Type 1 Diabetes Mellitus Clinical Trial
Official title:
A Randomized Cross-over Trial Evaluating Automated Insulin Delivery Technologies on Hypoglycemia and Quality of Life in Elderly Adults With Type 1 Diabetes
A multi-center, randomized, crossover trial consisting of three sequential 12-week periods, with the HCL feature used during one period, the PLGS feature used during one period and SAP therapy (control) during one period. The crossover trial will be preceded by a run-in phase in which participants will receive training using the study devices (Dexcom G6 and Tandem t:slim X2 pump). After the last crossover period, participants will be given the opportunity to use study devices for an additional 12 weeks to assess preference of system use (PLGS, HCL or SAP) and associated characteristics, durability and safety in a more real-world setting with less frequent study contact.
Automated insulin delivery (AID) technologies hold the promise of optimizing glycemic control and reducing the burden of diabetes care for patients with Type 1 Diabetes (T1D). However, clinical trials of lower burden AID technologies have not included older adults in sufficient numbers to allow for focused evaluation of efficacy and quality of life (QOL) impacts that may differ from those observed in younger age groups. Most notably, primary endpoints have focused on reducing hyperglycemia, while avoidance of hypoglycemia is of upmost concern for older adults with T1D. T1D Exchange clinic registry data have shown severe hypoglycemia (SH) occurs more commonly in older adults with longstanding T1D than in younger individuals with events occurring just as often with HbA1c levels >8.0% as with HbA1c levels <7.0%. These data do not support the strategy of "raising the HbA1c" as being an effective approach for hypoglycemia prevention in older adults with T1D. In addition to acutely altered mental status, hypoglycemia is associated with an increased risk for falls leading to fractures, car accidents, emergency room (ER) visits, hospitalizations, and mortality resulting in substantial societal costs. The occurrence of hypoglycemia, hypoglycemia unawareness and fear of hypoglycemia have adverse effects on overall QOL of both individuals with T1D and their families. While continuous glucose monitoring (CGM) technology alone has the potential to be beneficial in reducing hypoglycemia in older patients, our preliminary data from the Wireless Innovations for Seniors with Diabetes Mellitus (WISDM) trial shows a majority of patients still have frequent hypoglycemia even when using CGM. Thus, knowledge of CGM alone may not be sufficient to avoid hypoglycemia in this population. Predictive low-glucose suspend algorithms have particular promise when the primary goal is hypoglycemia avoidance rather than glucose reduction. Whether the added complexity of closed loop systems provides additional glycemic benefit is not known. There is a critical need to determine whether automated insulin delivery can reduce hypoglycemia in the older adult population with T1D. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04476472 -
Omnipod Horizon™ Automated Glucose Control System Preschool Cohort
|
N/A | |
Completed |
NCT03635437 -
Evaluation of Safety and Diabetes Status Upon Oral Treatment With GABA in Patients With Longstanding Type-1 Diabetes
|
Phase 1/Phase 2 | |
Completed |
NCT04909580 -
Decision Coaching for Youth and Parents Considering Insulin Delivery Methods for Type 1 Diabetes
|
N/A | |
Active, not recruiting |
NCT00679042 -
Islet Transplantation in Type 1 Diabetic Patients Using the University of Illinois at Chicago (UIC) Protocol
|
Phase 3 | |
Completed |
NCT03293082 -
Preschool CGM Use and Glucose Variability in Type 1 Diabetes
|
N/A | |
Completed |
NCT02527265 -
Afrezza Safety and Pharmacokinetics Study in Pediatric Patients
|
Phase 2 | |
Completed |
NCT03738865 -
G-Pen Compared to Glucagen Hypokit for Severe Hypoglycemia Rescue in Adults With Type 1 Diabetes
|
Phase 3 | |
Completed |
NCT03240432 -
Wireless Innovation for Seniors With Diabetes Mellitus
|
N/A | |
Completed |
NCT03168867 -
Effectiveness Trial of an E-Health Intervention To Support Diabetes Care in Minority Youth (3Ms)
|
N/A | |
Completed |
NCT03674281 -
The VRIF Trial: Hypoglycemia Reduction With Automated-Insulin Delivery System
|
N/A | |
Completed |
NCT03669770 -
Ultrasound Classification and Grading of Lipohypertrophy and Its Impact on Glucose Variability in Type 1 Diabetes
|
||
Recruiting |
NCT03682640 -
Azithromycin Insulin Diet Intervention Trial in Type 1 Diabetes
|
Phase 2 | |
Recruiting |
NCT04096794 -
Chinese Alliance for Type 1 Diabetes Multi-center Collaborative Research
|
||
Completed |
NCT02882737 -
The Impact of Subcutaneous Glucagon Before, During and After Exercise a Study in Patients With Type 1 Diabetes Mellitus
|
N/A | |
Recruiting |
NCT02745808 -
Injectable Collagen Scaffold™ Combined With HUC-MSCs for the Improvement of Erectile Function in Men With Diabetes
|
Phase 1 | |
Withdrawn |
NCT02579148 -
Collagen Scaffolds Loaded With HUCMSCs for the Improvement of Erectile Function in Men With Diabetes
|
Phase 1 | |
Completed |
NCT02558491 -
Feasibility of a Decision Support System to Reduce Glucose Variability in Subject With T1DM
|
N/A | |
Completed |
NCT02596204 -
Diabetes Care Transformation: Diabetes Data Registry and Intensive Remote Monitoring
|
N/A | |
Withdrawn |
NCT02518022 -
How to be Safe With Alcoholic Drinks in Diabetes
|
N/A | |
Completed |
NCT02562313 -
A Trial Investigating the Continuous Subcutaneous Insulin Infusion of a Liquid Formulation of BioChaperone Insulin Lispro in Comparison to Humalog®
|
Phase 1 |