Clinical Trials Logo

Clinical Trial Summary

Rapid antigen detection (RAD) tests are used to perform rapid diagnosis of SARS-CoV-2 infection based on a qualitative approach. RAD tests detect the viral antigen by the immobilized coated SARS-CoV-2 antibody placed on the device. The results of these tests are available in a short time, reducing the workload in diagnostic hospitals and laboratories and improving the turn-around time. EuGeni SARS-CoV-2 Antigen Rapid Diagnostic Test is an in vitro Diagnostic (IVD) medical device intended to be used for the qualitative detection of SARS-CoV-2 nucleocapsid antigen. The result from this IVD test identifies the presence or absence of the SARS-CoV-2 antigen as an aid for the diagnosis of COVID-19 infection.


Clinical Trial Description

The EuGeni SARS-CoV-2 Antigen (Ag) Rapid Detection Test (RDT) is a test strip based on lateral flow technology which utilizes nanoparticles, doped with europium, as the fluorescence reporter system. The test strip is housed in a cassette which is read by the EuGeni AX-2X-S Reader, a portable instrument that reads EuGeni fluorescent lateral flow tests. The test line contains an immobilized monoclonal mouse antibody to capture SARS-CoV-2 antigen and the control line contains an immobilized control anti-mouse antibody. The test sample is added to the sample well of the test cassette and then reconstitutes the dried europium nanoparticle antibody conjugate from the conjugate pad. The sample flows along the test strip by capillary action. If the sample contains SARS-CoV-2 antigen, it binds to the antibody-labelled europium nanoparticle. When the sample flows past the test line, the europium bound antigen is captured by the second anti-SARS-CoV-2 antibody immobilized on the test line. A fluorescent signal detected by the EuGeni AX-2X-S Reader at this test line indicates that the specimen is SARS-CoV-2 antigen Positive. If the sample does not contain SARS-CoV-2 antigen, the europium-labelled anti-antigen antibody will not bind to the test line. This indicates that the specimen is SARS-CoV-2 antigen Negative. The sample continues to flow along the strip and when it passes over the control line, antibody-labelled europium nanoparticles are captured by the immobilized anti-mouse antibody. The control line must be detected by the EuGeni AX-2X-S Reader for the test to be valid. If the control line is not detected, the test is considered invalid and must be repeated using another test cassette. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05618561
Study type Observational
Source AnteoTech Ltd
Contact
Status Terminated
Phase
Start date July 26, 2022
Completion date November 2, 2022

See also
  Status Clinical Trial Phase
Terminated NCT04555096 - A Trial of GC4419 in Patients With Critical Illness Due to COVID-19 Phase 2
Completed NCT04593641 - This is a Phase 1 Study to Evaluate the Safety,Tolerability and Virology of CT P59 in Patients With Mild Symptoms of Symptoms of Coronavirus Disease (COVID-19) Phase 1
Recruiting NCT05200754 - Trial With or Without Infusion of SARS-CoV-2 Antibody Containing Plasma in High-Risk Patients With COVID-19 Phase 2
Completed NCT04583995 - A Study Looking at the Effectiveness, Immune Response, and Safety of a COVID-19 Vaccine in Adults in the United Kingdom Phase 3
Recruiting NCT06255860 - SARS-COV-2 Reinfection and Multisystem Inflammatory Syndrome in Children (MIS-C) Risk: Matched Case-control Study
Recruiting NCT04516811 - Therapeutic Use of Convalescent Plasma in the Treatment of Patients With Moderate to Severe COVID-19 Phase 3
Recruiting NCT05012826 - Osteopathy and Physiotherapy Compared to Physiotherapy Alone on Fatigue and Functional Status in Long COVID N/A
Completed NCT05007236 - Study to Evaluate the Efficacy and Safety of Oral RP7214, a DHODH Inhibitor, in Patients With Symptomatic Mild COVID-19 Infection. Phase 2
Recruiting NCT06026514 - Phase I Safety Study of B/HPIV3/S-6P Vaccine Via Nasal Spray in Adults Phase 1
Completed NCT05523739 - Safety and Efficacy Study of STI-1558 in Healthy Adults and SARS-CoV-2-Positive Patients Phase 1
Suspended NCT04738136 - Safety, Tolerability and Efficacy Of S-1226 in Moderate Severity Covid-19 Bronchiolitis/Pneumonia Phase 2
Recruiting NCT04584658 - Dysphagia and Dysphonia Outcomes in SARS CoV-2 (COVID-19) Infection (DYADS Study)
Recruiting NCT04547114 - Breath Analysis for SARS-CoV-2 in Infected and Healthy Subjects
Completed NCT05119348 - Transmission of Coronavirus Disease 2019 (COVID19) in Crowded Environments N/A
Completed NCT05096962 - COVID-19: SARS-CoV-2-CZ-PREVAL-II Study
Recruiting NCT04534400 - Automated Quantification of Radiologic Pulmonary Alteration During Acute Respiratory Failure
Completed NCT04527354 - Pilot Study to Assess Efficacy and Safety of Treamid in the Rehabilitation of Patients After COVID-19 Pneumonia Phase 2
Completed NCT04583982 - ImmuneSense™ COVID-19 Study
Completed NCT05077176 - Phase 3 Booster Vaccination Against COVID-19 Phase 3
Completed NCT05584189 - COVID-19 MP Biomedicals Rapid SARS-CoV-2 Antigen Test Usability N/A