Clinical Trials Logo

Clinical Trial Details — Status: Active, not recruiting

Administrative data

NCT number NCT04218812
Other study ID # PROMAESIS
Secondary ID
Status Active, not recruiting
Phase N/A
First received
Last updated
Start date March 12, 2019
Est. completion date December 31, 2024

Study information

Verified date February 2024
Source Aarhus University Hospital
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

Electrical source imaging is part of the presurgical evaluation of patients with drug-resistant focal epilepsy. The software packages that will be used in this study have Declaration of Conformity within the European Economic Area (CE mark) for this specific medical use. In spite of being part of the clinical standard, the evidence for the accuracy and clinical utility of these methods are derived from several smaller-scale and retrospective studies. The PROMAESIS study will provide solid evidence of the accuracy and clinical utility of automated ESI.


Description:

One-third of patients with epilepsy have seizures resistant to pharmacotherapy. There are many approaches developed to control these seizures, yet epilepsy surgery is still the most common method. The crucial part of epilepsy surgery is to assess the epileptic zone in order to render patients seizure free. However, accurate localization of the epileptic zone is often challenging due to the multimodal approach. This contains semiology, EEG (obtained during long term video-EEG monitoring), magnetic resonance Imaging (MRI), in addition to certain cases, positron emission computed tomography (PET), and single photon emission computed tomography (SPECT) and magnetoencephalography (MEG). At present, in one of the third patients, seizure remains after epilepsy surgery. Therefore a new preoperative method should be improved to assess the epileptic zone. Automated ESI is a post-processing novel method that estimates the location in the brain of the source of the recorded EEG signals. The objective of this study is: 1. To determine the accuracy of ESI in localizing the epileptic focus. 2. To determine the clinical utility of ESI on clinical decision making Methods: Study design: a prospective diagnostic study in line with the Standards for Reporting Diagnostic Accuracy Studies (STARD). EEG was recorded using the International Federation of Clinical Neurophysiology (IFCN) electrode array of 25 electrodes including six electrodes in the Inferior temporal chain (F9/10, T9/10, and P9/10) in addition to the 19 electrodes of the 10-20 system. Electrode impedance was kept below 5 kilo-ohm. EEG was recorded with a sampling frequency of 256 Hz. The investigators will make a video on how to place the electrodes, to make sure all centers follow a standardized method. Multidisciplinary epilepsy teams classify that in the first step you should keep the multidisciplinary team blinded to the source imaging data, and make the implantation plan without the ESI results. Then show the ESI, adjust the plan and note the changes. The multidisciplinary teams in different centers will classify seizures into "types." A seizure type is a group of seizures that have stereotypical semiology and ictal EEG. Maximum 3 seizures are registered for per type. After Long Term Monitoring, they provide Epilog and Brain Electrical Source Analysis (BESA) teams with datasets including MRI and Long Term Monitoring recording for each patient. For uploading datasets, multicenter teams will use the platform developed by Epilog. Afterward, Epilog and BESA teams (blinded to patient information) will run the automated source imaging-both for interictal epileptiform discharge (EDs) and ictal signs. Both software packages have CE mark for ESI. Finally, the multidisciplinary teams take decisions in two steps: I. Considering all data, except ESI II. Adding ESI to all other data. At each step, the decisions are classified into one of the following categories: 1. Stop (operation not recommended) 2. Implantation of intracranial electrodes 3. Operation In addition, the changes are classified into one of the following categories: 1. No change - but concordant with the decision. 2. No change - but discordant with decision. 3. Change from stop to implantation. 4. Change from implantation to stop. 5. Change in implantation plan: implantation of additional sites (besides the ones planned in step-1). 6. Change from implantation of operation. 7. Change from operation to implantation. 8. Other (specify in free text). If changes are not related to all analyses results, it will be noted, which method(s) triggered the change (SLORETA-interictal / ictal; Equivalent Current Dipole - interictal/ictal; CLARA interictal/ictal). At one-year follow-up, the changes are categorized as useful or not useful. A change is defined useful as follows: (a) change from stop to Intracranial Recording: the Intracranial Recording localized the source; (b) change in implantation strategy: the electrode(s) implanted based on the source imaging identified the source; (c) change from implantation to operation: the patient became seizure-free.


Recruitment information / eligibility

Status Active, not recruiting
Enrollment 250
Est. completion date December 31, 2024
Est. primary completion date May 1, 2021
Accepts healthy volunteers No
Gender All
Age group 1 Year to 99 Years
Eligibility Inclusion Criteria: - Patients with drug resistant focal epilepsy, admitted to Epilepsy Monitoring Unit for presurgical evaluation, who are afterwards discussed at the multidisciplinary epilepsy surgery team meetings. Exclusion Criteria: - Patients who did not have a seizure during the monitoring.

Study Design


Intervention

Diagnostic Test:
No electrical source imaging (ESI)
For all patients: MRI, semiology, visual interpretation of EEG, and in selected cases, PET, SPECT
Automated electrical source imaging (ESI)
The automated source imaging consists of 2 phases Automated detection of EDs Source imaging of each spike cluster and seizure onset epoch.

Locations

Country Name City State
Austria Kepler University Clinic Linz
Austria Christian Doppler Klinik Salzburg
Czechia Brno Epilepsy Center Brno Czech Republic
Czechia Motol University Hospital Prague Czech Rebuplic
Denmark Danish Epilepsy Center Dianalund
Germany Freiburg University Freiburg Baden-Wurttemberg
Italy Carlo Besta Institure Milano
Italy Valencia University Hospital Venice
Portugal Centro Hospitalar e Universitário de Coimbra Coimbra
Portugal Hospital de Santa Maria Lisbon
Romania University Hospital Bucharest Bucharest
Spain Hospital del Mar Barcelona

Sponsors (13)

Lead Sponsor Collaborator
Sándor Beniczky Brno Epilepsy Center, Carlo Besta Institure, Milano, Centro Hospitalar e Universitário de Coimbra, E.P.E., Christian Doppler Klinik, Salzburg, Filadelfia Epilepsy Hospital, Freiburg University, Hospital de Santa Maria, Lisbon, Hospital del Mar, Kepler University Clinic, Linz, Motol University Hospital, Prague, University Hospital Bucharest (Adult), Valencia University Hospital

Countries where clinical trial is conducted

Austria,  Czechia,  Denmark,  Germany,  Italy,  Portugal,  Romania,  Spain, 

References & Publications (8)

Beniczky S, Lantz G, Rosenzweig I, Akeson P, Pedersen B, Pinborg LH, Ziebell M, Jespersen B, Fuglsang-Frederiksen A. Source localization of rhythmic ictal EEG activity: a study of diagnostic accuracy following STARD criteria. Epilepsia. 2013 Oct;54(10):1743-52. doi: 10.1111/epi.12339. Epub 2013 Aug 14. — View Citation

Boon P, D'Have M, Vanrumste B, Van Hoey G, Vonck K, Van Walleghem P, Caemaert J, Achten E, De Reuck J. Ictal source localization in presurgical patients with refractory epilepsy. J Clin Neurophysiol. 2002 Oct;19(5):461-8. doi: 10.1097/00004691-200210000-00009. — View Citation

Brodbeck V, Spinelli L, Lascano AM, Wissmeier M, Vargas MI, Vulliemoz S, Pollo C, Schaller K, Michel CM, Seeck M. Electroencephalographic source imaging: a prospective study of 152 operated epileptic patients. Brain. 2011 Oct;134(Pt 10):2887-97. doi: 10.1093/brain/awr243. — View Citation

Lascano AM, Perneger T, Vulliemoz S, Spinelli L, Garibotto V, Korff CM, Vargas MI, Michel CM, Seeck M. Yield of MRI, high-density electric source imaging (HD-ESI), SPECT and PET in epilepsy surgery candidates. Clin Neurophysiol. 2016 Jan;127(1):150-155. doi: 10.1016/j.clinph.2015.03.025. Epub 2015 May 9. — View Citation

Maliia MD, Meritam P, Scherg M, Fabricius M, Rubboli G, Mindruta I, Beniczky S. Epileptiform discharge propagation: Analyzing spikes from the onset to the peak. Clin Neurophysiol. 2016 Apr;127(4):2127-33. doi: 10.1016/j.clinph.2015.12.021. Epub 2016 Jan 12. — View Citation

Megevand P, Spinelli L, Genetti M, Brodbeck V, Momjian S, Schaller K, Michel CM, Vulliemoz S, Seeck M. Electric source imaging of interictal activity accurately localises the seizure onset zone. J Neurol Neurosurg Psychiatry. 2014 Jan;85(1):38-43. doi: 10.1136/jnnp-2013-305515. Epub 2013 Jul 30. — View Citation

Mouthaan BE, Rados M, Barsi P, Boon P, Carmichael DW, Carrette E, Craiu D, Cross JH, Diehl B, Dimova P, Fabo D, Francione S, Gaskin V, Gil-Nagel A, Grigoreva E, Guekht A, Hirsch E, Hecimovic H, Helmstaedter C, Jung J, Kalviainen R, Kelemen A, Kimiskidis V, Kobulashvili T, Krsek P, Kuchukhidze G, Larsson PG, Leitinger M, Lossius MI, Luzin R, Malmgren K, Mameniskiene R, Marusic P, Metin B, Ozkara C, Pecina H, Quesada CM, Rugg-Gunn F, Rydenhag B, Ryvlin P, Scholly J, Seeck M, Staack AM, Steinhoff BJ, Stepanov V, Tarta-Arsene O, Trinka E, Uzan M, Vogt VL, Vos SB, Vulliemoz S, Huiskamp G, Leijten FS, Van Eijsden P, Braun KP; E-PILEPSY consortium. Current use of imaging and electromagnetic source localization procedures in epilepsy surgery centers across Europe. Epilepsia. 2016 May;57(5):770-6. doi: 10.1111/epi.13347. Epub 2016 Mar 25. — View Citation

Rikir E, Koessler L, Gavaret M, Bartolomei F, Colnat-Coulbois S, Vignal JP, Vespignani H, Ramantani G, Maillard LG. Electrical source imaging in cortical malformation-related epilepsy: a prospective EEG-SEEG concordance study. Epilepsia. 2014 Jun;55(6):918-32. doi: 10.1111/epi.12591. Epub 2014 Apr 4. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary The Sensitivity and Specificity of automated ESI in presurgical evaluation. For determining the the accuracy (sensitivity and specificity) of automated ESI, one year outcome after the operation will be calculated based on the defined criteria.
True Positive (TP): source is in the same sub-lobar region as the resection, seizure-free outcome
False Positive (FP): source is in the same sub-lobar region as the resection, not seizure-free outcome
True Negative (TN): source outside the sub-lobar region that was resected, not seizure-free outcome
False Negative (FN): source outside the sub-lobar region that was resected, seizure-free outcome.
2 Years
Primary the clinical utility of ESI in management of the patient with medically refractory epilepsy For determining the clinical utility, the percentage of patients in whom automated ESI change decision on patients management will be calculated. 2 years
See also
  Status Clinical Trial Phase
Recruiting NCT05583916 - Same Day Discharge for Video-Assisted Thoracoscopic Surgery (VATS) Lung Surgery N/A
Completed NCT04448041 - CRANE Feasibility Study: Nutritional Intervention for Patients Undergoing Cancer Surgery in Low- and Middle-Income Countries
Completed NCT03213314 - HepaT1ca: Quantifying Liver Health in Surgical Candidates for Liver Malignancies N/A
Enrolling by invitation NCT05534490 - Surgery and Functionality in Older Adults N/A
Recruiting NCT04792983 - Cognition and the Immunology of Postoperative Outcomes
Terminated NCT04612491 - Pre-operative Consultation on Patient Anxiety and First-time Mohs Micrographic Surgery
Recruiting NCT06397287 - PROM Project Urology
Recruiting NCT04444544 - Quality of Life and High-Risk Abdominal Cancer Surgery
Completed NCT04204785 - Noise in the OR at Induction: Patient and Anesthesiologists Perceptions N/A
Completed NCT03432429 - Real Time Tissue Characterisation Using Mass Spectrometry REI-EXCISE iKnife Study
Completed NCT04176822 - Designing Animated Movie for Preoperative Period N/A
Recruiting NCT05370404 - Prescribing vs. Recommending Over-The-Counter (PROTECT) Analgesics for Patients With Postoperative Pain: N/A
Not yet recruiting NCT05467319 - Ferric Derisomaltose/Iron Isomaltoside and Outcomes in the Recovery of Gynecologic Oncology ERAS Phase 3
Recruiting NCT04602429 - Children's Acute Surgical Abdomen Programme
Completed NCT03124901 - Accuracy of Noninvasive Pulse Oximeter Measurement of Hemoglobin for Rainbow DCI Sensor N/A
Completed NCT04595695 - The Effect of Clear Masks in Improving Patient Relationships N/A
Recruiting NCT06103136 - Maestro 1.0 Post-Market Registry
Completed NCT05346588 - THRIVE Feasibility Trial Phase 3
Completed NCT04059328 - Novel Surgical Checklists for Gynecologic Laparoscopy in Haiti
Recruiting NCT03697278 - Monitoring Postoperative Patient-controlled Analgesia (PCA) N/A