Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT02868957
Other study ID # ECT14-02A-27
Secondary ID 10053907NRF-2013
Status Completed
Phase N/A
First received August 9, 2016
Last updated August 15, 2016
Start date January 2014
Est. completion date October 2014

Study information

Verified date August 2016
Source Seoul National University Gwanak Dental Hospital
Contact n/a
Is FDA regulated No
Health authority Korea: Institutional Review Board
Study type Interventional

Clinical Trial Summary

The objectives of this study were to compare the precision of two digital intraoral scanners from a series of repeat scan images, and to investigate the effect of the learning curve on changes in trueness when scanning the full arch of the oral cavity in actual patients.


Description:

Study Participants: This study was approved by the institutional review board of Ehwa Womans University Medical Center Mokdong Hospital, and dental hygienists who were suitable for the purpose of the study were selected (ECT14-02A-27). Participants were assigned one of four patients, and subsequently scanned the oral cavity of a single patient 10 times repeatedly over 4 days.

Study Design: The participants visited the dental clinic and performed scanning for 4 days. In order to investigate the difference in the precision and trueness of two types of intraoral scanners, the participants scanned the dental arch of a single patient 10 times using an assigned digital intraoral scanner. On the first day, either of the two types of scanners (iTero and Trios), and a patient were assigned. Then, the participants were trained in theory and practices of the assigned scanner, and subsequently, using it, scanned the dental arch of the assigned patient twice. On the second and third days, the dental arch of the same patient was scanned 3 times respectively, and on the fourth day, the experiment was finished after scanning the same patient twice.

Statistical Analyses: Collected data were analyzed using the SPSS Ver. 20.0 statistical package. For the determination of differences in the deviations according to the scanner, the independent two-sample t-test was conducted to examine the significance of the precision data. For comparisons of trueness according to repeated learning, the repeated measure ANOVA was used to test for differences between the scanners, clinical experience of the participants, and the scanning region within the same scanner group. The significance of time-dependent changes, and the interaction between the scanner group and time variables, were examined by within-subject tests. Differences between the scanner groups were examined by between-subject tests. The significance of the 10 consecutive scans and four visits within the scanner group, and the difference between the scanner groups at each time point, were examined by the post-hoc test, which was performed using the Bonferroni method as a multiple comparison (α= 0.05).


Recruitment information / eligibility

Status Completed
Enrollment 20
Est. completion date October 2014
Est. primary completion date August 2014
Accepts healthy volunteers Accepts Healthy Volunteers
Gender Female
Age group 20 Years to 35 Years
Eligibility Inclusion Criteria:

- The selection criteria for the participants were as follows: they had the clinical experiences between 3 - 11 years, understood the purpose of the study well, gave their consent, and were able to carry out a 4-day learning course. Those who were inadequate to carry out the study mentally or physically.

Exclusion Criteria:

- Applicant who was considered inappropriate .for this study by the principal investigator was excluded from the selection

Study Design

Allocation: Non-Randomized, Intervention Model: Parallel Assignment, Masking: Open Label, Primary Purpose: Health Services Research


Related Conditions & MeSH terms


Intervention

Other:
impression data from reference scanner
To create a reference images for the assessment of the trueness, the impressions of the upper and lower arch of the oral cavities of four patients were taken using a polyether impression material (3M ESPE Soft Monophase; Minnesota Mining and Manufacturing Co.), and the intaglio scanning was performed on the impression body using a desktop scanner. Scanned images were transformed to the Standard Tessellation Language (STL) file format, and used as reference images.
Device:
iTero
The participants visited the dental clinic and performed scanning for 4 days. In order to investigate the difference in the precision and trueness of iTero intraoral scanners, the participants scanned the dental arch of a single patient 10 times using an assigned digital intraoral scanner.
Trios
The participants visited the dental clinic and performed scanning for 4 days. In order to investigate the difference in the precision and trueness of Trios intraoral scanners, the participants scanned the dental arch of a single patient 10 times using an assigned digital intraoral scanner. .

Locations

Country Name City State
Korea, Republic of Seoul National University Gwanak Dental Hospital Seoul

Sponsors (1)

Lead Sponsor Collaborator
Seoul National University Gwanak Dental Hospital

Country where clinical trial is conducted

Korea, Republic of, 

References & Publications (5)

Ender A, Mehl A. Influence of scanning strategies on the accuracy of digital intraoral scanning systems. Int J Comput Dent. 2013;16(1):11-21. English, German. — View Citation

Feldman LS, Cao J, Andalib A, Fraser S, Fried GM. A method to characterize the learning curve for performance of a fundamental laparoscopic simulator task: defining "learning plateau" and "learning rate". Surgery. 2009 Aug;146(2):381-6. doi: 10.1016/j.surg.2009.02.021. Epub 2009 Jun 25. — View Citation

Lee SJ, Gallucci GO. Digital vs. conventional implant impressions: efficiency outcomes. Clin Oral Implants Res. 2013 Jan;24(1):111-5. doi: 10.1111/j.1600-0501.2012.02430.x. Epub 2012 Feb 22. — View Citation

Patzelt SB, Lamprinos C, Stampf S, Att W. The time efficiency of intraoral scanners: an in vitro comparative study. J Am Dent Assoc. 2014 Jun;145(6):542-51. doi: 10.14219/jada.2014.23. — View Citation

Yuzbasioglu E, Kurt H, Turunc R, Bilir H. Comparison of digital and conventional impression techniques: evaluation of patients' perception, treatment comfort, effectiveness and clinical outcomes. BMC Oral Health. 2014 Jan 30;14:10. doi: 10.1186/1472-6831-14-10. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Precision and trueness of intraoral scanners after repeated scanning practice assessed by Geomagic Verify Ver.20152.0 Assessment was done by registering pairs of scan images and calculating deviation by computer calculation in micrometers. One year Yes
Secondary Scan time required for full arch image acquisition in seconds Scan time was measured until the scanned image was satisfactory with reference to the standard quality by one inspector. up to one year Yes
See also
  Status Clinical Trial Phase
Not yet recruiting NCT05792800 - Dental Practitioners KAP Regarding Caries Preventive Measures in Cairo and Riyadah
Not yet recruiting NCT05792215 - KAP of Dental Practitioners Regarding CRA
Terminated NCT03871569 - Medico-economical Evaluation on Buccodental Teleexpertise in Nursing Home N/A
Active, not recruiting NCT04324008 - Clinical Comparison of Different Flowable Resin Composites N/A
Completed NCT02801552 - Regenerative Endodontic Procedure of Immature Permanent Teeth With Apical Periodontitis Using PRF N/A
Completed NCT06112366 - Comparison of Silk Suture and Tissue Adhesive for Wound Closure After Impacted Tooth N/A
Recruiting NCT04033380 - Clinical Efficacy of Ceramic vs Resin Block Endocrown N/A
Completed NCT04003493 - LifE Style, Nutrition and Oral Health in Care Givers (LENTO) N/A
Completed NCT03708510 - Clinical Evaluation of Two Low-shrinkage Composites N/A
Completed NCT06067542 - Effects of Chlorhexidine Toothpaste on Wound Healing After Impacted Tooth Extraction N/A
Completed NCT03556553 - Clinical Evaluation of a Self-Adhering Flowable Composite in Class I Cavities N/A
Completed NCT04291443 - Proteomics and Orthodontic Root Resorption N/A
Completed NCT03553966 - Hydroxyapatite-toothpaste and Enamel Caries in the Primary Dentition N/A
Recruiting NCT01805869 - Oral Specimen and Data Acquisition Study of Subjects Requiring Third Molar Removal
Completed NCT04385693 - Intentional Pulpotomy to Preserve Hopeless Molars N/A
Completed NCT02429947 - An Analysis of the Symptomatic Domains Most Relevant to Charcot Marie Tooth Neuropathy (CMT) Patients N/A
Recruiting NCT04029324 - Clinical Outcomes of Immediate Implant Placement and Early Implant Placement N/A
Recruiting NCT06212232 - A New Piezoelectric Technique in Third Molar Surgery N/A
Completed NCT04827693 - The Cortical Shield for Facial Bone Reconstruction
Completed NCT06280014 - Evaluation of the Effects of Mefenamic Acid and Dexketoprofen on Postoperative Wisdom Dental Surgery N/A