Clinical Trial Summary

Transcranial electric stimulation (TES) motor evoked potential (MEP) monitoring is standard during surgery risking motor system injury. The stimuli are typically 5-pulse trains with a 4 ms interstimulus interval (ISI). The pulse duration (D) is often set to 50 or 500 µs. Both are effective, but setting D to the chronaxie would be physiologically optimal and limited data suggest that mean MEP chronaxie may be near 200 µs. When necessary, one can obtain larger MEPs by increasing current (I) or D to increase stimulus charge (Q = I × D). However, this also increases patient movement that can interfere with surgery and reduce MEP acquisition frequency. The main research question is whether increasing current or pulse duration when applying intraoperative neuromonitoring produces less patient movement during surgery. As such, the IOM ISIS System will be employed for neuromonitoring and an accelerometer will be used to quantify patient movement. The constant-current TES stimulators will be used in this study with a high-precision oscilloscope. Total intravenous anesthesia (TIVA), surgery and TES MEP monitoring will proceed routinely without modification and normally involves acquiring many MEPs over several hours. The only departure from standard care will be the placement of two small accelerometers and a brief MEP sequence before skin incision to determine chronaxie and compare the effect of an equivalent increase of I or D on MEP amplitude and movement.


Description:

Transcranial electric stimulation (TES) motor evoked potential (MEP) monitoring is standard during surgery risking motor system injury. The stimuli are typically 5-pulse trains with a 4 ms interstimulus interval (ISI). The pulse duration (D) is often set to 50 or 500 µs. Both are effective, but setting D to the chronaxie would be physiologically optimal and limited data suggest that mean MEP chronaxie may be near 200 µs. When necessary, one can obtain larger MEPs by increasing current (I) or D to increase stimulus charge (Q = I × D). However, this also increases patient movement that can interfere with surgery and reduce MEP acquisition frequency. Anecdotal observations suggest that increasing D may produce larger MEPs with less movement than increasing I, but there is no published support. If true, then the optimal D for monitoring may be above the chronaxie because less movement could facilitate more frequent MEP acquisition. Finally, there is ongoing controversy about constant-current or constant-voltage TES. However, with stable resistance (R) there is no fundamental reason to prefer one or the other since they are related by Ohm's law I = V/R. Also, since threshold current and voltage vary with D their maximum levels should also vary with selected D, which could be confusing. Instead, because the International Electrotechnical Commission 50 mJ safety limit is based on energy (E = I2 × D × R = V2 × D/R), it may be more logical to apply constant-energy TES that would provide a consistent 0-50 mJ selection range at any selected D. The primary objective is to assess whether intraoperative neuromonitoring with constant current or constant voltage produces less patient movement during surgery. The secondary objectives are to compare MEP amplitudes with the different setups, to estimate the true mean or median chronaxie and to develop the concept of constant-energy TES. The main research question is whether increasing current or pulse duration when applying intraoperative neuromonitoring produces less patient movement during surgery. As such, the IOM ISIS System will be employed for neuromonitoring and an accelerometer will be used to quantify patient movement. The constant-current TES stimulators will be used in this study with a high-precision oscilloscope. The calibration will assess 5-pulse trains with a 4 ms ISI and 100 mA output across a 1000 Ω resistor at 250, 500, and 1000 µs D. Measurements will include actual I and D of each pulse, and actual ISI. Total intravenous anesthesia (TIVA), surgery and TES MEP monitoring will proceed routinely without modification and normally involves acquiring many MEPs over several hours. The only departure from standard care will be the placement of two small accelerometers and a brief MEP sequence before skin incision to determine chronaxie and compare the effect of an equivalent increase of I or D on MEP amplitude and movement.


Recruitment information / eligibility

Status Recruiting
Enrollment 31
Est. completion date March 31, 2026
Est. primary completion date December 31, 2025
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: - Informed Consent signed by the subject - The patient has a supra- or infra-tentorial lesion requiring surgery - The patient is undergoing neurosurgery with the use of Intraoperative Monitoring (IOM) during surgery to protect functional tissue - The patient is older than 18 years Exclusion Criteria: - No need for Intraoperative Monitoring (IOM) - Vulnerable subjects (pregnant women, pregnant, impaired consciousness) - People who do not want to participate in the study - Emergency procedures in which no consent was obtained before the operation - Multiple surgeries on the same patient - Preoperative non-affected arm motor deficit (MRC <5), that is to say, no motor deficit of the arm ipsilateral to the surgery - Inhalational anesthesia - Persisting neuromuscular blockade

Study Design


Related Conditions & MeSH terms


Intervention

Device:
ISIS IOM System
The constant-current TES stimulators will be used in this study with a high-precision oscilloscope. The calibration will assess 5-pulse trains with a 4 ms ISI and 100 mA output across a 1000 ? resistor at 250, 500, and 1000 µs D. Measurements will include actual I and D of each pulse, and actual ISI. Total intravenous anesthesia (TIVA), surgery and TES MEP monitoring will proceed routinely without modification and normally involves acquiring many MEPs over several hours. The only departure from standard care will be the placement of two small accelerometers and a brief MEP sequence before skin incision to determine chronaxie and compare the effect of an equivalent increase of I or D on MEP amplitude and movement.

Locations

Country Name City State
Switzerland Dep. of Neurosurgery, Bern University Hospital Bern

Sponsors (1)

Lead Sponsor Collaborator
Insel Gruppe AG, University Hospital Bern

Country where clinical trial is conducted

Switzerland, 

References & Publications (5)

Abalkhail TM, MacDonald DB, AlThubaiti I, AlOtaibi FA, Stigsby B, Mokeem AA, AlHamoud IA, Hassounah MI, Baz SM, AlSemari A, AlDhalaan HM, Khan S. Intraoperative direct cortical stimulation motor evoked potentials: Stimulus parameter recommendations based on rheobase and chronaxie. Clin Neurophysiol. 2017 Nov;128(11):2300-2308. doi: 10.1016/j.clinph.2017.09.005. Epub 2017 Sep 28. — View Citation

Eng J. Sample size estimation: how many individuals should be studied? Radiology. 2003 May;227(2):309-13. doi: 10.1148/radiol.2272012051. — View Citation

Macdonald DB, Skinner S, Shils J, Yingling C; American Society of Neurophysiological Monitoring. Intraoperative motor evoked potential monitoring - a position statement by the American Society of Neurophysiological Monitoring. Clin Neurophysiol. 2013 Dec;124(12):2291-316. doi: 10.1016/j.clinph.2013.07.025. Epub 2013 Sep 18. — View Citation

MacDonald DB. Safety of intraoperative transcranial electrical stimulation motor evoked potential monitoring. J Clin Neurophysiol. 2002 Oct;19(5):416-29. doi: 10.1097/00004691-200210000-00005. — View Citation

Szelenyi A, Kothbauer KF, Deletis V. Transcranial electric stimulation for intraoperative motor evoked potential monitoring: Stimulation parameters and electrode montages. Clin Neurophysiol. 2007 Jul;118(7):1586-95. doi: 10.1016/j.clinph.2007.04.008. Epub 2007 May 15. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Comparison of the effect of a 2-fold increase of I or of D from threshold on patient movement Comparison of the effect of a 2-fold increase of I or of D from threshold on patient movement quantified by accelerometers on the patient's forehead and contralateral (non-affected) shoulder. During surgery, estimated on average to be about 4 hours
Secondary Comparing the effect of a 2-fold increase of I or of D from threshold on MEP amplitude Compare the effect of a 2-fold increase of I or of D from threshold on MEP amplitude as measured by the ISIS IOM System During surgery, estimated on average to be about 4 hours
Secondary Chronaxie The stimulation strength (in mA) necessary to elicit an MEP are measured with the different pulse durations (in µs) During surgery, estimated on average to be about 4 hours
See also
  Status Clinical Trial Phase
Recruiting NCT05583916 - Same Day Discharge for Video-Assisted Thoracoscopic Surgery (VATS) Lung Surgery N/A
Completed NCT04448041 - CRANE Feasibility Study: Nutritional Intervention for Patients Undergoing Cancer Surgery in Low- and Middle-Income Countries
Completed NCT03213314 - HepaT1ca: Quantifying Liver Health in Surgical Candidates for Liver Malignancies N/A
Enrolling by invitation NCT05534490 - Surgery and Functionality in Older Adults N/A
Recruiting NCT04792983 - Cognition and the Immunology of Postoperative Outcomes
Terminated NCT04612491 - Pre-operative Consultation on Patient Anxiety and First-time Mohs Micrographic Surgery
Recruiting NCT06397287 - PROM Project Urology
Recruiting NCT04444544 - Quality of Life and High-Risk Abdominal Cancer Surgery
Completed NCT04204785 - Noise in the OR at Induction: Patient and Anesthesiologists Perceptions N/A
Completed NCT03432429 - Real Time Tissue Characterisation Using Mass Spectrometry REI-EXCISE iKnife Study
Completed NCT04176822 - Designing Animated Movie for Preoperative Period N/A
Recruiting NCT05370404 - Prescribing vs. Recommending Over-The-Counter (PROTECT) Analgesics for Patients With Postoperative Pain: N/A
Not yet recruiting NCT05467319 - Ferric Derisomaltose/Iron Isomaltoside and Outcomes in the Recovery of Gynecologic Oncology ERAS Phase 3
Recruiting NCT04602429 - Children's Acute Surgical Abdomen Programme
Completed NCT03124901 - Accuracy of Noninvasive Pulse Oximeter Measurement of Hemoglobin for Rainbow DCI Sensor N/A
Completed NCT04595695 - The Effect of Clear Masks in Improving Patient Relationships N/A
Recruiting NCT06103136 - Maestro 1.0 Post-Market Registry
Completed NCT05346588 - THRIVE Feasibility Trial Phase 3
Completed NCT04059328 - Novel Surgical Checklists for Gynecologic Laparoscopy in Haiti
Recruiting NCT03697278 - Monitoring Postoperative Patient-controlled Analgesia (PCA) N/A