Clinical Trial Summary

An observational study will be conducted in 20 hospitalized surgical patients routinely managed with opioids for anesthesia and post-operative pain control. Trachea Sound Sensor measurements and reference respiratory measurements will be recorded and analyzed to develop diagnostic algorithms that produce a risk-index score that detects/predicts progression from mild hypoventilation, to moderate hypoventilation, to severe hypoventilation due to opioids and other medications that cause respiratory depression. Our current Trachea Sound Sensor (TSS) has a wired Sony commercial microphone integrated into a commercial pediatric stethoscope, coupled to the skin surface over the trachea at the sternal notch. The Trachea Sound Sensor will measure and record the sounds of air moving within the proximal trachea during inhalation and exhalation. The microphone signal will be converted into an accurate measurement of the patient's respiratory rate and tidal volume (during inhalation & exhalation) over time, to determine the minute ventilation trend, breathing patterns, apnea episodes, and degree of snoring (due to partial upper airway obstruction). A commercial respiratory facemask and two pneumotachs (gas flow sensors) will also be used to accurately and continuously measure the patient's respiratory rate and tidal volume (during inhalation & exhalation) to determine the minute ventilation trend, breathing patterns, and apnea episodes. TSS data and reference respiratory data will be collected prior to surgery with the patient breathing normally (baseline), in the Operating Room (OR) during the induction and maintenance of anesthesia, in the Post Anesthesia Care Unit (PACU), and on the general nursing floors of Thomas Jefferson University Hospital (TJUH). The sounds of air flowing through the proximal trachea will be correlated with the reference breathing measurements using signal processing methods to optimize the measurement accuracy of RR, TV, breathing pattern, apnea episodes, and degree of snoring. A commercial accelerometer may be coupled to the skin surface of the neck (with tape) to measure body position and activity level. The TSS and vital sign trend data will be analyzed to produce a Risk-Index Score every 30 seconds with alerts and alarms that warn the patient and caregivers about progressive Opioid Induced Respiratory Depression (OIRD).


Clinical Trial Description

RTM's Trachea Sound Sensor (TSS) and data acquisition system will be used to measure and record the sounds of air movement within the trachea during inhalation/exhalation prior to surgery (baseline), and during management with opioid medications in the operating room (OR), post-anesthesia care unit (PACU), intensive care unit (ICU), and/or general nursing floor. The TSS will be adhered to the skin of the neck (within the sternal notch) to measure and record the sounds of air flowing through the proximal trachea during inhalation and exhalation. A commercial miniature accelerometer sensor may also be adhered to the skin of the neck and used to measure and record the patient's body position and activity level. In addition, research staff will intermittently measure and record each patient's respiratory rate (RR) and tidal volume (TV) prior to surgery (baseline), during anesthesia (OR), during anesthesia recovery (PACU), and during post-operative care (ICU or nursing floor) using a commercial research facemask and respiratory flow sensors (pneumotachs) hardwired to a data acquisition system and personnel computer (PC). One commercial pneumotach will accurately measure the patient's tidal volume during inhalation, and another commercial pneumotach will accurately measure the patient's tidal volume during exhalation. The concentration of oxygen in the inspired air delivered into the facemask will be tightly controlled, according to a physician's order and standard-of-care methods. The facemask and commercial ventilation measurement system was designed and tested in collaboration with Nick Rudolph from the company Hans Rudolph, Inc. Capnography will also be used to continuously measure and record the concentration of carbon dioxide within the facemask's air during inhalation and exhalation, using end-tidal measurements to estimate the concentration carbon dioxide in the alveoli and arterial blood. Hemoglobin oxygen saturation will be continuously measured and recorded using a commercial pulse oximeter and finger probe. In some of the study subjects, blood will be intermittently sampled from a radial artery catheter (previously inserted for clinical care) or a peripheral venous catheter and used to measure the levels of pH, oxygen, carbon dioxide, lactate and other analytes using a point-of- care meter. Blood may be sampled more frequently before and after an opioid bolus or a change in opioid dose. Blood will not be sampled from some of the study subjects because a radial artery/venous catheter were not available or functional for blood sample acquisition. Trend data will be used to develop a diagnostic algorithm with a risk-index score that detects/predicts progression from mild hypoventilation, to moderate hypoventilation, to severe hypoventilation due to opioids ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05506267
Study type Observational
Source Thomas Jefferson University
Contact
Status Completed
Phase
Start date June 1, 2020
Completion date April 30, 2022

See also
  Status Clinical Trial Phase
Recruiting NCT05904652 - High Flow Nasal Oxygen at Extubation for Adults Requiring a Breathing Tube for Treating Severe Breathing Difficulties N/A
Completed NCT04030208 - Evaluating Safety and Efficacy of Umbulizer in Patients Requiring Intermittent Positive Pressure Ventilation N/A
Recruiting NCT03697785 - Weaning Algorithm for Mechanical VEntilation N/A
Recruiting NCT02989051 - Fluid Restriction Keeps Children Dry Phase 2/Phase 3
Completed NCT02930525 - Effect of High Flow Nasal Cannula vs. Standard Care on Respiratory Stability in Pediatric Procedural Sedation N/A
Recruiting NCT02539732 - Prediction of Outcome of Weaning From Mechanical Ventilation Using the Electrical Activity of the Diaphragm
Enrolling by invitation NCT02290236 - Monitored Saturation Post-ICU N/A
Completed NCT02056119 - RCT of Mesh Versus Jet Nebulizers on Clinical Outcomes During Mechanical Ventilation in the Intensive Care Unit N/A
Terminated NCT01583088 - Early Stage Amyotrophic Lateral Sclerosis Phrenic Stimulation Phase 3
Withdrawn NCT00990119 - High Flow Therapy (HFT) to Treat Respiratory Insufficiency in Chronic Obstructive Pulmonary Disease (COPD) N/A
Completed NCT00741949 - Broncho-alveolar Lavage Under Noninvasive Ventilation With Propofol TCI in Patient With AHRF Phase 3
Completed NCT01411722 - Electrical Activity of the Diaphragm During the Weaning Period Phase 2
Recruiting NCT00339053 - Immunonutrition and Thoracoabdominal Aorta Aneurysm Repair Phase 4
Recruiting NCT00187434 - Comparison of Two Methods of Continuous Positive Airway Pressure (CPAP) to Support Successful Extubation of Infants of Birth Weights ≤ 1500 Grams (C2CPAP) N/A
Completed NCT02687802 - Respiratory Mechanics and Patient-ventilator Asynchrony Index in Patients With Invasive Mechanical Ventilation
Not yet recruiting NCT05906030 - Diaphragm Dysfunction and Ultrasound Perioperatively
Completed NCT03850977 - Is There an Association Between Chronic Pancreatitis and Pulmonary Function
Completed NCT02845375 - Effect of Neuromuscular Blockade and Reversal on Breathing Phase 4
Recruiting NCT03309423 - Is Venous to Arterial Conversion (v-TAC) of Blood Gas Reliable in Critical Ill Patients in the ICU? N/A
Completed NCT04115969 - Outcome After Non-invasive Ventilation.