Clinical Trials Logo

Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT03963219
Other study ID # 15SM2847
Secondary ID DOCUMAS NUMBER
Status Recruiting
Phase N/A
First received
Last updated
Start date August 22, 2019
Est. completion date June 30, 2021

Study information

Verified date October 2020
Source Imperial College London
Contact Monika Reddy
Phone 020 3312 6037
Email m.reddy@imperial.ac.uk
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The main objective of this study is to assess safety and efficacy of the ABC4D compared to standard therapy (standard bolus calculator) in adults with type 1 diabetes on multiple daily injections (MDI) of insulin in an out-of-clinic setting. Hypothesis: ABC4D is non-inferior to a standard bolus calculator and has an equivalent impact on time in target in adults with type 1 diabetes on MDI


Description:

The novel decision support algorithm is based on case-based reasoning (CBR). CBR is an artificial intelligence technique that tries to solve newly encountered problems by applying the solutions learned from solved problems encountered in the past (10). The CBR algorithm requires the following input for each insulin dose recommendation: - Time of day - Capillary blood glucose - Meal carbohydrate intake (g) - Type of meal CHO (fast, medium or slow absorption) - Pre- or post-meal exercise if within 4 hours of the meal (intensity: moderate or intense) These parameters make up the case problem presented to the CBR algorithm. Using this information the algorithm will find a similar case scenario from the pool of previously encountered cases and recommend an improved solution (insulin dose) to achieve the best possible outcome (post-prandial blood glucose). The insulin recommendation application runs locally on a standard operating system such as iOs5.x or Android within a commercially available smartphone. It contains the CBR based decision support algorithm as well as information of past successful cases. Opening the decision support application on the smartphone leads to the main menu, which provides a link to the submenu for requesting a new recommendation. Every calculated recommendation needs to be accepted or declined manually, and the latter option requires the user to enter the adjusted amount of insulin that has been delivered. In addition, the main menu enables the user to view logged data such as recent glucose levels, meal/exercise events and previous insulin dose advices. The glucose sensors that will be used throughout the clinical validation studies are the Enlite sensor (CE marked,manufactured by Medtronic) or the Dexcom sensor (CE marked, manufactured by Dexcom). They are subcutaneous sensor which sit just under the skin and sample interstitial fluid using an enzyme electrode. A small voltage is applied across the sensor and a current is fed back to the sensor instrumentation. This current is proportional to the glucose concentration in interstitial fluid and is calibrated against blood glucose a minimum of 12-hourly. In phase 2 and 3 the CGM will be blinded and either calibrated retrospectively using the iPro2 system (CE marked, manufactured by Medtronic) or calibrated in real-time using the Dexcom CGM system (however the CGM will be blinded to the subject). The iPro2 consist of a recorder that will be attached to the Enlite sensor and at the end of 6 days the data will be downloaded to the Medtronic Carelink iPro software. The Dexcom CGM data will be downloaded to the DiaSend/Dexcom Studio software. In phase 4 Dexcom real-time CGM (i.e subjects will be able to see their CGM data at all times) will be used continuously throughout the study. In Phase 5 the latest commercially available version of the Dexcom RT-CGM (Dexcom G6) will be used in accordance with manufacturer's user guide and data will automatically be stored to Dexcom Clarity. All data will be anonymised. The non-CE marked component of the intervention (The ABC4D device which is a novel bolus calculator for type 1 diabetes) remains the same and any adjustments to the algorithm will be documented with new version numbers as usual. The latest commercially available version of the Dexcom RT-CGM (Dexcom G6) will be used and this has got CE-mark approval. Two additional components to automatically collect additional information will be used in Phase 5: 1. Insulin pen caps allow automatic logging insulin doses delivered from the insulin pen. The participant will be provided with the pen cap that is compatible with their insulin pen. InPen (Companion Medical). The InPen is a CE-marked device. GoCap (Common Sensing). The GoCap is classed as a non-medical device and therefore does not require CE-mark in Europe. 2. FitBit Charge 2 HR (Fitbit) to collect physical activity data. The Fitbit Charge 2 HR is classed as a non-medical device. An overview of the components of the ABC4D system for Phase 5 has been included in the Phase 5 section of the protocol and in the corresponding PIS. In order to demonstrate safety and efficacy of the CBR algorithm, an in-silico study using the UVa-Padova T1DM simulator (11) was done and showed good results. The simulator was developed from human data and takes into account sensor errors, sensor placement, route of insulin administration and meal-time glucose absorption.


Recruitment information / eligibility

Status Recruiting
Enrollment 37
Est. completion date June 30, 2021
Est. primary completion date June 30, 2021
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: - Adults over 18 years of age - HbA1c between 7.0% and 9.0% - Type 1 diabetes confirmed on the basis of clinical features and a fasting c-peptide <200 pmol/L - Type 1 diabetes for greater than 3 years - On an intensified multiple dose insulin injection regimen for > 6 months (MDI) - Structured education (either group or 1:1) Exclusion Criteria: - Pregnant or planning pregnancy - Breastfeeding - Enrolled in other clinical trials - Have active malignancy or under investigation for malignancy - Severe visual impairment - Reduced manual dexterity - Unable to participate due to other factors, as assessed by the Chief Investigator - Shift worker - Allergy or intolerance to insulin aspart

Study Design


Intervention

Device:
ABC4D
The complete integrated system consists of a smartphone that holds the advanced decision support algorithm. The system requires regular updates of cases derived from continuous glucose monitoring (CGM) data. Each new case includes information about the problem (e.g. capillary blood glucose, meal information and physical exercise), solution (recommended insulin dose) and outcome (post-prandial blood glucose).
Standard Bolus Calculator
Standard bolus calculator

Locations

Country Name City State
United Kingdom Imperial College Clinical Research Facility London

Sponsors (2)

Lead Sponsor Collaborator
Imperial College London DexCom, Inc.

Country where clinical trial is conducted

United Kingdom, 

Outcome

Type Measure Description Time frame Safety issue
Primary % Time blood glucose in target, day time assess by device % time blood glucose spent in target (3.9-10mmol/L, 70-180mg/dL) during daytime (0700-2200) 32 weeks
See also
  Status Clinical Trial Phase
Completed NCT04476472 - Omnipod Horizon™ Automated Glucose Control System Preschool Cohort N/A
Completed NCT03635437 - Evaluation of Safety and Diabetes Status Upon Oral Treatment With GABA in Patients With Longstanding Type-1 Diabetes Phase 1/Phase 2
Completed NCT04909580 - Decision Coaching for Youth and Parents Considering Insulin Delivery Methods for Type 1 Diabetes N/A
Active, not recruiting NCT00679042 - Islet Transplantation in Type 1 Diabetic Patients Using the University of Illinois at Chicago (UIC) Protocol Phase 3
Completed NCT03293082 - Preschool CGM Use and Glucose Variability in Type 1 Diabetes N/A
Completed NCT04016662 - Automated Insulin Delivery in Elderly With Type 1 Diabetes (AIDE T1D) Phase 4
Completed NCT02527265 - Afrezza Safety and Pharmacokinetics Study in Pediatric Patients Phase 2
Completed NCT03738865 - G-Pen Compared to Glucagen Hypokit for Severe Hypoglycemia Rescue in Adults With Type 1 Diabetes Phase 3
Completed NCT03240432 - Wireless Innovation for Seniors With Diabetes Mellitus N/A
Completed NCT03168867 - Effectiveness Trial of an E-Health Intervention To Support Diabetes Care in Minority Youth (3Ms) N/A
Completed NCT03674281 - The VRIF Trial: Hypoglycemia Reduction With Automated-Insulin Delivery System N/A
Completed NCT03669770 - Ultrasound Classification and Grading of Lipohypertrophy and Its Impact on Glucose Variability in Type 1 Diabetes
Recruiting NCT03682640 - Azithromycin Insulin Diet Intervention Trial in Type 1 Diabetes Phase 2
Recruiting NCT04096794 - Chinese Alliance for Type 1 Diabetes Multi-center Collaborative Research
Completed NCT02882737 - The Impact of Subcutaneous Glucagon Before, During and After Exercise a Study in Patients With Type 1 Diabetes Mellitus N/A
Recruiting NCT02745808 - Injectable Collagen Scaffold™ Combined With HUC-MSCs for the Improvement of Erectile Function in Men With Diabetes Phase 1
Completed NCT02596204 - Diabetes Care Transformation: Diabetes Data Registry and Intensive Remote Monitoring N/A
Completed NCT02562313 - A Trial Investigating the Continuous Subcutaneous Insulin Infusion of a Liquid Formulation of BioChaperone Insulin Lispro in Comparison to Humalog® Phase 1
Completed NCT02558491 - Feasibility of a Decision Support System to Reduce Glucose Variability in Subject With T1DM N/A
Withdrawn NCT02518022 - How to be Safe With Alcoholic Drinks in Diabetes N/A