Clinical Trials Logo

Clinical Trial Summary

Patients who develop respiratory failure require the assistance of mechanical ventilation while recovering from their respiratory injury. For example, patients that are affected by COVID-19 can develop such severe respiratory failure that they are unable to breathe on their own and therefore require the assistance of a mechanical ventilator. A Bronchoscope is a tool that can be used to visualize the inside of the lungs to aid in further diagnosis and delivery of therapeutic agents in patients with respiratory disease or failure. However, bronchoscopy can cause air to leak from the patient's lungs into the room due to a poorly designed adapter that is required to facilitate the introduction of the bronchoscope into the lungs. This leak can lead to the patient losing oxygen during the procedure which can be harmful to the patient and delay or limit recovery. Additionally, the air that leaks can lead to the spread of bacteria/viruses into the ambient air, which can contaminate the intensive care unit and expose other patients and healthcare workers to harmful pathogens. This was highlighted most recently during the COVID-19 pandemic where national guidelines limited the use of bronchoscopy in patients affected by the virus due to concerns about spreading the virus within the hospital and to the healthcare workers. In this study, the investigators will evaluate the efficacy of a novel adapter that avoids air leakage during bronchoscopy. Patients with respiratory failure on mechanical ventilation who require bronchoscopy will be randomized into two groups (groups A and B). These patients will be identified by the intensive care unit physician. Informed consent will be obtained from the patient's health care proxy. Patients in group A will undergo bronchoscopy using the standard commercially available adapter. Patients in group B will undergo bronchoscopy using the newly developed bronchoscope adapter. The efficacy of the bronchoscopy adapter will be evaluated by analyzing ventilator-associated parameters as well as the level of air contamination after the procedure. A bronchoscope adapter that limits air leak would have significant value in improving patient outcomes who receive bronchoscopy. Additionally, this would allow bronchoscopy to be more readily performed in patients with potential bacterial/viral pathogen spread. Primary objective: Determination of equivalency or superiority of the new "leak-free adapter" compared to the standard commercial adapter to enable safe bronchoscopy in ventilated patients requiring bronchoscopy. Secondary objective: To determine if the adapter provides improved ventilation during bronchoscopy by limiting tidal volume loss and pathogen aerosolization.


Clinical Trial Description

Patients who develop acute respiratory failure require hospitalization and mechanical ventilatory support. Of all patients admitted to intensive care units in the US, approximately 40% require mechanical ventilation. With the ongoing COVID-19 pandemic, approximately 18% of affected patients are expected to require mechanical ventilation. Mechanical ventilation requires endotracheal intubation (cannulation of the patient's trachea) to deliver ventilated air to the lungs. Air is delivered by the ventilator to the patient using positive pressure in a closed circuit, ensuring adequate tidal volume to the patient without air escape to the outside environment. Nevertheless, patients placed on mechanical ventilation often develop superimposed infections known as "Ventilator-Associated Pneumonia" (VAP) as well as significant mucus secretions which limit effective mechanical ventilation. A camera tipped device is used to enable more effective bronchoscopy to visualize and explore the tracheobronchial tree for both diagnostic (bacterial/viral sampling) and therapeutic (suctioning obstructive mucus secretions, delivery of therapeutic agents) purposes. Despite clear diagnostic and therapeutic benefits, bronchoscopy is also associated with substantial morbidity and complications. To perform bronchoscopy, a standard (commercially available) adapter allows the bronchoscope to enter the closed ventilation circuit, providing direct access to the patient's airways. However, the standard adapter leads to a significant leak of tidal volume outside of the ventilation circuit to the ambient environment. This air leak from the adapter leads to two major complications: First, the loss of positive pressure ventilation to patients means that oxygen is not being delivered to the patient and therefore leads to hypoxemia, which limits the duration and efficacy of bronchoscopy. Second, escaped air from the ventilator circuit can lead to the generation of aerosols, which can lead to the significant spread of viral and bacterial infectious agents to the ambient environment and surrounding healthcare providers. Intensive care units (ICUs) in the US must employ negative pressure ventilation to limit pathogen spread outside of the room and to the rest of the ICU. ICU rooms equipped with standard room negative pressure ventilation require 46 minutes after bronchoscopy to clear 99% of aerosolized pathogens. Thus, despite the known diagnostic and therapeutic benefits of bronchoscopy, concerns surrounding viral exposure related to an air leak from bronchoscopy adapters led to the development of national guidelines that limited bronchoscopy in patients affected by Covid-19. To overcome these limitations, the investigators developed a novel bronchoscope adapter capable of effectively limiting all tidal volume loss (i.e., air leak via adapter) associated with the currently available standard adapters. In ex-vivo and animal studies, the investigators noted that a significant portion of tidal volume delivered by the ventilator is lost to the ambient air when using the standard bronchoscope adapter using the standard adapter (~40%). There was no tidal volume loss associated with the Leak-free bronchoscope adapter. The innovation in this adapter's development lies in the capacity to form an improved seal around the bronchoscope that limits tidal volume loss around the bronchoscope and captures air that escapes the circuit with the insertion and removal of the bronchoscope. Of note, the adapter is positioned outside the circuit and is only a conduit for the bronchoscope to enter the circuit. Here the investigators propose a comparative effectiveness study that evaluates the leak-free bronchoscope adapter's use to enable bronchoscopy similar to the standard adapter. Additionally, the investigators will evaluate the adapter's capacity to deliver either equivalent tidal volume to the currently available adapter in patients undergoing bronchoscopy. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05288218
Study type Interventional
Source Columbia University
Contact
Status Withdrawn
Phase N/A
Start date May 2023
Completion date June 2024

See also
  Status Clinical Trial Phase
Recruiting NCT05904652 - High Flow Nasal Oxygen at Extubation for Adults Requiring a Breathing Tube for Treating Severe Breathing Difficulties N/A
Completed NCT04030208 - Evaluating Safety and Efficacy of Umbulizer in Patients Requiring Intermittent Positive Pressure Ventilation N/A
Recruiting NCT03697785 - Weaning Algorithm for Mechanical VEntilation N/A
Recruiting NCT02989051 - Fluid Restriction Keeps Children Dry Phase 2/Phase 3
Completed NCT02930525 - Effect of High Flow Nasal Cannula vs. Standard Care on Respiratory Stability in Pediatric Procedural Sedation N/A
Recruiting NCT02539732 - Prediction of Outcome of Weaning From Mechanical Ventilation Using the Electrical Activity of the Diaphragm
Enrolling by invitation NCT02290236 - Monitored Saturation Post-ICU N/A
Completed NCT02056119 - RCT of Mesh Versus Jet Nebulizers on Clinical Outcomes During Mechanical Ventilation in the Intensive Care Unit N/A
Terminated NCT01583088 - Early Stage Amyotrophic Lateral Sclerosis Phrenic Stimulation Phase 3
Withdrawn NCT00990119 - High Flow Therapy (HFT) to Treat Respiratory Insufficiency in Chronic Obstructive Pulmonary Disease (COPD) N/A
Completed NCT00741949 - Broncho-alveolar Lavage Under Noninvasive Ventilation With Propofol TCI in Patient With AHRF Phase 3
Completed NCT01411722 - Electrical Activity of the Diaphragm During the Weaning Period Phase 2
Recruiting NCT00339053 - Immunonutrition and Thoracoabdominal Aorta Aneurysm Repair Phase 4
Recruiting NCT00187434 - Comparison of Two Methods of Continuous Positive Airway Pressure (CPAP) to Support Successful Extubation of Infants of Birth Weights ≤ 1500 Grams (C2CPAP) N/A
Completed NCT02687802 - Respiratory Mechanics and Patient-ventilator Asynchrony Index in Patients With Invasive Mechanical Ventilation
Not yet recruiting NCT05906030 - Diaphragm Dysfunction and Ultrasound Perioperatively
Not yet recruiting NCT05508724 - Recruitment Manoeuvres in Critically Ill Patients
Completed NCT03850977 - Is There an Association Between Chronic Pancreatitis and Pulmonary Function
Completed NCT02845375 - Effect of Neuromuscular Blockade and Reversal on Breathing Phase 4
Recruiting NCT03309423 - Is Venous to Arterial Conversion (v-TAC) of Blood Gas Reliable in Critical Ill Patients in the ICU? N/A