Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT05849831
Other study ID # 10597-30-4-2023
Secondary ID
Status Completed
Phase
First received
Last updated
Start date May 3, 2023
Est. completion date May 30, 2024

Study information

Verified date June 2024
Source Zagazig University
Contact n/a
Is FDA regulated No
Health authority
Study type Observational

Clinical Trial Summary

Sepsis-associated brain dysfunction (SABD)with increased intracranial pressure is a complex pathology that can lead to unfavourable outcome. Although direct measurement of intracranial pressure using an intra-ventricular catheter remains the gold standard, it is burdened with potential serious complications due to its invasiveness. Ultrasonic measurement of optic nerve sheath diameter (ONSD) is a non-invasive method for ICP monitoring. Screening for SABD is crucial for early diagnosis and management, measurement of ONSD can detect elevated intracranial pressure in septic patients. Intracranial hypertension in septic patients might be a sign of SABD. Using ONSD for SABD screening requires further research. So, we hypothesized that ONSD could be used as an objective screening tool to predict and early diagnose SABD in adult septic patients.


Description:

Sepsis is the most common complication in adult critically ill patients, and it has been become the leading cause of morbidity and mortality worldwide. The essential component of sepsis is the presence of an acute organ dysfunction. The brain is highly vulnerable to the inflammatory storm associated with infection and it may be the first organ to show signs of life-threatening organ dysfunction caused by infection. This brain dysfunction is known as "sepsis-associated encephalopathy (SAE)". Sepsis-associated brain dysfunction is considered the commonest type of encephalopathy seen in intensive care unit (ICU). it is defined as a life- threatening acute diffuse brain dysfunction due to infection outside the central nervous system (CNS) and is mostly caused by the inflammatory storm. It varies from delirium or confusion, seizure or focal neurological sign, and diffuse or multifocal neurological deficits, to stupor or coma with no other diagnoses describing the patient neurological status. SAE may occur in up to 70% of septic patients and it significantly increases mortality. It is a complex syndrome with unclear pathophysiology. The possible causes could include neuro-inflammation, excitotoxicity, impaired cerebral autoregulation, and cerebral ischemia. These Pathophysiological changes may lead to increase in the intracranial pressure (ICP) which may in turn decrease cerebral perfusion and lead to brain edema, brain damage and compromised the outcome of these patients. Therefore, early detection of increased ICP is of paramount importance for timely intervention and improved prognosis. However, direct invasive ICP monitoring is not routinely recommended in non-traumatic coma patients as well as septic patients either due to absence of intracranial infection or coagulopathy; so, a reliable non-invasive ICP monitoring method is highly recommended. Bedside ultrasonographic assessment of the optic nerve sheath diameter (ONSD) offers a satisfactory non-invasive ICP monitoring test and is documented as a sensitive and specific predictor of cerebral edema and is strongly correlated with both invasive ICP measurements and radiographic cerebral edema as diagnosed by CT scan or MRI. Considering that SAE is a diagnosis of exclusion as well as screening method for SAE is necessary for early diagnosis and timely management. We hypothesized that ONSD could have a role as an objective screening tool to predict and early diagnose ICP changes in septic patients.


Recruitment information / eligibility

Status Completed
Enrollment 89
Est. completion date May 30, 2024
Est. primary completion date May 30, 2024
Accepts healthy volunteers
Gender All
Age group 21 Years to 70 Years
Eligibility Inclusion Criteria: - Patient acceptance. - Age 21- 70 years old. - Patients diagnosed with sepsis For diagnosis of sepsis and septic shock, the third international definition and appropriate diagnostic criteria was used. Sepsis was defined as life-threatening organ dysfunction caused by a dysregulated host response to an infection, and it is suspected in an acutely deteriorating patient in whom there is clinical evidence or strong suspicion of infection. Septic shock was defined as the need for vasopressors or vasoactive medication to maintain a mean arterial blood pressure of 65 mmHg or higher after adequate fluid resuscitation, with the presence of a high lactate (>2 mmol/l). Exclusion Criteria: - Patient refusal. - Ocular wound - History of prior ocular trauma or surgery - Conjunctival edema or orbital edema - Vitreous hemorrhage - Central nervous system (CNS) infection - Cerebrovascular accident - Brain trauma - Any previous neurosurgical procedure

Study Design


Intervention

Diagnostic Test:
Ultrasound measurement of Optic nerve sheath diameter
Ocular ultrasonography will be performed by single skilled examiner with patients placed in supine position with closed eyes. A layer of ultrasound gel will be applied over the closed upper eyelid and the liner high frequency probe 7 - 12 MHz of SonoSite M-Turbo ultrasound machine is placed on temporal area of eyelid with the hand holding it resting on forehead of patient. ONSD is measured 3mm behind the globe in the transverse plane perpendicular to the optic nerve. For each eye one measurement will be made and the reported ONSD corresponds to the mean of the two values obtained for each patient. An average ONSD greater than 5 mm is considered abnormal and elevated intracranial pressure should be suspected. all enrolled subjects will be eligible for ONSD measurements, SOFA score calculation, as well as GCS assessment on daily basis for up to 10 consecutive days, until ICU discharge or death.

Locations

Country Name City State
Egypt Benha University Hospitals Banha Qalubiya
Egypt Zagazig University Hospitals Zagazig Sharkia

Sponsors (1)

Lead Sponsor Collaborator
Zagazig University

Country where clinical trial is conducted

Egypt, 

References & Publications (17)

3. Tong D, Wang S, Wang Y, et al. Sepsis-associated Encephalopathy In ICU Admissions: Prevalence, Early Risk of Death, and its Early Prevent and Control. Research Square; 2020. DOI: 10.21203/rs.3.rs-58687/v1.

Cammarata G, Ristagno G, Cammarata A, Mannanici G, Denaro C, Gullo A. Ocular ultrasound to detect intracranial hypertension in trauma patients. J Trauma. 2011 Sep;71(3):779-81. doi: 10.1097/TA.0b013e3182220673. — View Citation

Coopersmith CM, De Backer D, Deutschman CS, Ferrer R, Lat I, Machado FR, Martin GS, Martin-Loeches I, Nunnally ME, Antonelli M, Evans LE, Hellman J, Jog S, Kesecioglu J, Levy MM, Rhodes A. Surviving sepsis campaign: research priorities for sepsis and septic shock. Intensive Care Med. 2018 Sep;44(9):1400-1426. doi: 10.1007/s00134-018-5175-z. Epub 2018 Jul 3. — View Citation

Crippa IA, Subira C, Vincent JL, Fernandez RF, Hernandez SC, Cavicchi FZ, Creteur J, Taccone FS. Impaired cerebral autoregulation is associated with brain dysfunction in patients with sepsis. Crit Care. 2018 Dec 4;22(1):327. doi: 10.1186/s13054-018-2258-8. — View Citation

Czempik PF, Gasiorek J, Bak A, Krzych LJ. Ultrasonic Assessment of Optic Nerve Sheath Diameter in Patients at Risk of Sepsis-Associated Brain Dysfunction: A Preliminary Report. Int J Environ Res Public Health. 2020 May 22;17(10):3656. doi: 10.3390/ijerph17103656. — View Citation

Czempik PF, Pluta MP, Krzych LJ. Sepsis-Associated Brain Dysfunction: A Review of Current Literature. Int J Environ Res Public Health. 2020 Aug 12;17(16):5852. doi: 10.3390/ijerph17165852. — View Citation

Heming N, Mazeraud A, Verdonk F, Bozza FA, Chretien F, Sharshar T. Neuroanatomy of sepsis-associated encephalopathy. Crit Care. 2017 Mar 21;21(1):65. doi: 10.1186/s13054-017-1643-z. — View Citation

Major R, Girling S, Boyle A. Ultrasound measurement of optic nerve sheath diameter in patients with a clinical suspicion of raised intracranial pressure. Emerg Med J. 2011 Aug;28(8):679-81. doi: 10.1136/emj.2009.087353. Epub 2010 Aug 15. — View Citation

Pfister D, Schmidt B, Smielewski P, Siegemund M, Strebel SP, Ruegg S, Marsch SC, Pargger H, Steiner LA. Intracranial pressure in patients with sepsis. Acta Neurochir Suppl. 2008;102:71-5. doi: 10.1007/978-3-211-85578-2_14. — View Citation

Pfister D, Siegemund M, Dell-Kuster S, Smielewski P, Ruegg S, Strebel SP, Marsch SC, Pargger H, Steiner LA. Cerebral perfusion in sepsis-associated delirium. Crit Care. 2008;12(3):R63. doi: 10.1186/cc6891. Epub 2008 May 5. — View Citation

Qayyum H, Ramlakhan S. Can ocular ultrasound predict intracranial hypertension? A pilot diagnostic accuracy evaluation in a UK emergency department. Eur J Emerg Med. 2013 Apr;20(2):91-7. doi: 10.1097/MEJ.0b013e32835105c8. — View Citation

Rajajee V, Vanaman M, Fletcher JJ, Jacobs TL. Optic nerve ultrasound for the detection of raised intracranial pressure. Neurocrit Care. 2011 Dec;15(3):506-15. doi: 10.1007/s12028-011-9606-8. — View Citation

Sekhon MS, Griesdale DE, Robba C, McGlashan N, Needham E, Walland K, Shook AC, Smielewski P, Czosnyka M, Gupta AK, Menon DK. Optic nerve sheath diameter on computed tomography is correlated with simultaneously measured intracranial pressure in patients with severe traumatic brain injury. Intensive Care Med. 2014 Sep;40(9):1267-74. doi: 10.1007/s00134-014-3392-7. Epub 2014 Jul 18. Erratum In: Intensive Care Med. 2015 Jan;41(1):177. Intensive Care Med. 2015 Jan;41(1):177. — View Citation

Shirodkar CG, Rao SM, Mutkule DP, Harde YR, Venkategowda PM, Mahesh MU. Optic nerve sheath diameter as a marker for evaluation and prognostication of intracranial pressure in Indian patients: An observational study. Indian J Crit Care Med. 2014 Nov;18(11):728-34. doi: 10.4103/0972-5229.144015. — View Citation

Singer M, Deutschman CS, Seymour CW, Shankar-Hari M, Annane D, Bauer M, Bellomo R, Bernard GR, Chiche JD, Coopersmith CM, Hotchkiss RS, Levy MM, Marshall JC, Martin GS, Opal SM, Rubenfeld GD, van der Poll T, Vincent JL, Angus DC. The Third International Consensus Definitions for Sepsis and Septic Shock (Sepsis-3). JAMA. 2016 Feb 23;315(8):801-10. doi: 10.1001/jama.2016.0287. — View Citation

Strumwasser A, Kwan RO, Yeung L, Miraflor E, Ereso A, Castro-Moure F, Patel A, Sadjadi J, Victorino GP. Sonographic optic nerve sheath diameter as an estimate of intracranial pressure in adult trauma. J Surg Res. 2011 Oct;170(2):265-71. doi: 10.1016/j.jss.2011.03.009. Epub 2011 Apr 1. — View Citation

Yang Z, Qin C, Zhang S, Liu S, Sun T. Bedside ultrasound measurement of optic nerve sheath diameter in patients with sepsis: a prospective observational study. Crit Care. 2020 May 18;24(1):235. doi: 10.1186/s13054-020-02959-7. No abstract available. — View Citation

* Note: There are 17 references in allClick here to view all references

Outcome

Type Measure Description Time frame Safety issue
Primary correlation between ONSD measurements and the occurrence of SAE ultrasonographic measurement of optic nerve sheath diameter (ONSD) will be performed and recorded on daily basis for up to 10 consecutive days, until ICU discharge or death then we will compare the ONSD measurements of non-SAE patients to those of SAE patients. 10 days
Secondary the correlation between ONSD measurements and the ICU mortality of critically ill patients with sepsis ultrasonographic measurement of optic nerve sheath diameter (ONSD) will be performed and recorded on daily basis for up to 10 consecutive days, until ICU discharge or death then we will compare the ONSD measurements of ICU survivors to those of dead patients during the ICU stay. 30 days
See also
  Status Clinical Trial Phase
Active, not recruiting NCT05095324 - The Biomarker Prediction Model of Septic Risk in Infected Patients
Completed NCT02714595 - Study of Cefiderocol (S-649266) or Best Available Therapy for the Treatment of Severe Infections Caused by Carbapenem-resistant Gram-negative Pathogens Phase 3
Completed NCT03644030 - Phase Angle, Lean Body Mass Index and Tissue Edema and Immediate Outcome of Cardiac Surgery Patients
Completed NCT02867267 - The Efficacy and Safety of Ta1 for Sepsis Phase 3
Completed NCT04804306 - Sepsis Post Market Clinical Utility Simple Endpoint Study - HUMC
Recruiting NCT05578196 - Fecal Microbial Transplantation in Critically Ill Patients With Severe Infections. N/A
Terminated NCT04117568 - The Role of Emergency Neutrophils and Glycans in Postoperative and Septic Patients
Completed NCT03550794 - Thiamine as a Renal Protective Agent in Septic Shock Phase 2
Completed NCT04332861 - Evaluation of Infection in Obstructing Urolithiasis
Completed NCT04227652 - Control of Fever in Septic Patients N/A
Enrolling by invitation NCT05052203 - Researching the Effects of Sepsis on Quality Of Life, Vitality, Epigenome and Gene Expression During RecoverY From Sepsis
Terminated NCT03335124 - The Effect of Vitamin C, Thiamine and Hydrocortisone on Clinical Course and Outcome in Patients With Severe Sepsis and Septic Shock Phase 4
Recruiting NCT04005001 - Machine Learning Sepsis Alert Notification Using Clinical Data Phase 2
Completed NCT03258684 - Hydrocortisone, Vitamin C, and Thiamine for the Treatment of Sepsis and Septic Shock N/A
Recruiting NCT05217836 - Iron Metabolism Disorders in Patients With Sepsis or Septic Shock.
Completed NCT05018546 - Safety and Efficacy of Different Irrigation System in Retrograde Intrarenal Surgery N/A
Completed NCT03295825 - Heparin Binding Protein in Early Sepsis Diagnosis N/A
Not yet recruiting NCT06045130 - PUFAs in Preterm Infants
Not yet recruiting NCT05361135 - 18-fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in S. Aureus Bacteraemia N/A
Not yet recruiting NCT05443854 - Impact of Aminoglycosides-based Antibiotics Combination and Protective Isolation on Outcomes in Critically-ill Neutropenic Patients With Sepsis: (Combination-Lock01) Phase 3