Clinical Trials Logo

Clinical Trial Summary

Transcatheter aortic valve replacement (TAVR) has become widely recognized as a minimally invasive approach for aortic valve replacement in patients with severe aortic stenosis. It has been proven to be a safe and effective option for patients who are at low, intermediate, and prohibitive risk for surgical valve replacement. One of the critical components of procedural success in a transfemoral approach is access site management, as vascular complications strongly correlate with adverse outcomes. When major vascular complications occur, there are higher rates of major bleeding, transfusions, and renal failure requiring dialysis, as well as a significantly higher rate of 30-day and 1-year mortality. In recent years, a "preclosure" technique has emerged as a common vascular closure approach using a Perclose Proglide system (Abbott Vascular), in which sutures are deployed before dilating the arterial access site. This allows for arterial closure after dilation to sizing up to larger bore access sheaths that accommodate valve delivery systems. The sutures are subsequently harvested and tightened to close the large bore arteriotomy site at the end of the case. It has been demonstrated that the use of two Perclose devices, or double Perclose closure, is an effective closure technique with a low rate of vascular complications. A large number of TAVR centers have adopted this method for large-bore vascular closure. In the past, there have been few investigations comparing the utilization of a single Perclose device compared to a double Perclose technique. There are numerous theoretical advantages to the use of a single device, which include decreased procedural cost and procedural time. The investigation aimed to determine if there are clinical benefits as well using the single Perclose approach.


Clinical Trial Description

SINGLE-CLOSURE (The utilization of Single versus double perclose devices for transfemoral aortIc valve replacement access site Closure) is an investigator-initiated, open-label, multicenter, randomized controlled trial. The study was approved by the local ethics committees of all participating centers, and each patient provided written informed consent for inclusion in the trial. Data management and analysis was performed by an independent data coordinating center, with oversight from a steering committee. The members of the steering committee had full access to the data and vouch for the accuracy and complete- ness of the data and the analyses. The data that support the findings of this study are available from the corresponding author on reasonable request. Patients scheduled to undergo transfemoral TAVR were considered for inclusion in the trial if they met all inclusion and none of the exclusion criteria. Inclusion criteria were an indication for TAVR as judged by the local heart team; selection of the transfemoral access route and a commercially available transcatheter aortic valve; and willingness to comply with protocol specified follow-up evaluations. Principal exclusion criteria were a vascular access site anatomy not suitable for percutaneous vascular closure and the occurrence of vascular access site complications before the TAVR procedure. Additional exclusion criteria were a known allergy or hypersensitivity to any VCD component; unstable active bleeding or bleeding diathesis or significant unman-ageable anemia; absence of computed tomographic data of the access site before the procedure; systemic infection or a local infection at or near the access site; life expectancy of <6 months because of noncardiac conditions; patients who cannot adhere to or complete the investigational protocol for any reason; pregnant or nursing patients; and participation in any other interventional trial. The primary end point of the trial was the rate of access site or access-related major and minor vascular complications defined according to the Valve Academic Research Consortium-3 criteria. The end point was assessed during index hospitalization. Relationship to the access site was deter- mined according to the site used for the large-bore vascular access sheath. Secondary end points included the rate of the primary end point at 30 days; components of the primary end point in-hospital and at 30 days; in-hospital and 30-day major and minor vascular complications; unplanned vascular surgery or use of endovascular stent or stent-graft or other endovascular interventions at the puncture site; in-hospital and 30-day access site- or access-related minor, major, and disabling or life threatening bleeding; need for blood transfusion for access site- or access-related bleeding or vascular complications; rate of VCD failure, defined as the failure of a closure device strategy to achieve hemostasis with the need for an alternative treatment (other than manual compression or adjunctive endovascular ballooning); in-hospital and 30-day all-cause death; in-hospital and 30-day death attributed to access site or access-related complications; need and number of additional unplanned VCDs; time to hemostasis, defined as the time from VCD application to complete hemostasis; and the length of postprocedural hospital stay. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06173115
Study type Interventional
Source Second Affiliated Hospital, School of Medicine, Zhejiang University
Contact XianBao Liu, PhD
Phone 13857173887
Email liuxb@zju.edu.cn
Status Recruiting
Phase N/A
Start date October 20, 2023
Completion date February 28, 2026

See also
  Status Clinical Trial Phase
Completed NCT01238497 - SOURCE XT REGISTRY
Recruiting NCT04029844 - Colibri Transcatheter Aortic Heart Valve System Study N/A
Recruiting NCT03280433 - Influence of EPICardial Adipose Tissue in HEART Diseases: EPICHEART Study N/A
Completed NCT05492383 - SAvvyWireâ„¢ EFficacy and SafEty in Transcatheter Aortic Valve Implantation Procedures (SAFE-TAVI) N/A
Active, not recruiting NCT03752866 - The CONFIDENCE Registry N/A
Completed NCT01651780 - Open-label, Randomized Trial in Patients Undergoing TAVR to Determine Safety & Efficacy of Bivalirudin vs UFH Phase 3
Recruiting NCT06136429 - A Prospective, Multicenter, Single-arm Study to Evaluate a Transcatheter Aortic Valve System Safety and Efficacy for the Treatment of Patients With Severe Aortic Stenosis N/A
Not yet recruiting NCT06015997 - Prevalence of ATTR Cardiac Amyloidosis in Patients Undergoing TAVR
Recruiting NCT03291925 - Primary Non-invasive Cardiac Computed Tomography Versus Routine Invasive Angiography Prior to TAVI N/A
Terminated NCT03004599 - Safety and Efficacy of SYM-SV/DS-002 in Patients With Severe Aortic Stenosis N/A
Recruiting NCT04076150 - Safety and Performance Study of the Optimum Transcatheter Aortic Valve N/A
Completed NCT01074658 - CoreValve Advance International Post Market Study N/A
Completed NCT02575768 - Myocardial Flow Reserve in Severe AS Without Obstructive Coronary Artery Disease N/A
Completed NCT01994330 - Severe Aortic Stenosis and Acquired Von Willebrand´s Disease: The Impact of Desmopressin in Valve-Replacement Surgery Phase 4
Completed NCT04286893 - Improved HRV, Inflammation Markers and Endothelial Function After TAVI
Not yet recruiting NCT06177392 - VARC-TAVI VALVE IMPLANTATION) N/A
Active, not recruiting NCT04206228 - Intravenous Iron Supplement for Iron Deficiency in Patients With Severe Aortic Stenosis Phase 2
Not yet recruiting NCT03788590 - Evaluate the Transcatheter Artificial Aortic Valve and Transcatheter Artificial Heart Values Delivery System N/A
Completed NCT01531374 - Safety and Efficacy Continued Access Study of the Medtronic CoreValve® System in the Treatment of Symptomatic Severe Aortic Stenosis in Very High Risk Subjects and High Risk Subjects Who Need Aortic Valve Replacement N/A
Recruiting NCT05493657 - Aspirin vs Clopidogrel After TAVR N/A