Clinical Trials Logo

Clinical Trial Summary

The objectives of this outpatient research study are (1) to assess the ability of this automated system to be operated by a subject with limited professional oversight; (2) to assess whether the new devices (Dexcom Gen 4 sensors, Motorola ES400 smart phone, iDex pump controller) will reduce the frequency of hardware and data communication lapses seen in the previous system; and (3) to measure the degree of glucose control achievable with this automated system. The system will adjust blood glucose by administering insulin and glucagon. Insulin is a hormone that lowers blood glucose and will be given nearly continuously during this study. Glucagon raises blood glucose and will be automatically administered during hypoglycemia. Both are natural hormones made by people without diabetes. Each subject will have four devices placed on his abdomen: two Omnipod insulin pumps, one for delivering insulin and one for delivering glucagon, and two Dexcom G4 glucose sensors for measuring glucose. The two sensors will feed glucose data into Motorola smart phone master controller, which will calculate the correct amount of insulin or glucagon to deliver. The system will then send the command to the correct Omnipod through the iDex pod controller.

In this new system, the research subject will be able to monitor the progress of the study by use of the smart phone graphical user interface. The subject will have a companion with him/her during the entire study for safety purposes. Both the subject and companion will complete a training course on how to treat diabetic emergencies and how to operate the system. A study physician and technician will be in the hotel during each study and will be monitoring the study via a cloud-based data communication system. These studies will be carried out in a hotel setting.


Clinical Trial Description

The objective of the current human study is to verify the components of the Artificial Pancreas Control Software during an outpatient study. This master controller software is designed to be used in conjunction with two subcutaneous continuous glucose monitoring systems to regulate blood glucose levels as well as two Omnipod pumps, one for administering insulin and one for administering glucagon. The sensors communicate wirelessly with two sensor receivers which will be interfaced with the APC by wireless USB connection. The insulin and glucagon pumps will be controlled by the APC through a wireless USB connection. The algorithm included in the APC is an automated version of the Adaptive Proportional Derivative (APD) insulin and glucagon control algorithm, which was previously studied as an investigational device. The Automated APD has been studied in vivo (in 13 experiments, each 28 hr in length, with automated adjustment of pumps) and no serious adverse effects were noted. The APC will be tested in vivo during 28 hour experiments in an outpatient setting in preparation for home testing. ;


Study Design

Endpoint Classification: Efficacy Study, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT01871870
Study type Interventional
Source Legacy Health System
Contact
Status Completed
Phase Phase 2
Start date May 2013
Completion date October 2013

See also
  Status Clinical Trial Phase
Completed NCT04476472 - Omnipod Horizon™ Automated Glucose Control System Preschool Cohort N/A
Completed NCT03635437 - Evaluation of Safety and Diabetes Status Upon Oral Treatment With GABA in Patients With Longstanding Type-1 Diabetes Phase 1/Phase 2
Completed NCT04909580 - Decision Coaching for Youth and Parents Considering Insulin Delivery Methods for Type 1 Diabetes N/A
Active, not recruiting NCT00679042 - Islet Transplantation in Type 1 Diabetic Patients Using the University of Illinois at Chicago (UIC) Protocol Phase 3
Completed NCT03293082 - Preschool CGM Use and Glucose Variability in Type 1 Diabetes N/A
Completed NCT04016662 - Automated Insulin Delivery in Elderly With Type 1 Diabetes (AIDE T1D) Phase 4
Completed NCT02527265 - Afrezza Safety and Pharmacokinetics Study in Pediatric Patients Phase 2
Completed NCT03738865 - G-Pen Compared to Glucagen Hypokit for Severe Hypoglycemia Rescue in Adults With Type 1 Diabetes Phase 3
Completed NCT03240432 - Wireless Innovation for Seniors With Diabetes Mellitus N/A
Completed NCT03168867 - Effectiveness Trial of an E-Health Intervention To Support Diabetes Care in Minority Youth (3Ms) N/A
Completed NCT03674281 - The VRIF Trial: Hypoglycemia Reduction With Automated-Insulin Delivery System N/A
Completed NCT03669770 - Ultrasound Classification and Grading of Lipohypertrophy and Its Impact on Glucose Variability in Type 1 Diabetes
Recruiting NCT03682640 - Azithromycin Insulin Diet Intervention Trial in Type 1 Diabetes Phase 2
Recruiting NCT04096794 - Chinese Alliance for Type 1 Diabetes Multi-center Collaborative Research
Completed NCT02882737 - The Impact of Subcutaneous Glucagon Before, During and After Exercise a Study in Patients With Type 1 Diabetes Mellitus N/A
Recruiting NCT02745808 - Injectable Collagen Scaffold™ Combined With HUC-MSCs for the Improvement of Erectile Function in Men With Diabetes Phase 1
Completed NCT02596204 - Diabetes Care Transformation: Diabetes Data Registry and Intensive Remote Monitoring N/A
Withdrawn NCT02518022 - How to be Safe With Alcoholic Drinks in Diabetes N/A
Completed NCT02562313 - A Trial Investigating the Continuous Subcutaneous Insulin Infusion of a Liquid Formulation of BioChaperone Insulin Lispro in Comparison to Humalog® Phase 1
Completed NCT02558491 - Feasibility of a Decision Support System to Reduce Glucose Variability in Subject With T1DM N/A