Type 1 Diabetes Mellitus Clinical Trial
— FLAIROfficial title:
Home Use of MD-Logic Automated Insulin Delivery System: Safety and Efficacy
Verified date | May 2020 |
Source | HealthPartners Institute |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
Adolescents and young adults with type 1 diabetes often have a difficult time achieving good glucose control, which is so important in reducing the risk for diabetes complications. Despite the use of multiple daily injections or insulin pumps and glucose sensors, there is still a need for many individuals to further improve glucose levels without causing low blood glucose levels (hypoglycemia) or adding to the daily burden of living with diabetes. Today an insulin pump can receive glucose readings from a continuous glucose monitor and adjust the insulin delivery in an attempt to keep glucose levels in a more optimal range. These systems are called hybrid closed loop (HCL). This means that much of the insulin delivery is automated, yet the patient still interacts regularly with the system, particularly to help determine the insulin dose to deliver to cover a meal. Results of early studies using HCL systems in adolescents and adults with type 1 diabetes are encouraging. The objective of this study is to compare the efficacy and safety of the automated insulin delivery (AID) system with proportional integral-derivative (PID) algorithm (Minimed 670G 3.0 HCL) to an AID system with combined PID and Fuzzy Logic Algorithm (Minimed 670G 4.0 Advanced Hybrid Closed-Loop (AHCL)). The trial will test the hypothesis that the Minimed AHCL can reduce daytime hyperglycemia, currently the biggest challenge for AID systems, without increasing hypoglycemia. Up to 124 adolescents and young adults (ages 14-<30) will be recruited to test each system for three months in a randomized crossover trial. Investigators will compare how effective each hybrid closed loop system is at preventing high blood glucose readings during the day. The investigators will also evaluate the safety of each system and how participants adjust to the daily use of the technology.
Status | Completed |
Enrollment | 126 |
Est. completion date | April 20, 2020 |
Est. primary completion date | April 20, 2020 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 14 Years to 30 Years |
Eligibility | Inclusion Criteria: 1. Type 1 diabetes mellitus (as diagnosed clinically) for at least one year 2. Age 14-<30 years at enrollment 3. For females, not currently known to be pregnant, be breast-feeding or planning to become pregnant within the study duration. 4. Using an insulin pump or multiple daily injections of insulin 1. Participant must be able to obtain U-100 rapid acting insulin analogues, Aspart or Lispro, for use during the study (since these are the only insulins approved for the study pump and the study is not supplying insulin) 2. MDI users must be on a basal/bolus regimen 3. Participants must have a minimum total daily dose (TDD) of at least eight units 5. HbA1c from an approved HbA1c point of care analyzer with a value 7.0%-11.0% 6. Willingness or ability to do carbohydrate counting 7. In the investigator's judgment, able to understand and likely to be adherent to the protocol 8. For subjects <18 years old, living with one or more diabetes care partners (eg.g. parent/legal guardian), of whom at least one is committed to participating in study training for emergency procedures for severe hypoglycemia and able to contact the participant in case of an emergency. 9. Have adequate internet access and a computer system that meets requirements for uploading data. 10. For participants currently using CGM or insulin pump, willingness to discontinue personal CGM and pump when using the study CGM and pumps (note: including implantable CGMs). Exclusion Criteria: Individuals meeting any of the following exclusion criteria at screening will be excluded from study participation: 1. Concomitant disease that influences metabolic control or HbA1c interpretation (e.g. anemia, significantly impaired hepatic function, confirmed gastroparesis, renal failure, history of adrenal insufficiency, sickle cell disease, haemoglobinopathy, or has received red blood cell transfusion or erythropoietin within three months prior to time of screening) or other medical condition which, in the Investigator's opinion, may compromise patient safety, affect outcome assessments, or affect the participant's ability to follow the protocol 2. Oral or parenteral glucocorticoids taken within 1 month prior to enrollment, or plans to take oral or parenteral glucocorticoids within the planned study duration. Exceptions: Short term oral or parenteral glucocorticoids up to seven days 3. Use of antidiabetic agents other than insulin 4. Use of other medications, which in the judgment of the investigator would be a contraindication to participation in the study 5. One or more episodes of severe hypoglycemia (hypoglycemia requiring treatment by another person) within the previous six months 6. Known allergy to medical grade adhesives 7. Participation in another study of a medical device or drug that could affect glucose measurements or glucose management or receipt of any investigational medical product within 1 month prior to enrollment 8. Current eating disorder such as anorexia or bulimia 9. Currently abusing illicit drugs, marijuana, prescription drugs, or alcohol 10. Visual impairment or hearing loss, which may compromise the participant's ability to perform all study procedures safely, as determined by the investigator 11. One or more episodes of diabetic ketoacidosis (DKA) requiring hospitalization within six months prior to screening 12. Working night shifts 13. Untreated celiac disease, hyperthyroidism, or hypothyroidism 14. Clinically significant nephropathy (eGFR <45 mL/min) or on dialysis. Creatinine to determine eGFR must have been obtained as part of usual care within 12 months prior to enrollment (if not available, at time of enrollment, screening can proceed but it must be available prior to randomization) |
Country | Name | City | State |
---|---|---|---|
Germany | Kinderkrankenhaus Auf Der Bult | Hannover | |
Israel | Schneider Children's Medical Center of Israel | Petah Tikva | |
Slovenia | University of Ljubljana | Ljubljana | |
United States | Joslin Diabetes Center | Boston | Massachusetts |
United States | University of Florida | Gainesville | Florida |
United States | Yale University | New Haven | Connecticut |
United States | International Diabetes Center | Saint Louis Park | Minnesota |
Lead Sponsor | Collaborator |
---|---|
HealthPartners Institute | International Diabetes Center at Park Nicollet, Jaeb Center for Health Research, Joslin Diabetes Center, Kinderkrankenhaus auf der Bult, Medtronic, National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK), Schneider Children's Medical Center, Israel, Stanford University, University of Florida, University of Ljubljana, University of Minnesota, Yale University |
United States, Germany, Israel, Slovenia,
Bergenstal RM, Garg S, Weinzimer SA, Buckingham BA, Bode BW, Tamborlane WV, Kaufman FR. Safety of a Hybrid Closed-Loop Insulin Delivery System in Patients With Type 1 Diabetes. JAMA. 2016 Oct 4;316(13):1407-1408. doi: 10.1001/jama.2016.11708. — View Citation
Bergenstal RM, Klonoff DC, Garg SK, Bode BW, Meredith M, Slover RH, Ahmann AJ, Welsh JB, Lee SW, Kaufman FR; ASPIRE In-Home Study Group. Threshold-based insulin-pump interruption for reduction of hypoglycemia. N Engl J Med. 2013 Jul 18;369(3):224-32. doi: 10.1056/NEJMoa1303576. Epub 2013 Jun 22. — View Citation
Bergenstal RM, Tamborlane WV, Ahmann A, Buse JB, Dailey G, Davis SN, Joyce C, Peoples T, Perkins BA, Welsh JB, Willi SM, Wood MA; STAR 3 Study Group. Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes. N Engl J Med. 2010 Jul 22;363(4):311-20. doi: 10.1056/NEJMoa1002853. Epub 2010 Jun 29. Erratum in: N Engl J Med. 2010 Sep 9;363(11):1092. — View Citation
Nimri R, Bratina N, Kordonouri O, Avbelj Stefanija M, Fath M, Biester T, Muller I, Atlas E, Miller S, Fogel A, Phillip M, Danne T, Battelino T. MD-Logic overnight type 1 diabetes control in home settings: A multicentre, multinational, single blind randomized trial. Diabetes Obes Metab. 2017 Apr;19(4):553-561. doi: 10.1111/dom.12852. Epub 2017 Jan 19. — View Citation
Nimri R, Muller I, Atlas E, Miller S, Fogel A, Bratina N, Kordonouri O, Battelino T, Danne T, Phillip M. MD-Logic overnight control for 6 weeks of home use in patients with type 1 diabetes: randomized crossover trial. Diabetes Care. 2014 Nov;37(11):3025-32. doi: 10.2337/dc14-0835. Epub 2014 Jul 30. — View Citation
Nimri R, Muller I, Atlas E, Miller S, Kordonouri O, Bratina N, Tsioli C, Stefanija MA, Danne T, Battelino T, Phillip M. Night glucose control with MD-Logic artificial pancreas in home setting: a single blind, randomized crossover trial-interim analysis. Pediatr Diabetes. 2014 Mar;15(2):91-9. doi: 10.1111/pedi.12071. Epub 2013 Aug 15. — View Citation
Nimri R, Phillip M. Artificial pancreas: fuzzy logic and control of glycemia. Curr Opin Endocrinol Diabetes Obes. 2014 Aug;21(4):251-6. doi: 10.1097/MED.0000000000000073. Review. — View Citation
Phillip M, Battelino T, Atlas E, Kordonouri O, Bratina N, Miller S, Biester T, Stefanija MA, Muller I, Nimri R, Danne T. Nocturnal glucose control with an artificial pancreas at a diabetes camp. N Engl J Med. 2013 Feb 28;368(9):824-33. doi: 10.1056/NEJMoa1206881. — View Citation
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Other | Amount of Total Insulin at Daytime, Nighttime and Post-meal | Based on sensor glucose data | 12 weeks for each arm of the crossover | |
Other | Human Factors and Diabetes Technology Attitude and Human Factors Questionnaires | Surveys completed by participants. The Glucose Monitoring Satisfaction Survey is 15 items on a 1-5 scale; Total score calculated as mean of all item scores; higher scores indicate greater satisfaction. The Diabetes Distress Scale is 17 items on a 1-6 scale; Total score calculated as mean of all item scores; higher score denotes more distress. The Hypoglycemia Confidence Survey is 8 items on a 1-4 scale; Total score calculated as mean of all item scores; higher score denotes more confidence. The Diabetes Technology Attitudes Survey is 5 items on a 0-4 scale; Total score calculated as sum of all item scores; higher score denotes more satisfaction with diabetes technology. The Adult INSPIRE Survey is 22 items on a 1-5 scale; Total score calculated as mean of all item scores; higher score denotes more satisfaction with AID. The Adolescent INSPIRE Survey is 17 items on a 1-5 scale; Total score calculated as mean of all item scores; higher score denotes more satisfaction with AID. | Time Frame: Screening visit, at initiation (Day 0); end of crossover period 1 (Week 14 through 20, depending); and end of crossover period 2 (Week 26-32, depending) | |
Primary | Percentage of Time Glucose Levels Were > 180 mg/dL (10.0 mmol/L) From 6 AM to 11:59 PM | Glucose levels based on sensor glucose data | 12 weeks for each arm of the crossover | |
Primary | Non-inferiority for Percent of Time <54 mg/dL (3.0 mmol/L) During the Entire 24-hour Period. | Glucose levels based on sensor glucose data | 12 weeks for each arm of the crossover | |
Secondary | Efficacy: CGM Derived Indices: Mean Glucose Only | Continuous Glucose Monitoring derived indices over the first 84 days of each treatment period for 24 hours (excluding time before auto mode is turned on). Glucose levels based on sensor glucose data for Mean glucose. | 12 weeks for each arm of the crossover | |
Secondary | Efficacy: CGM Derived Indices | CGM derived indices over the first 84 days of each treatment period for 24 hours. Glucose levels based on sensor glucose data for coefficient of variation; percentage of sensor glucose readings in the range of 70 to 180 mg/dL (3.9-10.0 mmol/L) and 70 to 140 mg/dL (3.9 to 7.8 mmol/L); percentage of sensor glucose readings >180 mg/dL (daytime is a co-primary outcome) and >250 mg/dL (10.0 and 13.9 mmol/L, respectively) | 12 weeks for each arm of the crossover | |
Secondary | Efficacy: Amount of Total, Basal and Bolus Daily Insulin Over the First 84 Days of Each Treatment Period | Amount of total, basal, and bolus daily insulin over the first 84 days of each treatment period (excluding time before auto mode is turned on) for 24 hours. Glucose levels based on sensor glucose data. Sum of daytime and nighttime values may not equal total daily values due to rounding. | 12 weeks for each arm of the crossover | |
Secondary | Efficacy: HbA1c | Glycated hemoglobin (HbA1c) was measured at a central laboratory (Advanced Research and Diagnostic Laboratory University of Minnesota, MN, USA) at randomization and at the end of each period by use of an International Federation of Clinical Chemistry and Laboratory Medicine aligned method (Tosoh HPLC Glycohemoglobin Analyzer, Tosoh Medics, San Francisco, CA, USA; coefficient of variation range 1.4 1.9%). | Time Frame: End of crossover period 1 (Week 14 through 20, depending); and end of crossover period 2 (Week 26-32, depending) | |
Secondary | Efficacy: BMI for Participants Age =18 Years | Height and weight. Body mass index (BMI) is a person's weight in kilograms divided by the square of height in meters. BMI is interpreted using standard weight status categories. These categories are the same for men and women of all body types and ages. Below 18.5 : Underweight; 18.5 - 24.9: Normal or Healthy Weight; 25.0 - 29.9: Overweight; 30.0 and Above: Obese. | Time Frame: Screening visit, at initiation (Day 0); randomization (Week 2 through 8, depending); end of crossover period 1 (Week 14 through 20, depending); and end of crossover period 2 (Week 26-32, depending) | |
Secondary | Efficacy: BMI Percentile for Participants Age <18 Years | Height and weight based on CDC standards of measurement. Age and gender adjusted. | Time Frame: Screening visit, at initiation (Day 0); randomization (Week 2 through 8, depending); end of crossover period 1 (Week 14 through 20, depending); and end of crossover period 2 (Week 26-32, depending) | |
Secondary | Key Safety Outcome 1) Percentage of Time Sensor Glucose Readings Were <54 mg/dL and <70 mg/dL (3.0 and 3.9 mmol/L, Respectively | Glucose levels based on sensor glucose data | 12 weeks for each arm of the crossover | |
Secondary | Key Safety Outcome 2) Number of DKA Events | DKA as defined by the Diabetes Control and Complications Trial (DCCT) and described below:
Symptoms such as polyuria, polydipsia, nausea, or vomiting; Serum ketones >1.5 mmol/L or large/moderate urine ketones; Either arterial blood pH <7.30 or venous pH <7.24 or serum bicarbonate <15; and Treatment provided in a health care facility |
12 weeks for each arm of the crossover | |
Secondary | Key Safety Outcome 3) Number of Severe Hypoglycemia Events | Severe hypoglycemia event as defined by the Diabetes Control and Complications Trial (DCCT) and described below:
The event required assistance of another person due to altered consciousness, and required another person to actively administer carbohydrate, glucagon, or other resuscitative actions. This means that the participant was impaired cognitively to the point that he/she was unable to treat himself/herself, was unable to verbalize his/ her needs, was incoherent, disoriented, and/or combative, or experienced seizure or loss of consciousness. |
12 weeks for each arm of the crossover |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04476472 -
Omnipod Horizon™ Automated Glucose Control System Preschool Cohort
|
N/A | |
Completed |
NCT03635437 -
Evaluation of Safety and Diabetes Status Upon Oral Treatment With GABA in Patients With Longstanding Type-1 Diabetes
|
Phase 1/Phase 2 | |
Completed |
NCT04909580 -
Decision Coaching for Youth and Parents Considering Insulin Delivery Methods for Type 1 Diabetes
|
N/A | |
Active, not recruiting |
NCT00679042 -
Islet Transplantation in Type 1 Diabetic Patients Using the University of Illinois at Chicago (UIC) Protocol
|
Phase 3 | |
Completed |
NCT03293082 -
Preschool CGM Use and Glucose Variability in Type 1 Diabetes
|
N/A | |
Completed |
NCT04016662 -
Automated Insulin Delivery in Elderly With Type 1 Diabetes (AIDE T1D)
|
Phase 4 | |
Completed |
NCT02527265 -
Afrezza Safety and Pharmacokinetics Study in Pediatric Patients
|
Phase 2 | |
Completed |
NCT03738865 -
G-Pen Compared to Glucagen Hypokit for Severe Hypoglycemia Rescue in Adults With Type 1 Diabetes
|
Phase 3 | |
Completed |
NCT03240432 -
Wireless Innovation for Seniors With Diabetes Mellitus
|
N/A | |
Completed |
NCT03168867 -
Effectiveness Trial of an E-Health Intervention To Support Diabetes Care in Minority Youth (3Ms)
|
N/A | |
Completed |
NCT03674281 -
The VRIF Trial: Hypoglycemia Reduction With Automated-Insulin Delivery System
|
N/A | |
Completed |
NCT03669770 -
Ultrasound Classification and Grading of Lipohypertrophy and Its Impact on Glucose Variability in Type 1 Diabetes
|
||
Recruiting |
NCT03682640 -
Azithromycin Insulin Diet Intervention Trial in Type 1 Diabetes
|
Phase 2 | |
Recruiting |
NCT04096794 -
Chinese Alliance for Type 1 Diabetes Multi-center Collaborative Research
|
||
Completed |
NCT02882737 -
The Impact of Subcutaneous Glucagon Before, During and After Exercise a Study in Patients With Type 1 Diabetes Mellitus
|
N/A | |
Recruiting |
NCT02745808 -
Injectable Collagen Scaffold™ Combined With HUC-MSCs for the Improvement of Erectile Function in Men With Diabetes
|
Phase 1 | |
Completed |
NCT02596204 -
Diabetes Care Transformation: Diabetes Data Registry and Intensive Remote Monitoring
|
N/A | |
Completed |
NCT02562313 -
A Trial Investigating the Continuous Subcutaneous Insulin Infusion of a Liquid Formulation of BioChaperone Insulin Lispro in Comparison to Humalog®
|
Phase 1 | |
Completed |
NCT02558491 -
Feasibility of a Decision Support System to Reduce Glucose Variability in Subject With T1DM
|
N/A | |
Withdrawn |
NCT02579148 -
Collagen Scaffolds Loaded With HUCMSCs for the Improvement of Erectile Function in Men With Diabetes
|
Phase 1 |