Clinical Trials Logo

Clinical Trial Summary

The evaluation of the bone, using several techniques and on several aspects will be the purpose to study the possible impact of the kidney transplant (and, extensively, the pre-transplant dialysis, the organ replacement and the immunosuppressive therapy) could have on the bone metabolism and on the density of the bone where the implants are placed. The assessment on the bone density only in a retrospectively selected population that underwent the same surgical procedure will help the comparison of the data to get a satisfactory conclusion. The evaluation of other clinical and instrumental parameters in the test group makes the kidney-transplant patients bone quality clear, and will consequently demonstrate if implants are a feasible therapy for these patients.


Clinical Trial Description

The primary purpose of this study is the evaluation of the effects of the kidney transplant on the periimplant bone density by the comparison with the density of healthy patients. The secondary purpose is obtaining clinical, histological and radiographic data to evaluate the effect of systemic conditions and its rebound on the insertion of fixtures.

Evaluation criteria

1. Control group: evaluation of the periimplant bone density (1 mm) next to the implant virtually planned using the CT editing software on the cone beam CT acquired in a retrospective sample of patients already treated with the insertion of a fixture in the molar or premolar edentulous site

2. Test group: periodontal evaluation with plaque index, bleeding on probing index and probing 1 month before operation.

3. Test group: evaluation of periimplant bone density (1 mm) in the fixture virtual-projected zone (the implant will be inserted there) with the CT acquisition and editing software.

4. Test group: evaluation of the implant stability after their insertion (primary stability) using the Resonance Frequence Analysis. ISQ (Implant Stability Quotient) value is expressed in 4 numbers (mesial, distal, buccal, lingual), average values of three measures acquired in each side.

5. Test group: evaluation of the implant stability immediately after the insertion calculating the insertional torque value (ITV) with an implant motor.

6. Test group: evaluation of the periimplant bone using an endoral periapical radiograph with Rinn device immediately after the operation.

7. Test group: histomorphological examination of the bone core sample made by a trephine resulted from the implant site preparation ;


Study Design

Observational Model: Case Control, Time Perspective: Prospective


Related Conditions & MeSH terms

  • Disorder Related to Renal Transplantation
  • Tooth Loss

NCT number NCT02513602
Study type Observational
Source University of Trieste
Contact Federico Berton, DDS
Phone 0403992254
Email fberton@units.it
Status Recruiting
Phase N/A
Start date May 2014
Completion date August 2022

See also
  Status Clinical Trial Phase
Recruiting NCT05498662 - An Observational Study of the T3 Pro Dental Implant System
Active, not recruiting NCT05311657 - Oral Health and Severe COPD
Completed NCT01237184 - Initial Stability of Posterior Maxillary Implants With Bicortical Fixation
Not yet recruiting NCT03521024 - Effect of Zirconia Implant Supported PEKK Crowns Versus Lithium Disilicate Crowns on Esthetics N/A
Recruiting NCT04856319 - The Effect of Pre-operative Single Dose Antibiotic Prophylaxis on the Post-operative Implant Success N/A
Active, not recruiting NCT05079542 - RCT of BLT Implants Used for Immediate vs Early Placement, Restored With Ceramic Crowns on Titanium Bonding Bases. N/A
Recruiting NCT03003819 - A Comparison of Two Socket Sealing Collagen Matrices for Extraction Socket Management N/A
Completed NCT02163395 - Performance Evaluation of FullCeram Implants in Single Tooth Gaps N/A
Completed NCT02996370 - Effect of I-Shape Incısıon Technique on Inter-Implant Papilla: A Prospective Randomized Clinical Trial N/A
Completed NCT02842385 - Soft Tissue Thickness on Submerged and Non Submerged Implants N/A
Withdrawn NCT00798031 - Case Series Evaluation of a Short Dental Implant N/A
Completed NCT04559802 - Submerged Versus Non-Submerged Healing of Implants Subjected To Contour Augmentation N/A
Completed NCT00018512 - Biological Specifications for Denture Designs Phase 2
Enrolling by invitation NCT05157009 - Immediate Implant Outcomes With and Without Bone Augmentation N/A
Active, not recruiting NCT04550689 - Comparison of Dimensional Changes After Tooth Extractions Between Xenograft and Allograft N/A
Terminated NCT03580798 - Ridge Preservation Comparing Simultaneous vs. Delayed Grafting N/A
Completed NCT05016401 - Performance and Safety of Use of the "KONTACT PERIO LEVEL" Transgingival Titanium Dental Implant
Not yet recruiting NCT06106321 - Primary and Secondary Elevations of Maxillary Sinuses: a Prospective Clinical Study in the Posterior Maxillary Region N/A
Not yet recruiting NCT05096897 - Oral Health-related Quality of Life (OHRQoL) in Patients With Inflammatory Bowel Disease (IBD)
Recruiting NCT04605445 - One vs Two Visits Root Canal Treatments in Infected Teeth N/A