View clinical trials related to Resuscitation.
Filter by:A prospective, multicenter, randomized clinical trial in two tertiary pediatric emergency department. It will assess, amongst pediatric healthcare teams, whether the use of augmented reality supportive devices improves adherence to American Heart Association (AHA) advanced life support guidelines and performance, while reducing medication errors, when compared to groups using the AHA pocket reference card (control) during standardized, simulation-based, pediatric in-hospital cardiac arrest (IHCA) scenarios. Seventy participants will be randomized. The primary endpoint is the time to first dose of epinephrine.
Background: This study, in contrast to the previous studies, generated a scenario of fatigue in an earthquake scenario and aimed to measure the effect of fatigue on the quality of cardiopulmonary resuscitation (CPR) performed by paramedics in a debris course. Methods: The study was designed as a randomized controlled trial. The sample, consisting of 84 paramedic students, was randomly assigned as 42 control and 42 experimental groups. Fatigue was created in the participants by rehearsing the process of removing and transporting earthquake victims from the rubble through the prepared track. A personal information form and a CPR measurement form were used to obtain the data. The simulator was used to evaluate the accuracy of CPR. The collected data were analysed with the statistical program.
Positive pressure ventilation (PPV) is the most important intervention in neonatal resuscitation. During PPV, it is important to hold the face-mask with care, as applying excessive pressure could cause injury to the infant, while insufficient pressure could be a contributor of mask leak and reduced effective ventilation. Application of positive pressure to face structures may trigger a vagally mediated reflex via the trigeminal nerve that innervates the skin of the face leading to apnoea and a decrease in heart rate (TCR, trigeminal-cardiac reflex). The force exerted by providers during neonatal ventilation to improve mask seal might result in pressure lesions and the elicitation of the trigeminal-cardiac reflex. The height of the resuscitation could influence the forces applied to the face and the quality of the procedure. Information about the applied forces in relation to the height of the resuscitation table is unknown.
In this retrospective study, the investigators seek to investigate the incidence of pneumothorax following possible risk factors, and elucidate its association with outcomes.
The aim of this study is to compare the effect of resuscitation guided by Left ventricular outflow tract-velocity time integral (LVOT-VTI) variation versus the effect of resuscitation guided by inferior vena cava (IVC) variation on time to normalization of the capillary refill time in adult patients with septic shock, amount of resuscitation fluids, rate of vasopressor and ICU length of stay.
This study evaluates the effectiveness of CPR during via ferrata rescues, focusing on response quality and outcomes in challenging outdoor settings.
Incidence of the background information, incidence and special characteristics of out- and in-hospital cardiac arrest at a tertiary hospital in Germany.
Airway management in out-of-hospital cardiac arrest is still debated. Several options exist: bag-valve-mask ventilation, supraglottic devices and endotracheal intubation. Intermediate and advanced airway management strategies could be useful devices to increase chest compression fraction. A previous study shows that early insertion of an i-gel device significantly increases chest compression fraction and enhances respiratory parameters. However, the compressions were found to be shallower in the experimental group using the i-gel device. Although, the shallower compressions found in the supraglottic airway device group did not appear to be linked to their provision in an over-the-head position, it is reasonable to assume that the addition of a feedback device to the use of an i-gel® device could fix this issue. The feedback devices seem to be able to provide a benefit, and allow deeper compressions / more often in the depth target. There is a mismatch between perceived and actual cardiopulmonary resuscitation performance supporting the need for such a feedback device's study.
Intrapartum asphyxia and prematurity are the leading causes of neonatal mortality in low and middle income countries. Neonatal resuscitation training reduces asphyxia-related newborn mortality and morbidity, but in the absence of continuing low-dose, high frequency practice, these initial gains rapidly decay. The investigators propose to develop and evaluate innovative mobile virtual simulations for refresher training on neonatal resuscitation and essential newborn care to support the retention of knowledge and skills among health care workers in low and middle income countries.
Pediatric cardiac arrest occurs most in the prehospital setting. Most of them are due to respiratory failure (e.g., trauma, drowning, respiratory distress), where hypoxia leads to cardiac arrest. Generally, emergency medical services (EMS) first use basic airway management techniques i.e., the use of a bag-valve-mask (BVM) device, to restore oxygenation in pediatric OHCA victims. However, these devices present many drawbacks and limitations. Intermediate airway management, i.e., the use of SGA devices, especially the i-gel® has several advantages. It has been shown to enhance both circulatory and ventilatory parameters. There is increasing evidence that IAM devices can safely be used in children. In two pediatric studies of OHCA, American paramedics had significantly higher success rates with SGA devices than with TI. A neonatal animal model showed that the use of SGA was feasible and non-inferior to TI in this population. However, data regarding the effect of IAM with an i-gel® versus the use of a BVM on ventilation parameters during pediatric OHCA is missing. The hypothesis underlying this study is that, in case of pediatric OHCA, early insertion of an i-gel® device without prior BVM ventilation should improve ventilation parameters in comparison with the standard approach consisting in BVM ventilations.