Clinical Trials Logo

Clinical Trial Summary

Brief Summary: Main objective: Comparison of a tonotopy based fitting strategy (TFS) with fine structure coding to a tonotopy based fitting strategy without fine structure coding (TnoFS) for speech perception in noise. Secondary objectives: Comparison of TFS to TnoFS for the perception of musical elements (contour test). Comparison of TFS to TnoFS for speech perception in quiet Comparison of TFS to TnoFS for the qualitative preference for the listening of musical pieces. Comparison of TFS to TnoFS for the melodic recognition


Clinical Trial Description

Introduction: Cochlear implantation allows the rehabilitation of profound bilateral deafness, restoring speech perception and verbal communication when the traditional hearing aid no longer provides satisfactory hearing gain (Nimmons et al.). A cochlear implant includes an electrode array and its functioning is based on the principle of cochlear tonotopy: each electrode encodes a frequency spectrum according to its position in the cochlea (high frequencies are assigned to the basal electrodes and low frequencies to the apical electrodes). The cochlear implant thus breaks down the frequency spectrum into a number of frequency bands via bandpass filters corresponding to the number of electrodes in the implant. During the fitting these bands can be modified by the audiologist. The fitting software developed by the manufacturers proposed a default fitting with a lower limit between 100 and 250 Hz according to the brands and an upper limit of about 8500 Hz. The frequency bands assigned to each electrode follow a logarithmic scale with the high frequencies for the basal electrodes and the low frequencies for the apical electrodes. This distribution takes into account the number of active electrodes but does not take into account the anatomy and the natural cochlear tonotopy specific to each patient. Several studies have analyzed the anatomical variations of the cochlear dimensions: size of the cochlea and the ratio between the contact surfaces of the electrodes with the cochlea are variable from one patient to another (Stakhovskaya O et al., P. Pelliccia et al.). The insertion depth during surgery is also variable due to parameters related to the patients as well as to the operator, which seems to impact the understanding of speech in noise (Deep electrode insertion and sound coding in cochlear implants - Ingeborg Hochmair et al.). Mathematical algorithms have recently been developed to estimate the cochlear tonotopy of each patient from a CT scan assessment (Jiam et al., Sridhar et al.). CT imaging of the implanted ear combined with 3D reconstruction software, provides cochlear length measurements (Cochlear length determination using Cone Beam Computed Tomography in a clinical setting - Würfel et al .). Using this approach it is possible to measure the position of each electrode relative to the cochlear apex. These measurements are applied to the modified Greenwood equation to obtain the tonotopic frequency for each electrode and to determine for each patient a fitting based on the tonotopy of each electrode. Conventional stimulation strategies in cochlear implants (e.g. advanced combination encoder (ACE), continuous interleaved sampling (CIS)) use the place of the electrode to code the frequency by sending low frequency information on the apical electrodes and high frequency information on the basal electrodes. The stimulation rate of the electrodes is constant. The pitch is only partially transmitted by these conventional strategies which would explain the poor results of cochlear implants in the perception of music. In the FineHearing strategy of the MED-EL implant, the rate of stimulation on the low-frequency electrodes is related to the frequency of the sound and makes it possible to code the frequency information temporally. Rader & al. 2016 have studied the contribution of adding to the tonotopic coding of the frequency (classical strategy) a temporal coding of the information by varying the stimulation rate. The results obtained show that providing this frequency information by time coding makes it possible to obtain perceived pitch much closer to the expected pitch (of normal-hearing) and less variability, especially at low frequencies. With fixed stimulation rate (classical strategy) low frequencies are poorly coded, whereas with the variable stimulation rate they are better coded. In addition, Landsberger et al. [2018] studied in six subjects with a MED-EL implant the perception of a temporal coding according to the position of the electrodes with a long insertion: middle or apical position. The results seem to show that the temporal coding of the frequency would be more reliable than the spatial coding (related to the position of the electrode) at the apex, and the reverse on the electrodes in the middle position. Studies have shown that the FineHearing strategy can provide benefits over the classic High-Definition Continuous Interleaved Sampling (HDCIS) strategy in tasks involving the fundamental F0 such as speech recognition in noise (after a certain learning time) [Kleine Punte & al. 2014 ; Vermeire & al. 2010], the perception of music [Roy & al. 2015 ; Roy & al. 2016] or the perceived quality of pitch [Müller & al. 2012]. MED-EL's FineHearing coding strategy with a tonotopic-based fitting could therefore allow better transmission of pitch and in particular improve the speech recognition in noise compared to the same tonotopic-based fitting without FineHearing coding. Main objective: Comparison of a tonotopy based fitting strategy (TFS) with fine structure coding to a tonotopy based fitting strategy without fine structure coding (TnoFS) for speech perception in noise. Secondary objectives: Comparison of TFS to TnoFS for the perception of musical elements (contour test). Comparison of TFS to TnoFS for speech perception in quiet Comparison of TFS to TnoFS for the qualitative preference for the listening of musical pieces. Comparison of TFS to TnoFS for the melodic recognition Plan of the study: It is a prospective open monocentric randomized crossover study: measures will be done on the patient at 6 weeks and 12 weeks post-activation. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05754918
Study type Interventional
Source MED-EL Elektromedizinische Geräte GesmbH
Contact Vincent Péan, PhD
Phone 603592974
Email vincent.pean@medel.com
Status Recruiting
Phase N/A
Start date April 15, 2023
Completion date December 1, 2024

See also
  Status Clinical Trial Phase
Recruiting NCT05621798 - Quantifying the Benefits and Cost-effectiveness of Real-Ear Measurements (REM) for Hearing Aid Fitting N/A
Completed NCT04571333 - Feasibility of the Mi2000 Totally Implantable Cochlear Implant in Severely to Profoundly Deaf Adults. N/A
Recruiting NCT05821959 - Gene Therapy Trial for Otoferlin Gene-mediated Hearing Loss Phase 1/Phase 2
Completed NCT04777565 - Study of a Minimally Invasive Cochlear Access for Cochlear Implantation Via a Robotic Procedure N/A
Not yet recruiting NCT05154188 - Post Approval Study to Assure the ContInued saFety and effectIveness of Neuro Cochlear Implant System in Adult Users
Completed NCT03304106 - Clinical Investigation of New CI Delivery Models in an Adult Nucleus CI Population N/A
Recruiting NCT05898659 - Comparison in New Cochlear Implanted Subjects of a Tonotopy-based Bimodal Fitting With or Without Synchronization N/A
Recruiting NCT05955469 - Comparison in New Cochlear Implanted Subjects of a Tonotopy-based Bimodal Fitting and a Conventional Fitting N/A
Completed NCT04145661 - Non-linear Frequency Compared to Conventional Processing in Patients With and Without Cochlear Dead Regions. N/A
Recruiting NCT05402813 - Natural History in Children up to 10 Years With Moderate to Profound Hearing Loss Due to Mutations in GJB2 / OTOF Genes
Not yet recruiting NCT06354010 - Cross-sectional and Prospective Study to Characterize Early-onset Presbycusis
Completed NCT02755935 - CI532 - Early Experience Study N/A
Completed NCT04469946 - Hearing Aid Noise Reduction in Pediatric Users Pilot Study (Oticon Pilot Study) N/A
Recruiting NCT05369598 - Audiological and Quality of Life Outcomes of Anatomy Based Fitting in Patients Implanted by Robot Assisted Cochlear Implant Surgery (RACIS) N/A
Completed NCT04922619 - Study of Music and Speech Perception in New Cochlear Implanted Subjects Using or Not a Tonotopy Based Fitting N/A
Recruiting NCT05572073 - Otoferlin Gene-mediated Hearing Loss Natural History Study
Recruiting NCT04591093 - Auditory Performances With Different Stimulation Depths in Cochlear Implanted Subjects Using a Fine Structure Strategy N/A
Completed NCT03993899 - Study of Quality Perception on Music in New Cochlear Implanted Subjects Using or Not a Fine Structure Strategy N/A
Withdrawn NCT03694704 - Study of Auditory Performance on Prosodic Tests in Cochlear Implanted Subjects Using a Fine Structure Strategy N/A
Terminated NCT03904420 - An Evidence Based Delivery Model of Care for Newly Implanted Adult CI Recipients N/A