Clinical Trials Logo

Spinal Fractures clinical trials

View clinical trials related to Spinal Fractures.

Filter by:

NCT ID: NCT02536898 Completed - Hip Fracture Clinical Trials

Norwegian Capture the Fracture Initiative

NoFRACT
Start date: May 2015
Phase: N/A
Study type: Interventional

The main aim is to assess the effectiveness of introducing a standardized intervention program for treatment of patients with a fragility fracture as measured by changes in the fracture rates and the mortality.

NCT ID: NCT02514993 Completed - Clinical trials for Thoracic Spine Fracture

The Unstable Thoracic Cage Injury

Start date: January 2003
Phase: N/A
Study type: Observational

- Analysis of patient data and computed tomography scan of polytraumatized patients thoracic spine fractures - A concomitant sternal fracture was identified an indicator for an unstable thoracic spine fracture

NCT ID: NCT02461810 Completed - Osteoporosis Clinical Trials

Prospective Comparative Study to Compare Safety and Effectiveness of Two Vertebral Compression Fracture Reduction Techniques

SAKOS
Start date: April 2015
Phase: N/A
Study type: Interventional

The purpose of this study is to compare the safety and effectiveness of the SpineJack® with the Kyphx Xpander® Inflatable Bone Tamp and support a non-inferiority finding for the use of SpineJack® VCF treatment system versus Balloon Kyphoplasty.

NCT ID: NCT02432495 Completed - Spinal Fractures Clinical Trials

Anterior Screw Fixation Versus Halo Immobilization of Type II Odontoid Fractures in Geriatric Patients With Increased Anesthesia Risk

Start date: April 2008
Phase: N/A
Study type: Observational

The management of type II odontoid fractures in geriatric trauma victims remains a source of substantial controversy. The purpose of this study was to compare anterior screw fixation with halo-vest-immobilization in patients with type II odontoid fractures.

NCT ID: NCT02252185 Completed - Spinal Stenosis Clinical Trials

A Clinical Study of a Spine Fusion System in Vertebral Body Fusion Surgery

Start date: July 2014
Phase: N/A
Study type: Interventional

The primary objective of this study is to demonstrate that the efficacy and safety of Spine fusion system manufactured in China is no inferior than imported product.

NCT ID: NCT02234414 Completed - Clinical trials for Postmenopausal Osteoporosis

Epidemiology, Identification Rate and Treatment Penetration of Osteoporotic Vertebral Fractures in Switzerland

SwOF
Start date: February 2009
Phase: N/A
Study type: Observational

In Switzerland, the prevalence of vertebral fractures in community- dwelling women is unknown and the published data from the Swiss hospitals statistics represent only the tip of the iceberg. In addition, the percentages of women correctly identified with vertebral fractures due to osteoporosis and the treatment rate of these women with a drug proven to reduce the risk of further fractures are unknown. Furthermore, it is not known whether the prevalence of vertebral fractures differs between urban and rural areas or between mountain areas and plain country, e.g. due to possible differences in sun exposure (vitamin D production) and/ or in physical activity and/ or dietary habits. Clinical signs and symptoms leading to the suspicion of vertebral fracture(s) lack either sensitivity (wall-occiput distance) or specificity (rib-pelvis distance). Whether a combination of both would improve sensitivity and specificity is unknown. The gold standard for the diagnosis of vertebral fracture relies on antero-posterior and lateral X-Rays of the thoracic and lumbar spine. Despite standardization of X-Ray readings, a retrospective study of hospitalized elderly patients has shown that as many as 50% of the radiographic reports failed to note the presence of moderate to severe vertebral fractures. In a primary care setting, fewer than 2% of the women received diagnoses of osteoporosis or vertebral fracture, although expected prevalence is 20% to 30% and appropriate drug treatment was offered to only 36% of the diagnosed patients. The recent availability of software for vertebral fracture assessment (VFA) coupled to DXA measurements allows for the detection of vertebral deformities, which is critical for management of osteoporosis, as the existence of such deformities substantially increases the risk of subsequent fracture. Recently published results show that VFA allows the diagnosis of a vertebral fracture. The sensitivity of VFA for detection of vertebral fractures compared to expert radiologist reading of X-ray is excellent for grade 2 and 3 fractures, ranging between 90-94%.

NCT ID: NCT02131571 Completed - Vertebral Fractures Clinical Trials

Prevalence of Vertebral Fractures in HIV Infected Patients Older Than 50 Years

FractaVIH
Start date: June 30, 2014
Phase:
Study type: Observational

Prospective cohort study to determine the prevalence of vertebral fractures in HIV infected patients older than 50 years.

NCT ID: NCT01963039 Completed - Osteoporosis Clinical Trials

A Trial of Vertebroplasty for Painful Chronic Osteoporotic Vertebral Fractures (Vertos V)

VERTOSV
Start date: May 2013
Phase: N/A
Study type: Interventional

Background The standard care in patients with a painful osteoporotic vertebral compression fracture (VCF) is conservative therapy. Percutaneous vertebroplasty (PV), a minimally invasive technique, is a relatively new treatment option. Recent randomized controlled trials (RCT) provide conflicting results: two sham-controlled studies showed no benefit of PV while an unmasked but controlled RCT (VERTOS II) found effective pain relief at acceptable costs in patients with acute VCFs. A still ongoing masked RCT (VERTOS IV) focuses on acute VCFs defined as ≤ 6 weeks. VERTOS III focused on conservative treatment and found that half of patients still had disabling pain after 3 months or longer. These patients with sustained pain after 3 months may benefit from PV. Objective To compare pain relief after PV with a sham intervention in selected patients with a chronic osteoporotic VCF ( three months or longer) using the same strict inclusion criteria as in VERTOS II an IV. Secondary outcome measures are back pain related disability and quality of life. Methods The VERTOS V study is a prospective RCT with pain relief as primary endpoint. Inclusion criteria are a VCF of thoracic level 5 or lower with focal tenderness at fracture level, assessed by an internist on physical examination and a Visual Analogue Scale (VAS) score ≥ 5 for three months or longer, decreased bone density defined as T score ≤ -1 and age 50 years or older. 94 patients will be included, 47 in each arm. Crossovers are not allowed. Follow-up is at regular intervals during one year period with VAS score for pain as primary endpoint. Secondary endpoints are back pain related disability and quality of life measured with the Quality of Life Questionnaire of the European Foundation for Osteoporosis and physical function measured with the Roland Morris Disability questionnaire. Conclusion Vertos V is a methodologically sound masked randomised sham controlled trial of vertebroplasty in patients with sustained pain 3 months or longer after a vertebral compression fracture.

NCT ID: NCT01847898 Completed - Clinical trials for Vertebral Body Fractures

Study on the Treatment of Osteoporotic Vertebral Fractures Using Vertebral Body Stenting

Start date: September 1, 2009
Phase: Phase 4
Study type: Interventional

This is a randomized, controlled study to document and evaluate the clinical performance of the Vertebral Body Stenting (VBS) System in osteoporotic fractures of the thoracic and lumbar spine. The randomized, controlled trial (RCT) will compare patients with VBS and Balloon Kyphoplasty.

NCT ID: NCT01839682 Completed - Osteoporosis Clinical Trials

Evaluation of Outcomes of DFine StabiliT Kyphoplasty in Vertebral Compression Fractures Due to Osteoporosis

Start date: June 2009
Phase: N/A
Study type: Observational

This post-market surveillance research project consists of data collection at specified time points using standard questionnaire instruments to compare pain level, mobility and function pre and post procedure using the D-Fine StabiliT® Vertebral Augmentation System and StabiliT® Bone Cement, an FDA approved product used in the standard treatment of vertebral compression fractures.