Clinical Trials Logo

Clinical Trial Summary

The study objective is to assess patient satisfaction after the surgery with a custom-made CE marked implant (ORIGIN®) versus off-the-shelf (VANGUARD PS) device, and to document the clinical and device performance outcomes of the ORIGIN System used in routine hospital practice in a large patient cohort treatment of total knee arthroplasty. The hypothesis is that patients receiving ORIGIN implants will experience a more natural feel of the prosthesis during the first year after the surgery compared to patients receiving VANGUARD implants (as measured with FJS), and slightly significant improvement at the following interval of 2 years. The overall patient satisfaction is expected to be improved after 2 years follow-up. It is also supposed that the overall patient satisfaction is expected to be higher with ORIGIN PS than with VANGUARD PS treatment.


Clinical Trial Description

ORIGIN® PS and VANGUARD® PS are total knee prostheses, intended to be used in primary Total Knee Replacement Arthroplasty (TKA). With the ORIGIN® PS implant being customized individually made (CIM) fitting a patient's anatomy, a more natural reconstruction of knee kinematics is anticipated and ultimately a higher patient satisfaction and lower revision rate are envisioned. To date literature providing data about CIM TKA is still scarce. A study assessing kinematics after TKA found that CIM TKA more closely resembled natural knee kinematics when compared to standard off-the-shelf (OTS) TKA. This resemblance allows for a more natural femoral rollback during knee flexion, the authors found. CIM TKA demonstrates knee kinematics more similar to a normal knee studying tibiofemoral kinematics using mobile fluoroscopy in vivo. Furthermore, CIM TKA has shown to provide a more accurate tibial fit and rotation, when compared to several standard TKA. A retrospective review of 621 TKA patients, 307 with CIM TKA and 314 with conventional implants, demonstrated a decreased estimated blood loss, decreased length of stay, decreased range of motion, and no discernible difference in surgical or tourniquet time. Albeit, the differences found were not deemed clinically relevant, the study underlined the safety and efficacy of the CIM TKA technique. Patients who received CIM TKA had lower transfusion rates and fewer adverse events. Four year data from the UK National Joint Registry showed a cumulative percent revision rate of 0.5% for CIM TKA versus a cumulative percent revision rate of 1.9% for all TKA. While all this data is encouraging, randomized controlled studies and assessments of patient reported outcomes are missing. Therefore, the current study aims to close this knowledge gap and provide Level I evidence for CIM TKA by comparing the two TKA Prostheses mentioned above and to evaluate their clinical performance and safety. This is a prospective, comparative, randomized, double arm, monocentric, observational, post-market study. The study is performed in Germany, in the University Medical Center of Johannes Gutenberg-University Mainz (UMC-Mainz). It is stated that 140 subjects implanted with either the ORIGIN PS or VANGUARD PS System will be included upon eligibility assessment. Subjects will be followed at one and two years after the procedure. Enrollment will occur at the time of the medical examination. It is assumed that the subjects' treatments and follow-up visits will be performed per standard of the investigational site in Germany. It is anticipated that enrollment will take approximately 18 months. As each implanted subject is to be followed for two years, the estimated study duration is approximately 48 months, excluding the time required for preparing the final report. (A loss of approximately 10% is expected at the end of the study) ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04728542
Study type Observational
Source Symbios Orthopedie SA
Contact Lukas Eckhard
Phone +49 6131-177302
Email Lukas.Eckhard@unimedizin-mainz.de
Status Recruiting
Phase
Start date March 25, 2021
Completion date November 2024

See also
  Status Clinical Trial Phase
Completed NCT00762944 - Total Temporomandibular Joint Replacement System Post Approval Study
Not yet recruiting NCT05015101 - Evaluation of the Clinical and Radiological Outcome of Uncemented Femoral Stems According to Their Proximal Coating
Terminated NCT02713906 - Materialise X-ray Knee Guides for Total Knee Arthroplasty N/A
Completed NCT02554149 - Radiological Measurement of Femoral Stem Version Using Lateral Decubitus Method: A Prospective Study N/A
Recruiting NCT02828293 - Understanding GMK Sphere Implant Tibiofemoral Kinematics by Means of Dynamic Videofluoroscopy
Completed NCT02829866 - AMIStem-H Radiographic Analysis
Terminated NCT00683267 - Efficacy and Safety Study of 4975 in Patients Undergoing Total Hip Replacement Phase 2
Completed NCT04516239 - Comparison of Metal on Metal Total Hip Arthroplasty and Metal on Metal Total Hip Resurfacing. Phase 4
Not yet recruiting NCT06323980 - INHANCE Stemless Reverse Shoulder IDE N/A
Recruiting NCT04480320 - Sonography-guided Pericapsular Never Group Block for Hip Arthroplasty N/A
Not yet recruiting NCT04906681 - Implementation of a Rehabilitation Technology in Orthopedic and Neurological Rehabilitation to Increase Therapy Dosage: an Exploratory Study Phase 1/Phase 2
Completed NCT04403919 - Knotless Suture in Revision Total Joint Arthroplasty N/A
Completed NCT03132831 - Influence of the Operative Day on the Average Duration of Stay in Primary Hip and Knee Replacements
Active, not recruiting NCT03339557 - Comparison of Three Knee Replacements N/A
Active, not recruiting NCT02578446 - Uncemented Tritanium Compared With Cemented Metal-backed Tibia Components in Total Knee Replacement N/A
Not yet recruiting NCT00756483 - Stability Plus - Outcomes From Extended Continuum of Care N/A
Terminated NCT00364533 - A Study to Evaluate the Effectiveness and Safety of Tapentadol(CG5503) in the Treatment of Acute Pain After Hip Replacement Surgery Compared With Oxycodone and Placebo Followed by a Voluntary Open-Label Extension For Safety Phase 3
Terminated NCT04089371 - A Post-Market Clinical Evaluation of the ReUnion Reversible Fracture (RFX) System
Completed NCT05248854 - Effects of Sensorimotor and Core Stabilization Exercises After Total Knee Arthroplasty N/A
Not yet recruiting NCT02465684 - Effect of Tourniquet on UKA N/A