Traumatic Lower Limb Injury Clinical Trial
Official title:
The Effects of Heel Distraction Height on Foot Loading With Carbon Fiber Custom Dynamic Orthoses
Carbon fiber custom dynamic orthoses (CDOs) and unloading ankle foot orthoses (AFOs) have shown varying levels of success in reducing forces acting on different regions of the bottom of the foot during gait. CDOs and unloading AFOs have shown differing offloading capabilities across different regions of the foots (hindfoot, midfoot, forefoot) which may be related to a distinct difference between CDOs and unloading AFOs: CDOs do not suspend, or distract, the foot away from the footplate. The purpose of this study is to determine the effects of CDOs and heel distraction height (the distance between the heel and the footplate) on foot loading during gait as well as patient reported pain, comfort, and smoothness.
Carbon fiber custom dynamic orthoses (CDOs) have been used to improve function, reduce pain, and offload the foot and ankle for individuals with a number of conditions affecting the lower extremity. CDOs consist of a proximal cuff that wraps around the leg just below the knee, a posterior carbon fiber strut that bends to store and return energy during mid to late stance, a semi-rigid carbon fiber footplate, and, in some cases, a foam heel wedge placed in the shoe. Unloading ankle foot orthoses (AFOs) have also been used for a number of lower extremity conditions, including traumatic injuries, in effort to reduce forces and pressure acting under the foot. Unloading AFOs have been created using many different designs, which include a proximal cuff just below the knee, a rigid strut (made of metal, plastic, etc.), and some sort of foot component (footplate, shoe, etc.). Both CDOs and unloading AFOs have shown varying levels of success in reducing forces acting on different regions of the bottom of the foot during gait. Based on previously published data and initial data collections, CDOs have been shown to successfully offload the forefoot during gait but have had differing results for the hindfoot and midfoot. Offloading AFOs have shown to reduce plantar pressures in the midfoot and hindfoot with some increases observed in the forefoot. The differences in loading may be related to a distinct difference between CDOs and unloading AFOs: CDOs do not suspend, or distract, the foot away from the footplate. The purpose of this study is to determine the effects of CDOs and heel distraction height (the distance between the heel and the footplate) on foot loading as well as patient reported pain and comfort. In this study, forces acting under the foot will be measured using wireless Loadsol insoles (Novel GMBH, St. Paul, MN) as participants walk without an orthosis (NoCDO) and with a CDO with three different posterior strut lengths resulting in three different levels of heel distraction (0cm, 1cm, 2cm) at self-selected and controlled speeds. Participants will be provided a lift for the contralateral limb to reduce the effects of leg length discrepancies during walking. Loadpad force measuring sensors (Novel GMBH, St. Paul, MN) will be used to measure forces within the CDO proximal cuff, ensuring it is fastened the same across testing conditions. After walking in each condition, participants will complete questionnaires concerning pain and orthosis comfort. ;