGM and insert
sensors. Subjects already using a Medtronic CGM will skip this phase, provided that the
eligibility criteria for CGM use and the study are met.
Patients who meet criteria for sensor use and the study will then use the closed-loop system
at home for 5 days to demonstrate their ability to use the system and submit study data to
the Coordinating Center.
Patients who successfully demonstrate their ability to use the system at home as described
above will be eligible for the randomized trial phase. This phase consists of use of the
full system as an outpatient for approximately 42 nights:
- Each night the blood glucose level will be checked with the study home blood glucose
(BG) meter and used to perform a calibration of the CGM. This calibration must occur no
more than 90 minutes prior to activation of the system. NOTE: Patients will be
instructed to calibrate the CGM per manufacturer guidelines.
- Then the system will be activated, linking the CGM and insulin pump to the computer at
the bedside.
- A randomization schedule on the laptop will be used to determine whether the 'pump shut
off' application will be active that night or not.
- Patients will be blinded as to whether the pump shut off is active when a session is
initiated each night.
- There will not be an alarm if the pump shuts off. The CGM alarm will be set to 60 mg/dL
(3.3 mmol/L). When a CGM alarm occurs, the patient will be asked to measure the blood
glucose with a BG meter, if he/she is aware of the alarm.
- The time period for outcome assessment each night will be from the time the system is
activated until it is turned off in the morning
- Pump shut off, when it occurs, will be for up to 2 hours. Multiple instances of pump
suspension can occur if there are recurrent predictions of hypoglycemia during the
night.
- Patients will be asked to check blood glucose with the study BG meter, blood ketones
with the study ketone meter, and urine ketones with a ketone strip each morning prior
to breakfast and enter the results on the study laptop. The patient will be instructed
to contact the study physician if the blood glucose or ketone readings are out of an
expected range. Patients will be contacted if these morning safety values are not
reported as required or are out of range.
- Patients will be asked to record all overnight carbohydrate intake on the study laptop.
- Patients will be asked to perform periodic data uploads using the study laptop.
Monitoring processes will ensure that the patient is contacted if these uploads do not
occur as required, or if review of an upload reveals any extreme, prolonged episodes of
low or high blood glucose readings, or elevated morning blood glucose, blood ketone, or
urine ketone values.
Upon completion of the study, patients as well as study clinicians will be asked to complete
a questionnaire regarding use of the study system.
There will be one follow-up visit after 21 days in the clinical trial and a second follow-up
visit after the completion of 42 nights of successful study system use. A successful night
of study system use is defined as use of the system for at least four hours. Phone contacts
with the patients will be made once a week.
;
Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Parallel Assignment, Masking: Open Label, Primary Purpose: Prevention
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05653518 -
Artificial Pancreas Technology to Reduce Glycemic Variability and Improve Cardiovascular Health in Type 1 Diabetes
|
N/A | |
Enrolling by invitation |
NCT05515939 -
Evaluating the InPen in Pediatric Type 1 Diabetes
|
||
Completed |
NCT05109520 -
Evaluation of Glycemic Control and Quality of Life in Adults With Type 1 Diabetes During Continuous Glucose Monitoring When Switching to Insulin Glargine 300 U/mL
|
||
Recruiting |
NCT04016987 -
Automated Structured Education Based on an App and AI in Chinese Patients With Type 1 Diabetes
|
N/A | |
Active, not recruiting |
NCT04190368 -
Team Clinic: Virtual Expansion of an Innovative Multi-Disciplinary Care Model for Adolescents and Young Adults With Type 1 Diabetes
|
N/A | |
Recruiting |
NCT05413005 -
Efficacy of Extracorporeal Photopheresis (ECP) in the Treatment of Type 1 Diabetes Mellitus
|
Early Phase 1 | |
Active, not recruiting |
NCT04668612 -
Dual-wave Boluses in Children With Type 1 Diabetes Insulin Boluses in Children With Type 1 Diabetes
|
N/A | |
Completed |
NCT02837094 -
Enhanced Epidermal Antigen Specific Immunotherapy Trial -1
|
Phase 1 | |
Recruiting |
NCT05414409 -
The Gut Microbiome in Type 1 Diabetes and Mechanism of Metformin Action
|
Phase 2 | |
Recruiting |
NCT05670366 -
The Integration of Physical Activity Into the Clinical Decision Process of People With Type 1 Diabetes
|
N/A | |
Active, not recruiting |
NCT05418699 -
Real-life Data From Diabetic Patients on Closed-loop Pumps
|
||
Completed |
NCT04084171 -
Safety of Artificial Pancreas Therapy in Preschoolers, Age 2-6
|
N/A | |
Recruiting |
NCT06144554 -
Post Market Registry for the Omnipod 5 System in Children and Adults With Type 1 Diabetes
|
||
Recruiting |
NCT05153070 -
Ciclosporin Followed by Low-dose IL-2 in Patients With Recently Diagnosed Type 1 Diabetes
|
Phase 2 | |
Recruiting |
NCT05379686 -
Low-Dose Glucagon and Advanced Hybrid Closed-Loop System for Prevention of Exercise-Induced Hypoglycaemia in People With Type 1 Diabetes
|
N/A | |
Completed |
NCT05281614 -
Immune Effects of Vedolizumab With or Without Anti-TNF Pre-treatment in T1D
|
Early Phase 1 | |
Withdrawn |
NCT04259775 -
Guided User-initiated Insulin Dose Enhancements (GUIDE) to Improve Outcomes for Youth With Type 1 Diabetes
|
N/A | |
Active, not recruiting |
NCT01600924 -
Study on the Assessment of Determinants of Muscle and Bone Strength Abnormalities in Diabetes
|
||
Completed |
NCT02897557 -
Insulet Artificial Pancreas Early Feasibility Study
|
N/A | |
Completed |
NCT02855307 -
Closed-loop Control of Glucose Levels (Artificial Pancreas) During Postprandial Exercise in Adults With Type 1 Diabetes
|
Phase 2 |