Clinical Trial Summary

The aim of this study is to assess whether changes in the plethysmography variability index, during a tidal volume challenge, can reliably detect simultaneous changes in arterial blood pressure pulsatility, in patients hospitalized in intensive care unit. If results will be positive, this will allow the test to be performed even in the absence of an invasive arterial catheter.


Description:

Among patients in a state of shock one of the first treatments is volume expansion, consisting in a fast intravenous injection of crystalloid or colloid solutions in order to increase cardiac preload and consequently cardiac output. However, this augmentation of the cardiac output happens only in half of the patients.To avoid ineffective fluid administration several tests have been developed. One of these tests is called the "tidal volume challenge" (TVC). It consists of transiently increasing for 1 minute the volume of air inhaled with each breath, in mechanically ventilated patients, and then evaluating whether this change impacts the pulsatility of the arterial blood pressure, detected by an arterial catheter. This test seems reliable, but it requires an arterial catheter to be in place. It has been suggested in previous studies that pulsatility of blood pressure can be estimated by the pulsatility of the plethysmography signal ("plethysmography variability index"), obtained from the oxygen saturation signal that's measured in all intensive care patients. The advantage is that this measurement only requires a sensor placed at the end of a finger, on the earlobe or on the forehead. The aim of the study is to assess whether changes in the plethysmography variability index (PVI) during a TVC can reliably detect simultaneous changes in blood pressure pulsatility. This study will include patients hospitalized in intensive care unit, mechanically ventilated, in whom physicians have decided to perform a TVC as common practice. Changes, occurred during this test, in arterial blood pressure pulsatility and in plethysmography pulsatility index will be measured and compared. If results will show that changes in PVI during TVC are reliable for measuring blood pressure pulsatility changes during this test, this will allow the test to be used even in the absence of an arterial catheter.


Recruitment information / eligibility

Status Recruiting
Enrollment 44
Est. completion date November 2022
Est. primary completion date November 2022
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: - patients hospitalized in intensive care unit - physicians' decision to perform a tidal volume challenge - hemodynamic monitoring with a calibrated pulse contour analysis device (PICCO2) in place - monitoring of oxygen saturation with Masimo SET - mechanical ventilation with tidal volume of 6 ml/kg on ideal body weight Exclusion Criteria: - thoracic drainage - patient under judicial protection

Study Design


Related Conditions & MeSH terms


Locations

Country Name City State
France Service de médecine intensive-réanimation, Hôpital de Bicêtre Le Kremlin-Bicêtre

Sponsors (1)

Lead Sponsor Collaborator
Bicetre Hospital

Country where clinical trial is conducted

France, 

References & Publications (15)

Alvarado Sánchez JI, Caicedo Ruiz JD, Diaztagle Fernández JJ, Amaya Zuñiga WF, Ospina-Tascón GA, Cruz Martínez LE. Predictors of fluid responsiveness in critically ill patients mechanically ventilated at low tidal volumes: systematic review and meta-analysis. Ann Intensive Care. 2021 Feb 8;11(1):28. doi: 10.1186/s13613-021-00817-5. Review. — View Citation

Cannesson M, Attof Y, Rosamel P, Desebbe O, Joseph P, Metton O, Bastien O, Lehot JJ. Respiratory variations in pulse oximetry plethysmographic waveform amplitude to predict fluid responsiveness in the operating room. Anesthesiology. 2007 Jun;106(6):1105-11. — View Citation

Cannesson M, Desebbe O, Hachemi M, Jacques D, Bastien O, Lehot JJ. Respiratory variations in pulse oximeter waveform amplitude are influenced by venous return in mechanically ventilated patients under general anaesthesia. Eur J Anaesthesiol. 2007 Mar;24(3):245-51. Epub 2006 Oct 23. — View Citation

Cannesson M, Desebbe O, Rosamel P, Delannoy B, Robin J, Bastien O, Lehot JJ. Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre. Br J Anaesth. 2008 Aug;101(2):200-6. doi: 10.1093/bja/aen133. Epub 2008 Jun 2. — View Citation

Coeckelenbergh S, Delaporte A, Ghoundiwal D, Bidgoli J, Fils JF, Schmartz D, Van der Linden P. Pleth variability index versus pulse pressure variation for intraoperative goal-directed fluid therapy in patients undergoing low-to-moderate risk abdominal surgery: a randomized controlled trial. BMC Anesthesiol. 2019 Mar 9;19(1):34. doi: 10.1186/s12871-019-0707-9. — View Citation

Feissel M, Teboul JL, Merlani P, Badie J, Faller JP, Bendjelid K. Plethysmographic dynamic indices predict fluid responsiveness in septic ventilated patients. Intensive Care Med. 2007 Jun;33(6):993-9. Epub 2007 Mar 29. — View Citation

Landsverk SA, Hoiseth LO, Kvandal P, Hisdal J, Skare O, Kirkeboen KA. Poor agreement between respiratory variations in pulse oximetry photoplethysmographic waveform amplitude and pulse pressure in intensive care unit patients. Anesthesiology. 2008 Nov;109(5):849-55. doi: 10.1097/ALN.0b013e3181895f9f. — View Citation

Liu T, Xu C, Wang M, Niu Z, Qi D. Reliability of pleth variability index in predicting preload responsiveness of mechanically ventilated patients under various conditions: a systematic review and meta-analysis. BMC Anesthesiol. 2019 May 8;19(1):67. doi: 10.1186/s12871-019-0744-4. — View Citation

Marik PE, Monnet X, Teboul JL. Hemodynamic parameters to guide fluid therapy. Ann Intensive Care. 2011 Mar 21;1(1):1. doi: 10.1186/2110-5820-1-1. — View Citation

Monnet X, Guérin L, Jozwiak M, Bataille A, Julien F, Richard C, Teboul JL. Pleth variability index is a weak predictor of fluid responsiveness in patients receiving norepinephrine. Br J Anaesth. 2013 Feb;110(2):207-13. doi: 10.1093/bja/aes373. Epub 2012 Oct 26. — View Citation

Myatra SN, Prabu NR, Divatia JV, Monnet X, Kulkarni AP, Teboul JL. The Changes in Pulse Pressure Variation or Stroke Volume Variation After a "Tidal Volume Challenge" Reliably Predict Fluid Responsiveness During Low Tidal Volume Ventilation. Crit Care Med. 2017 Mar;45(3):415-421. doi: 10.1097/CCM.0000000000002183. — View Citation

Natalini G, Rosano A, Taranto M, Faggian B, Vittorielli E, Bernardini A. Arterial versus plethysmographic dynamic indices to test responsiveness for testing fluid administration in hypotensive patients: a clinical trial. Anesth Analg. 2006 Dec;103(6):1478-84. — View Citation

National Heart, Lung, and Blood Institute Acute Respiratory Distress Syndrome (ARDS) Clinical Trials Network, Wiedemann HP, Wheeler AP, Bernard GR, Thompson BT, Hayden D, deBoisblanc B, Connors AF Jr, Hite RD, Harabin AL. Comparison of two fluid-management strategies in acute lung injury. N Engl J Med. 2006 Jun 15;354(24):2564-75. Epub 2006 May 21. — View Citation

Taccheri T, Gavelli F, Teboul JL, Shi R, Monnet X. Do changes in pulse pressure variation and inferior vena cava distensibility during passive leg raising and tidal volume challenge detect preload responsiveness in case of low tidal volume ventilation? Crit Care. 2021 Mar 18;25(1):110. doi: 10.1186/s13054-021-03515-7. — View Citation

Vincent JL, Sakr Y, Sprung CL, Ranieri VM, Reinhart K, Gerlach H, Moreno R, Carlet J, Le Gall JR, Payen D; Sepsis Occurrence in Acutely Ill Patients Investigators. Sepsis in European intensive care units: results of the SOAP study. Crit Care Med. 2006 Feb;34(2):344-53. — View Citation

* Note: There are 15 references in allClick here to view all references

Outcome

Type Measure Description Time frame Safety issue
Primary Reliability of PVI changes in diagnosing preload responsiveness during TVC The primary objective is to assess the reliability of PVI changes induced by a tidal volume challenge test in diagnosing a preload responsiveness state in adult ICU patients. TVC is performed in 1 minute
Secondary Reliability of PVI absolute values to diagnose preload responsiveness Secondary objective is to test the reliability of absolute values of PVI to diagnose a preload responsiveness state in adult intensive care patients. TVC is performed in 1 minute
Secondary Evaluation of PVI changes during TVC according to sensor position Third objective is to compare the value of changes in PVI induced by a tidal volume challenge test to diagnose a preload responsiveness state according to the location of the plethysmographic measurement (finger, earlobe, forehead). TVC is performed in 1 minute
Secondary Comparison of PPV and PVI changes during PLR test or volume expansion Forth objective is to compare the changes in pulse pressure variation (PPV) and PVI during a passive leg raising test (PLR) and a volume expansion, if applicable. PLR is performed in 1 minute
See also
  Status Clinical Trial Phase
Active, not recruiting NCT05095324 - The Biomarker Prediction Model of Septic Risk in Infected Patients
Completed NCT02714595 - Study of Cefiderocol (S-649266) or Best Available Therapy for the Treatment of Severe Infections Caused by Carbapenem-resistant Gram-negative Pathogens Phase 3
Completed NCT03644030 - Phase Angle, Lean Body Mass Index and Tissue Edema and Immediate Outcome of Cardiac Surgery Patients
Completed NCT02867267 - The Efficacy and Safety of Ta1 for Sepsis Phase 3
Completed NCT04804306 - Sepsis Post Market Clinical Utility Simple Endpoint Study - HUMC
Recruiting NCT05578196 - Fecal Microbial Transplantation in Critically Ill Patients With Severe Infections. N/A
Terminated NCT04117568 - The Role of Emergency Neutrophils and Glycans in Postoperative and Septic Patients
Completed NCT03550794 - Thiamine as a Renal Protective Agent in Septic Shock Phase 2
Completed NCT04332861 - Evaluation of Infection in Obstructing Urolithiasis
Completed NCT04227652 - Control of Fever in Septic Patients N/A
Enrolling by invitation NCT05052203 - Researching the Effects of Sepsis on Quality Of Life, Vitality, Epigenome and Gene Expression During RecoverY From Sepsis
Terminated NCT03335124 - The Effect of Vitamin C, Thiamine and Hydrocortisone on Clinical Course and Outcome in Patients With Severe Sepsis and Septic Shock Phase 4
Recruiting NCT04005001 - Machine Learning Sepsis Alert Notification Using Clinical Data Phase 2
Completed NCT03258684 - Hydrocortisone, Vitamin C, and Thiamine for the Treatment of Sepsis and Septic Shock N/A
Recruiting NCT05217836 - Iron Metabolism Disorders in Patients With Sepsis or Septic Shock.
Completed NCT05018546 - Safety and Efficacy of Different Irrigation System in Retrograde Intrarenal Surgery N/A
Completed NCT03295825 - Heparin Binding Protein in Early Sepsis Diagnosis N/A
Not yet recruiting NCT06045130 - PUFAs in Preterm Infants
Not yet recruiting NCT05361135 - 18-fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in S. Aureus Bacteraemia N/A
Not yet recruiting NCT05443854 - Impact of Aminoglycosides-based Antibiotics Combination and Protective Isolation on Outcomes in Critically-ill Neutropenic Patients With Sepsis: (Combination-Lock01) Phase 3