Clinical Trials Logo

Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT05191212
Other study ID # 2021/455
Secondary ID
Status Recruiting
Phase N/A
First received
Last updated
Start date July 13, 2021
Est. completion date March 15, 2023

Study information

Verified date December 2022
Source Bakirkoy Dr. Sadi Konuk Research and Training Hospital
Contact Gökhan Demirayak, Assoc. Prof.
Phone +90 5323077899
Email dmryk.g@gmail.com
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

Purpose of the study Primary treatment of clinical early stage endometrial cancer is total hysterectomy, bilateral salpingo-oophorectomy, and lymph node dissection for staging. It was stated in the National Comprehensive Cancer Network (NCCN) guideline that sentinel lymph node biopsy can be performed as an alternative to systematic lymphadenectomy, including high-risk endometrial cancer histologies (2). In a study, the rate of bilateral sentinel lymph node detection in sentinel lymph node mapping using the cervical injection technique of indocyanine green was found to be 73.3%. After re-injection of cervical indocyanine green in patients whose sentinel lymph node could not be detected, the rate of detection of bilateral sentinel lymph nodes increased to 94.5% (4). However, repeated cervical injection causes a waste of time. In our clinic, sentinel lymph node mapping method is applied using indocyanine green for lymph node dissection for staging purposes, since the robotic system has a fluorescent imaging system in patients operated with robotic surgery for endometrial cancer. In accordance with the literature, our bilateral sentinel lymph node detection rate was 75%. During cervical indocyanine green injection in our last 6 patients, the lymphatic channels in the pelvic region were followed simultaneously with the injection and indocyanine injection was performed until the channels were seen transperitoneally. Bilateral lymphatic channels were seen in all of these patients, and sentinel lymph nodes were found bilaterally in all of them. The aim of the planned study is to compare the traditional cervical indocyanine green injection and indocyanine injection until the lymphatic channels are visualized for bilateral detection of sentinel lymph nodes in patients with clinical early stage endometrial cancer. Material-Method The number of patients planned to be included in the study was calculated as 24 patients in both groups, with an alpha error value of 5% and a statistical power above 80% when the bilateral sentinel lymph node detection rate was 75% in the traditional method and 99% in the study group (SPH analytics 2021).


Description:

Purpose of the study Endometrial cancer is the most common cancer of the female genital tract. In the USA, 65,620 new cases were detected in 2020, and 12,590 deaths occurred. Primary treatment of clinical early stage endometrial cancer is total hysterectomy, bilateral salpingo-oophorectomy, and lymph node dissection for staging. It was stated in the National Comprehensive Cancer Network (NCCN) guideline that sentinel lymph node biopsy can be performed as an alternative to systematic lymphadenectomy, including high-risk endometrial cancer histologies. Although dyes such as methylene blue or isosulfan blue and radioactive substances such as technetium-99 can be used in sentinel lymph node biopsy, fluorescent imaging systems using indocyanine green have recently been widely used due to high detection rates. Side-specific pelvic lymphadenectomy should be performed in the region where no sentinel lymph node can be detected. This increases the duration and difficulty of the operation and may cause morbidities such as leg edema and lymphocele. In a study, the rate of bilateral sentinel lymph node detection in sentinel lymph node mapping using the cervical injection technique of indocyanine green was found to be 73.3%. After re-injection of cervical indocyanine green in patients whose sentinel lymph node could not be detected, the rate of detection of bilateral sentinel lymph nodes increased to 94.5%. However, repeated cervical injection causes a waste of time. In investigator's clinic, sentinel lymph node mapping method is applied using indocyanine green for lymph node dissection for staging purposes, since the robotic system has a fluorescent imaging system in patients operated with robotic surgery for endometrial cancer. In accordance with the literature, the investigator's bilateral sentinel lymph node detection rate was 75%. During cervical indocyanine green injection in the last 6 patients of the investigators, the lymphatic channels in the pelvic region were followed simultaneously with the injection and indocyanine injection was performed until the channels were seen transperitoneally. Bilateral lymphatic channels were seen in all of these patients, and sentinel lymph nodes were found bilaterally in all of them. The aim of the planned study is to compare the traditional cervical indocyanine green injection and indocyanine green injection until the lymphatic channels are visualized for bilateral detection of sentinel lymph nodes in patients with clinical early stage endometrial cancer. Material-Method Among the patients who applied to the Health Sciences University, Bakırköy Dr Sadi Konuk Training and Research Hospital, Gynecological Oncology clinic due to endometrial cancer and were found to be in the clinical early stage as a result of imaging, those suitable for robotic surgery will be included in the study. An informed consent form will be signed by the patients who agree to participate in the study. Procedure: In this technic, 25 mg of indocyanine green powder dissolved in 10 cc of sterile water. A 10 mL sterile syringe is filled with 2 cc of ICG and diluted with 8 cc of sterile water, obtaining a total of 10 cc solution with a ICG final concentration of a 0,5 mg/mL. After docking of the Da Vinci Xi Surgical System (Intuitive Surgical, Sunnyvale, CA, USA), firstly, each 1 cc volume of the ICG is injected to the deep stroma (1 cm of depth) and submucosa (1 mm depth) at 9 o'clock position into the cervix by using 22-gauge spinal needle. While the injection is performing, the surgeon watches real-time appearance of ICG in the lymphatic channel transperitoneally from the console using fire-fly mode of the robotic system. If the appearance of ICG can not been observed, additional 1 cc volume of ICG is injected to the near side of first injection site of deep stroma and submucosa respectively until visualization of real-time appearance of ICG in lymphatic channel. The same procedure is performed contralateral site, at 3 o'clock position of the cervix. Then retroperitoneum is opened. Fire-fly mode of the robot is activated and sentinel nodes are removed gently All these procedures were performed by two collaborating surgeons. Demographic data of the patients such as age, parity, body-mass index, systemic diseases, tumor histology, presence of lymphovascular invasion, disease data such as tumor diameter, operation time, amount of bleeding, bilateral or unilateral detection rates of sentinel lymph nodes, if any, intraoperative and operative results such as postoperative complications, whether blood product replacement is performed, length of stay in hospital, and whether there is a need for postoperative intensive care unit will be recorded. Statistical View The number of patients planned to be included in the study was calculated as 24 patients in both groups, with an alpha error value of 5% and a statistical power above 80% when the bilateral sentinel lymph node detection rate was 75% in the traditional method and 99% in the study group (SPH analytics 2021). For continuous variables, the Mann-Whitney U test will be compared if appropriate, and for categorical variables, the frequency distribution will be compared with Chi-square or Fisher's exact test. Univariate and multivariate Cox proportional hazard ratio (HR) analyzes will be performed to identify independent prognostic factors. For all cases, a p value < 0.05 would be considered statistically significant. SPSS version 25.0 (IBM, Armonk, NY, USA) will be used for statistical analysis. Inclusion criteria Patients with clinical stage 1-2 endometrial cancer ASA 1-3 patients Exclusion criteria from the study Patients with clinical stage 3-4 endometrial cancer Patients who are not suitable for robotic surgery due to their comorbidities (such as glaucoma, COPD, asthma) ASA 4-5 patients


Recruitment information / eligibility

Status Recruiting
Enrollment 48
Est. completion date March 15, 2023
Est. primary completion date February 8, 2023
Accepts healthy volunteers No
Gender Female
Age group 18 Years to 80 Years
Eligibility Inclusion Criteria: Patients with clinical stage 1-2 endometrial cancer ASA 1-3 patients Exclusion Criteria: Patients with clinical stage 3-4 endometrial cancer Patients who are not suitable for robotic surgery due to their comorbidities (such as glaucoma, COPD, asthma) ASA 4-5 patients

Study Design


Related Conditions & MeSH terms


Intervention

Procedure:
indocyanine green
Cervical indocyanine green injection for the detection of sentinel lymph node

Locations

Country Name City State
Turkey Gökhan Demirayak Istanbul

Sponsors (1)

Lead Sponsor Collaborator
Bakirkoy Dr. Sadi Konuk Research and Training Hospital

Country where clinical trial is conducted

Turkey, 

References & Publications (4)

2- NCCN Clinical Practice Guidelines in Oncology. Uterine Neoplasms Version 4.2021 -September 3, 2021 https://www.nccn.org/professionals/physician_gls/pdf/uterine.pdf

Maramai M, Achilarre MT, Aloisi A, Betella I, Bogliolo S, Garbi A, Maruccio M, Quatrale C, Aletti GD, Mariani A, Colombo N, Maggioni A, Multinu F, Zanagnolo V. Cervical re-injection of indocyanine green to improve sentinel lymph node detection in endometr — View Citation

Siegel RL, Miller KD, Jemal A. Cancer statistics, 2020. CA Cancer J Clin. 2020 Jan;70(1):7-30. doi: 10.3322/caac.21590. Epub 2020 Jan 8. — View Citation

Yost KJ, Cheville AL, Al-Hilli MM, Mariani A, Barrette BA, McGree ME, Weaver AL, Dowdy SC. Lymphedema after surgery for endometrial cancer: prevalence, risk factors, and quality of life. Obstet Gynecol. 2014 Aug;124(2 Pt 1):307-315. doi: 10.1097/AOG.00000 — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Bilateral sentinel lymph node detection rate 1 year
See also
  Status Clinical Trial Phase
Recruiting NCT05437380 - Peritumoral Microbubbles and CEUS for SLN Detection and Biopsy in HNSCC N/A
Active, not recruiting NCT04303715 - No Axillary sUrgical Treatment In Clinically Lymph Node Negative Patients After UltraSonography N/A
Completed NCT05498051 - Fluorescent Sentinel Lymph Node Identification in Colon Carcinoma Using Submucosal Bevacizumab-800CW. N/A
Active, not recruiting NCT06169787 - Sentinel Lymph Nodes Biopsy in Cervical Cancer
Completed NCT03294330 - SPY-X: A Study to Assess the Feasibility of Using SPY Alone for Sentinel Node Localization for Melanoma or Breast Cancer Phase 3
Not yet recruiting NCT04930692 - A Prospective Single-center Cohort Study "Preoperative Identification of Sentinel Lymph Nodes Using Contrast-enhanced CT Lymphography in Breast Cancer Patients" N/A
Recruiting NCT03749707 - HPV in Sentinel Lymph Nodes N/A
Completed NCT03899441 - Multimedia Aid Gynecologic Counseling and Consent N/A
Recruiting NCT04826211 - Axillary Staging in Node Positive Breast Cancer Patients Receiving PST. SNB vs PET/MRI N/A
Not yet recruiting NCT06130241 - Sentinel Lymph Node Biopsy After Neoadjuvant Chemotherapy in Initially Node Positive Breast Cancer Patients, Could it Omit Axillary Dissection ? N/A
Recruiting NCT04664582 - Sentinel Lymph Node Biopsy for Cutaneous Squamous Cell Carcinoma of the Head and Neck N/A
Withdrawn NCT04487912 - Dynamics and Tracer Distribution of Tilmanocept in Early Stage Breast Cancer Phase 4
Completed NCT03563781 - SEntine Lymph Node in earLY Ovarian Cancer (SELLY) N/A
Recruiting NCT05623280 - Artificial Intelligence Analysis of Fluorescence Image to Intraoperatively Detect Metastatic Sentinel Lymph Node.
Active, not recruiting NCT05359783 - Sentinel Node Localization and Staging With Low Dose Superparamagnetic Iron Oxide Phase 1/Phase 2
Not yet recruiting NCT04568941 - Comparison Study of Different Tumor Biopsy Method for Sentinel Lymph Node Biopsy in Breast Cancer N/A
Completed NCT03606616 - Prospective Feasibility Study Applying the ACOSOG Z0011 Criteria to Chinese Patients
Recruiting NCT02982148 - Methylene Blue Intradermal Injection for Sentinel Lymph Node Biopsy for Breast Cancer Patients Phase 4
Recruiting NCT06161428 - Optical Guided Sentinel Node Biopsy for Staging of Vulvar Cancer
Completed NCT03900104 - Cervical and Endometrial Injection for Sentinel Lymph Node Detection in Endometrial Cancer N/A