Thoracic Diseases Clinical Trial
Official title:
Interference of Biotin Supplementation in Biotin-streptavidin Platforms for Hormone Testing
The B vitamin biotin is widely available as an over the counter supplement, often advertised and used to promote health of hair, skin and nails. Commercially available over the counter biotin supplements contain dose ranges up to 10 mg/day (ie 333 times higher than the recommended dietary allowance). The biotin molecule is also sometimes used as part of the lab technology to measure hormone and protein levels in the blood. It is possible that high doses of ingested biotin may interfere with accurate hormone or protein measurement using biotin related in vitro measurement systems. Such interference, if present, could lead to misdiagnosis. The study will analyze laboratory levels obtained with streptavidin-biotin assay systems while ingesting biotin in currently available high dose supplements. The data will be compared to measurements obtained prior to and one week after stopping the biotin supplement.
Specimens will be collected by venipuncture at 3 time points, including baseline (time 0),
after one week of biotin supplementation (time 1, day 7), and then one week later (time 2,
day 14). The time 1 specimen will be drawn approximately 2 hours after the last ingested dose
of biotin on day 7. Specimen collection will include three 10 ml red top (no gel) tubes at
each timepoint.
Specimens will be separated for isolation of serum using routine methods of the clinical
chemistry laboratory. Serum will be stored at -80 degrees C until batch measurements as
described Measurements Biotin levels will be measured on each sample. Hormone measurements
will be performed using specific commercially available streptavidin-biotin assays and using
different analyzers as indicated below. Immunoassay methods, not employing
biotin-streptavidin methodology, will be used for negative assay controls.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04221880 -
Erector Spinae Plane Block Versus Perioperative Intravenous Lidocaine for Thoracotomy
|
N/A | |
Not yet recruiting |
NCT04538469 -
Absent Visitors: The Wider Implications of COVID-19 on Non-COVID Cardiothoracic ICU Patients, Relatives and Staff
|
||
Completed |
NCT01826994 -
Incremental Value of Point of Care H-FABP Testing in Primary Care Patients Suspected of Acute Coronary Syndrome
|
N/A | |
Completed |
NCT01860898 -
A Phase I Study of iPS Cell Generation From Patients With COPD
|
N/A | |
Recruiting |
NCT04887415 -
Respiratory Strength Training in Cardiac Surgical Patients
|
N/A | |
Completed |
NCT05033353 -
Ventilatory Influence on Cerebral Oxygenation During VATS
|
N/A | |
Completed |
NCT04498208 -
Immune Modulation by Enhanced vs Standard Prehabilitation Program Before Major Surgery
|
N/A | |
Completed |
NCT03768193 -
Deep Serratus Anterior Plane Block vs Surgically-placed Paravertebral Block for VATS Surgery
|
N/A | |
Completed |
NCT03307551 -
Evaluation of Automated Propofol Delivery in Patients Undergoing Thoracic Surgery
|
Phase 4 | |
Completed |
NCT03286400 -
Observational Registry Characterizing the CTAG Device With ACTIVE CONTROL
|
||
Recruiting |
NCT02971917 -
A Clinical Study of TRUVIEW ARTâ„¢(Advanced Reconstruction Tech)to Improve Image Quality on Chest Radiograph
|
N/A | |
Completed |
NCT02133235 -
The Need of Fiberoptic Bronchoscopy for Placing an Endobronchial Blocker
|
N/A | |
Completed |
NCT03922516 -
Accuracy of Ultra-Low-Dose-CT of the Chest Compared to Plain Film in an Unfiltered Emergency Department Patient Cohort
|
N/A | |
Recruiting |
NCT05851807 -
Intraoperative Lung Mechanics and Functional Evaluation in Post COVID-19 Thoracotomy Patients
|
||
Completed |
NCT03080831 -
TOnicity of Perioperative Maintenance SoluTions
|
Phase 4 | |
Completed |
NCT05173207 -
Respiratory-Swallow Coordination in Cardiothoracic Surgical Patients
|
||
Recruiting |
NCT05308771 -
To Investigate the Use of a New Syringe "Visual Pressure Control (VPC)" for Epidural Anesthesia in Children Surgery
|
N/A | |
Terminated |
NCT02391896 -
Design and Evaluation of Mobile X-ray for Rapid and Accurate Diagnosis of Thoracic Disease
|
N/A | |
Recruiting |
NCT05639400 -
Thoraflex Hybrid and Relay Extension Post-Approval Study
|
||
Completed |
NCT03144479 -
New Technique to Assess Correct Positioning of the Right-sided Double Lumen Tube
|
N/A |